Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study

被引:5
|
作者
Yilmaz, Burak [1 ,2 ,3 ]
Cakmak, Gulce [4 ]
Batak, Burcu [5 ]
Johnston, William M. [3 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Istanbul Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey
[5] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
abutment; internal conical connection; removal torque; screw; zirconia;
D O I
10.1111/cid.13001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants. Purpose To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading. Materials and methods Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (alpha = 0.05). Results Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants. Conclusions Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type.
引用
下载
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [41] Bond Strength Stability of Different Dual-Curing Adhesive Cements towards CAD-CAM Resin Nanoceramic: An In Vitro Study
    Alberto, Vergano Edoardo
    Andrea, Baldi
    Allegra, Comba
    Edoardo, Italia
    Giorgio, Ferrero
    Rossella, Femiano
    Felice, Femiano
    Nicola, Scotti
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [42] Assessment of reliability of CAD-CAM tooth-colored implant custom abutments
    Guilherme, Nuno Marques
    Chung, Kwok-Hung
    Flinn, Brian D.
    Zheng, Cheng
    Raigrodski, Ariel J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (02): : 206 - 213
  • [43] Influence of Different CAD/CAM Crown Materials on the Fracture of Custom-Made Titanium and Zirconia Implant Abutments After Artificial Aging
    Elsayed, Adham
    Farrag, Gasser
    Chaar, Mohamed Sad
    Abdelnabi, Nouran
    Kern, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 91 - 96
  • [44] Customized CAD-CAM healing abutment for delayed loaded implants
    Alshhrani, Waled M.
    Al Amri, Mohammad D.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (02): : 176 - 179
  • [45] Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
    Daehne, Felix
    Meissner, Heike
    Boening, Klaus
    Arnold, Christin
    Gutwald, Ralf
    Prause, Elisabeth
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [46] CEMENTATION OF CAD-CAM PORCELAIN RESTORATIONS - AN IN-VITRO MICROLEAKAGE STUDY
    LOPRESTI, J
    DAVID, S
    CALAMIA, J
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 136 - 136
  • [47] Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
    Felix Dähne
    Heike Meißner
    Klaus Böning
    Christin Arnold
    Ralf Gutwald
    Elisabeth Prause
    International Journal of Implant Dentistry, 7
  • [48] CEMENTATION OF CAD-CAM PORCELAIN RESTORATIONS - AN IN-VITRO MICROLEAKAGE STUDY
    DAVID, S
    LOPRESTI, J
    CALAMIA, J
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 490 - 490
  • [50] Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems
    Bae, Eun-Bin
    Cho, Won-Tak
    Park, Do-Hyun
    Hwang, Su-Hyun
    Lee, So-Hyoun
    Yun, Mi-Jung
    Jeong, Chang-Mo
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (03): : 155 - 170