Comparative evaluation of marginal fit accuracy of two different designs of endocrown manufactured through CAD-CAM system: An in vitro study

被引:0
|
作者
Gupta, Khushbu Rakesh [1 ]
Gupta, Deepesh Kumar [1 ]
Jha, Anumeha [1 ]
Shukla, Shivam B. [1 ]
Dubey, Aayush Mukund [2 ]
机构
[1] Govt Dent Coll & Hosp, Dept Oral & Maxillofacial Prosthodont & Implantol, Raipur, Chhattisgarh, India
[2] Univ Cincinnati, Coll Med, Dept Epidemiol, Cincinnati, OH USA
来源
关键词
Endocrown; marginal fit; ferrule; CAD-CAM; intraoral scanner;
D O I
10.4103/jips.jips_207_24
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aims:To compare the accuracy of marginal fit of CAD-CAM endocrown with two different preparation forms, i.e., endocrown with ferrule and endocrown without ferrule.Settings and Design:Various studies have opined on the impact of preparation form on the marginal fit of endocrown, but studies on the effect on the marginal fit of digitally milled endocrown with and without ferrule are sparse.Materials and Methods:Total of 30 typodont were sectioned 3 mm above the cemento-enamel junction, and central cavity was prepared to depict a severely destructed tooth. The typodonts were divided into two groups: Group 1 contained specimens for endocrown without ferrule (WoF); Group 2 contained specimens for endocrown with ferrule (WF). The typodonts were prepared based on standard preparation. The specimens were then scanned using intraoral scanner, and the stereolithography (STL) was generated. Endocrowns were designed in the Exocad software using a digital library. The STL file format is translated into millable data file format (CNC- Computer numerical control) in the inLAB MC X5 Milling machine. The marginal fit of endocrowns was then assessed in the stereomicroscope.Statistical Analysis:The data was analysed with a digital image analyser. The result was generated using a two-way ANOVA test. The significance level was set at P <= 0.05.Results:In the present study, the marginal fit of WoF showed a superior marginal fit than WF. A statistically significant difference was seen in the marginal fit of two endocrowns, with a higher marginal discrepancy observed in the endocrown with the ferrule. The P value for the difference in the means of the marginal gap without and with ferrule (-13.42) is zero. Maximum marginal gap of 96 micron is observed for with ferrule (WF) design at location B. Minimum marginal gap of 29 micron is observed for without ferrule (WoF) at location D.Conclusions:Endocrown without a ferrule can provide a better marginal fit and can contribute to the long-term survival of restoration.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [21] Evaluation of Marginal and Internal Fit of CAD/CAM Endocrowns with Different Cavity Tapers
    Hajimahmoodi, Mohammedreza
    Raseipour, Sasan
    Mroue, Mohammad
    Ghodsi, Safoura
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (02) : 189 - 193
  • [22] Comparative Evaluation of Wear Resistance Among Cad-Cam and Resin Interim Restoration - an in Vitro Study
    Reddy, Meghana J.
    Ashok, V
    Kumar, Kiran
    Ganapathy, Dhanraj
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (08): : 224 - 228
  • [23] Biomechanical behavior of endocrown restorations with different CAD-CAM materials: A 3D finite element and in vitro analysis
    Zheng, Ziting
    He, Yunyan
    Ruan, Wenhao
    Ling, Zhiting
    Zheng, Chunqing
    Gai, Yawen
    Yan, Wenjuan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 890 - 899
  • [24] Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM
    Tsitrou, Effrosyni A.
    Northeast, Simon E.
    van Noort, Richard
    JOURNAL OF DENTISTRY, 2007, 35 (01) : 68 - 73
  • [25] Fit accuracy of removable partial denture mental frameworks produced by CAD-CAM - a clinical study
    Conceicao, Pedro R.
    Franco, Margarida
    Alves, Nuno
    Portugal, Jaime
    Neves, Cristina B.
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2021, 62 (04): : 194 - 200
  • [26] Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study
    Herschdorfer, Laura
    Negreiros, William Matthew
    Gallucci, German O.
    Hamilton, Adam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 905 - 910
  • [27] Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials
    Azarbal, Atousa
    Azarbal, Mohsen
    Engelmeier, Robert L.
    Kunkel, Thomas C.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (05): : 421 - 428
  • [28] Evaluation of marginal and internal fit of lithium disilicate CAD-CAM crowns with different finish lines by using a micro-CT technique
    Rizonaki, Maria
    Jacquet, Wolfgang
    Bottenberg, Peter
    Depla, Lennert
    Boone, Matthieu
    De Coster, Peter J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 890 - 898
  • [29] Evaluation of Marginal Gap/Fit of Zirconia Copings & Full Contoured Monolith Zirconia Crowns (CAD/CAM) - A Comparative In-Vitro Study
    Zacharias, Liya
    Shetty, Rajesh
    Zahid, Mohammad
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2021, 10 (20): : 1483 - 1488
  • [30] An in vitro study measuring marginal gaps of inlay restorations fabricated from different CAD-CAM materials after thermocycling
    Taha, Ahmed Ismail
    Hafez, Mona Elshirbini
    BMC ORAL HEALTH, 2023, 23 (01)