Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study

被引:5
|
作者
Yilmaz, Burak [1 ,2 ,3 ]
Cakmak, Gulce [4 ]
Batak, Burcu [5 ]
Johnston, William M. [3 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[2] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[3] Ohio State Univ, Coll Dent, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
[4] Istanbul Okan Univ, Dept Prosthodont, Fac Dent, Istanbul, Turkey
[5] Ankara Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
关键词
abutment; internal conical connection; removal torque; screw; zirconia;
D O I
10.1111/cid.13001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Limited information is available regarding the removal torque values (RTVs) of screws of different abutment materials when used with different implants. Purpose To evaluate the effect of implant type and abutment material (zirconia; Zir and titanium; Ti) on the RTVs of abutment screws after cyclic loading. Materials and methods Internal conical connection implants (CC, OsseoSpeed TX) and modified internal conical connection implants (MCC, OsseoSpeed EV) (n = 10) were clamped in resin dies. Zir and Ti (N = 20) custom abutments were tightened to implants (20 Ncm for CC and 25 Ncm for MCC) as specified by their manufacturers. The abutments were cyclically loaded by using a sequentially increased loading protocol; 2-million cycles under 100 N, 3-million cycles under 200 N, and 2-million cycles under 300 N loads with 2 Hz. After 7 million cycles, RTVs (Ncm) were measured by using a torque gauge. The data were analyzed with ANOVA by using the restricted maximum likelihood estimation method. Tukey-Kramer adjustment was used for any significant interaction of implant-abutment pairs (alpha = 0.05). Results Two CC implants, 1 with Ti and 1 with Zir abutment, fractured during cyclic loading (under 300 N loads within the 6th and 7th million cycles) and discarded for statistical analysis. Only implant type had a significant effect on RTVs (p <0.001). Screws of Ti abutments on MCC implants had significantly higher RTVs than the screws of Ti (p = 0.003) and Zir (p = 0.005) abutments on CC implants. Conclusions Implant type affected the RTVs, however, the RTVs were higher than the initial torque values for all groups. Screws of Ti abutments on implant, which required greater initial torque values had higher RTVs than the screws of Ti and Zir abutments on the implant that required smaller initial torque values. RTVs were similar for Zir and Ti abutment screws within each implant type.
引用
下载
收藏
页码:373 / 379
页数:7
相关论文
共 50 条
  • [21] Microgap Between Zirconia Abutments and Titanium Implants
    Baixe, Sebastien
    Fauxpoint, Gabriel
    Arntz, Youri
    Etienne, Olivier
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 455 - 460
  • [22] Microbiome of titanium and zirconia dental implants abutments
    do Nascimento, Cassio
    Pita, Murillo Sucena
    Santos, Emerson de Souza
    Monesi, Nadia
    Pedrazzi, Vinicius
    de Albuquerque Junior, Rubens Ferreira
    Ribeiro, Ricardo Faria
    DENTAL MATERIALS, 2016, 32 (01) : 93 - 101
  • [23] FRACTURE RESISTANCE OF TITANIUM AND ZIRCONIA ABUTMENTS: AN IN VITRO STUDY
    Foong, Jamie K. W.
    Judge, Roy B.
    Palamara, Joseph E.
    Swain, Michael V.
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (05): : 304 - 312
  • [24] Retentive strength of implant-supported CAD-CAM lithium disilicate crowns on zirconia custom abutments using 6 different cements
    Sellers, Krysta
    Powers, John M.
    Kiat-amnuay, Sudarat
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 247 - 252
  • [25] Wear of monolithic zirconia against different CAD-CAM and indirect restorative materials
    Ozkir, Serhat Emre
    Bicer, Mehmet
    Deste, Gonca
    Karakus, Elif
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 505 - 511
  • [26] The marginal fit of CAD-CAM zirconia cores with different proximal margin configurations
    Puntsag, O. E.
    Bae, E. K.
    Lee, J. H.
    Lee, K. W.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 1409 - +
  • [27] Comparative Analysis of Screw Loosening With Prefabricated Abutments and Customized CAD/CAM Abutments
    Paek, Janghyun
    Woo, Yi-Hyung
    Kim, Hyeong-Seob
    Pae, Ahran
    Noh, Kwantae
    Lee, Hyeonjong
    Kwon, Kung-Rock
    IMPLANT DENTISTRY, 2016, 25 (06) : 770 - 774
  • [28] The Milling Procedure Influences of a CAD-CAM Zirconia Framework
    Zhao, Yongqi
    Li, Wei
    Liao, Yunmao
    Jiang, Li
    Feng, Yu
    INEC: 2010 3RD INTERNATIONAL NANOELECTRONICS CONFERENCE, VOLS 1 AND 2, 2010, : 1429 - 1430
  • [29] A Comparative Evaluation of Vertical Marginal Gap for Vented and Precemented Cad-Cam Zirconium Copings on Angulated Abutments: An In vitro Study
    Passanha, Divya N.
    Sankeshwari, Banashree
    Pattanshetti, Channaveer
    Dhole, Rohit
    Miyyapuram, Sonica
    Zawar, Yash
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S934 - S936
  • [30] Fracture Resistance of Zirconia Abutments with or without a Titanium Base: An In Vitro Study for Tapered Conical Connection Implants
    Watanabe, Shota
    Nakano, Tamaki
    Ono, Shinji
    Yamanishi, Yasufumi
    Matsuoka, Takashi
    Ishigaki, Shoichi
    MATERIALS, 2022, 15 (01)