Collision Cross Section Measurements in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) Based on the Flipping-Filtering Method

被引:0
|
作者
Li, Dayu [1 ,2 ]
Wang, Zhiwei [1 ,2 ]
Fan, Yanying [1 ,2 ]
Xu, Wei [3 ]
机构
[1] Northeastern Univ, Sch Comp Sci & Engn, Shenyang, Peoples R China
[2] Northeastern Univ, Key Lab Intelligent Comp Med Image, Minist Educ, Shenyang, Peoples R China
[3] Beijing Inst Technol, Sch Med Technol, Beijing, Peoples R China
来源
JOURNAL OF MASS SPECTROMETRY | 2025年 / 60卷 / 05期
关键词
RESOLUTION; BIOMOLECULES;
D O I
10.1002/jms.5136
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ion collision cross section (CCS) is closely related to the structural and physical conformation of compounds, making it an ideal parameter for constructing databases. In recent years, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has gained widespread application in CCS measurements thanks to its ultra-high mass resolution and accuracy. Due to the collisions between ions and neutral molecules within the FT-ICR MS cell, the image current decays. Based on this feature, the ion CCS can be precisely calculated by applying corresponding collision models and algorithms. A new time-frequency analysis method is introduced: the flipping-filtering method based on the Levenberg-Marquardt algorithm. Before filtering, the data undergoes flipping and extension, effectively mitigating the issue of signal point waste commonly associated with traditional filtering techniques. This approach ensures a smooth and uninterrupted envelope of the image current signal while significantly enhancing the accuracy of decay factor and ion CCS measurements. Compared to the linewidth correction method and the line shape fitting method, this method exhibits superior noise resistance and resolution capabilities, serving as a valuable adjunct to ion CCS measurement techniques.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Sewage and Organic Pollution Compounds in Nairobi River Urban Sediments Characterized by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR-MS)
    Downham, Rory P.
    Vane, Christopher H.
    Gannon, Benedict
    Olaka, Lydia A.
    Barrow, Mark P.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2024, 35 (10) : 2376 - 2389
  • [42] Water-soluble organic compounds in ambient aerosol: A study using positive ion mode electrospray ionization Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry
    Saranjampour, Parichehr
    Samburova, Vera
    Hallar, A. Gannet
    Lowenthal, Douglas
    Zielinska, Barbara
    Mazzoleni, Lynn R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [43] Simultaneous determination of analyte concentrations, gas-phase basicities, and proton transfer kinetics using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS)
    Szulejko, Jan E.
    Luo, Zhaohui
    Solouki, Touradj
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 257 (1-3) : 16 - 26
  • [44] Molecular characterization of polar organic aerosol constituents in off-road engine emissions using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS): implications for source apportionment
    Cui, Min
    Li, Cheng
    Chen, Yingjun
    Zhang, Fan
    Li, Jun
    Jiang, Bin
    Mo, Yangzhi
    Li, Jia
    Yan, Caiqing
    Zheng, Mei
    Xie, Zhiyong
    Zhang, Gan
    Zheng, Junyu
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2019, 19 (22) : 13945 - 13956
  • [45] Stepwise Structural Characterization of Asphaltenes during Deep Hydroconversion Processes Determined by Atmospheric Pressure Photoionization (APPI) Fourier Transform Ion Cyclotron Resonance (FT-ICR) Mass Spectrometry
    Purcell, Jeremiah M.
    Merdrignac, Isabelle
    Rodgers, Ryan P.
    Marshall, Alan G.
    Gauthier, Thierry
    Guibard, Isabelle
    ENERGY & FUELS, 2010, 24 (04) : 2257 - 2265
  • [46] Collision Cross Section Measurements for Biomolecules within a High-Resolution Fourier Transform Ion Cyclotron Resonance Cell
    Mao, Lu
    Chen, Yu
    Xin, Yi
    Chen, Yu
    Zheng, Li
    Kaiser, Nathan K.
    Marshall, Alan G.
    Xu, Wei
    ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4072 - 4075
  • [47] Characterization of Tetrahymena histone H2B variants and posttranslational populations by electron capture dissociation (ECD) Fourier transform ion cyclotron mass spectrometry (FT-ICR MS)
    Medzihradszky, KF
    Zhang, X
    Chalkley, RJ
    Guan, S
    McFarland, MA
    Chalmers, MJ
    Marshall, AG
    Diaz, RL
    Allis, CD
    Burlingame, AL
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (09) : 872 - 886
  • [48] LASER-DESORPTION-IONIZATION FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE (LDI-FT-ICR) MASS-SPECTROMETRY (MS) OF BACTERIAL OLIGOSACCHARIDES
    LAM, Z
    BEYNON, L
    COMISAROW, MB
    DUTTON, GGS
    BJARNASON, A
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1991, 19 (04) : 922 - 929
  • [49] Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry
    Smith, RD
    Pasa-Tolic, L
    Lipton, MS
    Jensen, PK
    Anderson, GA
    Shen, YF
    Conrads, TP
    Udseth, HR
    Harkewicz, R
    Belov, ME
    Masselon, C
    Veenstra, TD
    ELECTROPHORESIS, 2001, 22 (09) : 1652 - 1668
  • [50] Comparative compositional analysis of untreated and hydrotreated oils by 15T ultrahigh resolution atmospheric pressure photo ionization Fourier transform ion cyclotron resonance mass spectrometry (APPI FT-ICR MS)
    Orrego-Ruiz, Jorge A.
    Gomez-Escudero, Andrea
    Mojica-Alarcon, Martin
    Murcia-Celis, Beatriz
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246