Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study

被引:0
|
作者
Gupta, Khushbu Rakesh [1 ]
Gupta, Deepesh Kumar [1 ]
Jha, Anumeha [1 ]
Shukla, Shivam B. [1 ]
Dubey, Aayush Mukund [2 ]
机构
[1] Govt Dent Coll & Hosp, Dept Oral & Maxillofacial Prosthodont & Implantol, Raipur, Chhattisgarh, India
[2] Univ Cincinnati, Coll Med, Dept Epidemiol, Cincinnati, OH USA
来源
关键词
Endocrown; marginal fit; ferrule; CAD-CAM; intraoral scanner;
D O I
10.4103/jips.jips_207_24
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims:To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.Settings and Design:Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.Materials and Methods:Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.Statistical Analysis:The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P <= 0.05.Results:In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.Conclusions:Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [41] Comparative Evaluation of Flexural Strength Among Cad-Cam Milled and Resin Provisional Restoration-an in vitro Study
    Karthikeyan, Gayathri
    Ashok, V
    Kumar, Kiran
    Ganapathy, Dhanraj
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (08): : 187 - 191
  • [42] Evaluation of Internal and Marginal Fit of Two Metal Ceramic System - In Vitro Study
    Harish, V
    Ali, Mohamed S. A.
    Jagadesan, N.
    Ifthikar, Mohamed
    Senthil, Siva
    Basak, Debasish
    Huda, Febel
    Priyanka
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (12) : ZC53 - ZC56
  • [43] Marginal Integrity of CAD/CAM Ceramic Crowns Using Two Different Finish Line Designs
    Akbar, Jaber Hussain
    Omar, Ridwaan
    Al-Tarakmah, Yacoub
    MEDICAL PRINCIPLES AND PRACTICE, 2021, 30 (05) : 443 - 447
  • [44] An In Vitro Comparison of the Marginal Adaptation Accuracy of CAD/CAM Restorations Using Different Impression Systems
    Shembesh, Marwa
    Ali, Ala
    Finkelman, Matthew
    Weber, Hans-Peter
    Zandparsa, Roya
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (07): : 581 - 586
  • [45] Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer
    Khaledi, Amir-Alireza
    Farzin, Mitra
    Akhlaghian, Marzieh
    Pardis, Soheil
    Mir, Negar
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01): : 81 - 86
  • [46] Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study
    Yilmaz, Burak
    Cakmak, Gulce
    Batak, Burcu
    Johnston, William M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (03) : 373 - 379
  • [47] Evaluation of the marginal integrity of ceramic copings with different marginal angles using two different CAD/CAM systems
    Giannetopoulos, Sotiris
    van Noort, Richard
    Tsitrou, Effrosyni
    JOURNAL OF DENTISTRY, 2010, 38 (12) : 980 - 986
  • [48] Evaluation of the marginal fit of CAD-CAM zirconia copings: Comparison of 2D and 3D measurement methods
    Boitelle, Philippe
    Tapie, Laurent
    Mawussi, Bernardin
    Fromentin, Olivier
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01): : 75 - 81
  • [49] Biomechanical behavior and Weibull survival of CAD-CAM endocrowns with different marginal designs: A 3D finite element analysis
    AboElhassan, Rewaa G.
    Watts, David C.
    Alamoush, Rasha A.
    Elraggal, Alaaeldin
    DENTAL MATERIALS, 2024, 40 (02) : 227 - 235
  • [50] Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems
    Lee, Kyu-Bok
    Park, Charn-Woon
    Kim, Kyo-Han
    Kwon, Tae-Yub
    DENTAL MATERIALS JOURNAL, 2008, 27 (03) : 422 - 426