Simultaneous determination of analyte concentrations, gas-phase basicities, and proton transfer kinetics using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS)

被引:12
|
作者
Szulejko, Jan E. [1 ]
Luo, Zhaohui [1 ]
Solouki, Touradj [1 ]
机构
[1] Univ Maine, Dept Chem, Orono, ME 04469 USA
基金
美国国家科学基金会;
关键词
gas-phase basicity (GB); GC/FT-ICR MS; multiplexed reactant ion monitoring (MRIM); proton affinity (PA); thermokinetic;
D O I
10.1016/j.ijms.2006.05.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Details on using analyte gas-phase basicity (GB) or proton affinity (PA) as an additional analysis dimension in GC/FT-ICR MS are reported. Ion-molecule reactions of chemical ionization (CI) reagent ions with the GC separated C-1, C-2, and C-3 aromatic neutral (viz., toluene, m-xylene, and mesitylene) and ketone (acetone, 3-pentanone, and 4-heptanone) molecules were monitored. A suite of Cl reagent ions was generated by self-chemical ionization (SCI) of ethanol in an ICR cell. Multiplexed reactant ion monitoring (MRIM) of the CI reagent ions (RiH+) was used for GB bracketing of the neutral analytes eluting from the GC column. The PAs of the conjugate bases (R-i) of the reagent/reactant ions spanned a wide range (similar to 170 to similar to 200 kcal mol(-1)). A kinetic model was constructed to relate the degree of reactant ion depletion to analyte concentration and proton transfer reaction efficiency. Our experimental GB estimations, based on the thermokinetic data, were in broad agreement with the GB values reported in the NIST database and primary sources (experimental and ab initio). Experimentally measured MRIM chromatogram profiles and kinetic analysis were used to estimate analyte gas-phase pressures in the ICR cell and losses to the surfaces in the ICR vacuum chamber. The MRIM approach permits GB determinations of multiple analytes in a single GC run and provides an additional dimension to improve analytical resolution in GC/FT-ICR MS. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [1] Proton transfer reactions of halogenated compounds: Using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS) and ab initio calculations
    Silwal, Indira K. C.
    Rasaiah, Jayendran C.
    Szulejko, Jan E.
    Solouki, Touradj
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 293 (1-3) : 1 - 11
  • [3] A tandem mass spectrometry and Fourier transform ion cyclotron resonance (FT-ICR) study of RMn(+)(crown-ether) complexes in the gas phase
    Zagorevskii, DV
    Holmes, JL
    Watson, CH
    Eyler, JR
    EUROPEAN MASS SPECTROMETRY, 1997, 3 (01): : 27 - 36
  • [4] Identification of Dihydroxy Aromatic Compounds in a Low-Temperature Pyrolysis Coal Tar by Gas Chromatography-Mass Spectrometry (GC-MS) and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Shi, Quan
    Yan, Yan
    Wu, Xiaojiao
    Li, Shuyuan
    Chung, Keng H.
    Zhao, Suoqi
    Xu, Chunming
    ENERGY & FUELS, 2010, 24 (10) : 5533 - 5538
  • [5] Laser pyrolysis of cellulose using fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry.
    Leibold, K
    Hanson, CD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U359 - U359
  • [6] Metabolmics using Fourier transform ion cyclotron mass spectrometry - 1: Development of platform for FT-ICR MS analysis
    Kimura, A
    Oikawa, A
    Wadano, K
    Sakurai, N
    Suzuki, H
    Saito, K
    Shibata, D
    Kanaya, S
    Ohta, D
    PLANT AND CELL PHYSIOLOGY, 2005, 46 : S143 - S143
  • [7] Utilising Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) to track the oxidation of lignin by an alkaliphilic laccase
    Towle, Zak
    Cruickshank, Faye
    Mackay, C. Logan
    Clarke, David J.
    Horsfall, Louise E.
    ANALYST, 2024, 149 (08) : 2399 - 2411
  • [8] Study of gas-phase molecular recognition using Fourier transform ion cyclotron resonance mass spectrometry (FTICR/MS)
    Dearden, DV
    Liang, YJ
    Nicoll, JB
    Kellersberger, KA
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (09): : 989 - 997
  • [9] Volatile and semivolatile organic compound analysis using Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry
    Boisson, P
    Decouzon, M
    Gal, JF
    Maria, PC
    Pagliardini, A
    ANALUSIS, 1995, 23 (09) : 441 - 447