Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study

被引:5
|
作者
Yilmaz, Burak [1 ,2 ,3 ]
Cakmak, Gulce [4 ]
Batak, Burcu [5 ]
Johnston, William M. [3 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Istanbul Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey
[5] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
abutment; internal conical connection; removal torque; screw; zirconia;
D O I
10.1111/cid.13001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants. Purpose To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading. Materials and methods Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (alpha = 0.05). Results Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants. Conclusions Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type.
引用
下载
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [1] Displacement comparison of CAD-CAM titanium and zirconia abutments to implants with different conical connections
    Yilmaz, Burak
    Hashemzadeh, Shervin
    Seidt, Jeremy D.
    Clelland, Nancy L.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) : 200 - 203
  • [2] In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants
    AL-Meraikhi, Hadi
    Yilmaz, Burak
    McGlumphy, Edwin
    Brantley, William
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 409 - 416
  • [3] Evaluation of the Fatigue Strength of a CAD-CAM Nanoceramic Resin Crown on Titanium and Zirconia-Titanium Abutments
    Graiff, Lorenzo
    Savio, Gianpaolo
    Di Fiore, Adolfo
    Rosso, Stefano
    Meneghello, Roberto
    Uccheddu, Francesca
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [4] Fatigue fracture resistance of titanium and chairside CAD-CAM zirconia implant abutments supporting zirconia crowns: An in vitro comparative and finite element analysis study
    Giner, Sergio
    Bartolome, Jose F.
    Gomez-Cogolludo, Pablo
    Castellote, Carlos
    Pradies, Guillermo
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 503.e1 - 503.e9
  • [5] Comparing the Fracture Resistance and Modes of Failure in Different Types of CAD/CAM Zirconia Abutments with Internal Hexagonal Implants: An In Vitro Study
    Chang, Yu-Tsen
    Wu, Yu-Ling
    Chen, Hung-Shyong
    Tsai, Ming-Hsu
    Chang, Chia-Chen
    Wu, Aaron Yu-Jen
    MATERIALS, 2022, 15 (07)
  • [6] Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study
    Molinero-Mourelle, Pedro
    Roccuzzo, Andrea
    Yilmaz, Burak
    Lam, Walter Yu Hang
    Pow, Edmond H. N.
    Highsmith, Jaime Del Rio
    Gomez-Polo, Miguel
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (09) : 945 - 952
  • [7] Layered Zirconia Crowns Bonded to CAD/CAM Titanium Abutments Using Angulated Screw Access: A Prospective Closed Cohort Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 37 - 45
  • [8] Comparison of the strain developed around implants with angled abutments with two reinforced polymeric CAD-CAM superstructure materials: An in vitro comparative study
    Omaish, Hadeer Hassan M.
    Abdelhamid, Ahmed M.
    Neena, Akram F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 634.e1 - 634.e8
  • [9] Evaluation of the fracture resistance and failure types of different CAD-CAM ceramic crowns supported by angled titanium abutments
    Yuksel, Merve
    Saygin, Aysegul Goze
    Bolayir, Giray
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (07): : 594 - 601
  • [10] Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants—an in vitro study
    Michael Stimmelmayr
    Anna Lang
    Florian Beuer
    Sonia Mansour
    Kurt Erdelt
    Gerald Krennmair
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 1801 - 1806