Simultaneous determination of analyte concentrations, gas-phase basicities, and proton transfer kinetics using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS)

被引:12
|
作者
Szulejko, Jan E. [1 ]
Luo, Zhaohui [1 ]
Solouki, Touradj [1 ]
机构
[1] Univ Maine, Dept Chem, Orono, ME 04469 USA
基金
美国国家科学基金会;
关键词
gas-phase basicity (GB); GC/FT-ICR MS; multiplexed reactant ion monitoring (MRIM); proton affinity (PA); thermokinetic;
D O I
10.1016/j.ijms.2006.05.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Details on using analyte gas-phase basicity (GB) or proton affinity (PA) as an additional analysis dimension in GC/FT-ICR MS are reported. Ion-molecule reactions of chemical ionization (CI) reagent ions with the GC separated C-1, C-2, and C-3 aromatic neutral (viz., toluene, m-xylene, and mesitylene) and ketone (acetone, 3-pentanone, and 4-heptanone) molecules were monitored. A suite of Cl reagent ions was generated by self-chemical ionization (SCI) of ethanol in an ICR cell. Multiplexed reactant ion monitoring (MRIM) of the CI reagent ions (RiH+) was used for GB bracketing of the neutral analytes eluting from the GC column. The PAs of the conjugate bases (R-i) of the reagent/reactant ions spanned a wide range (similar to 170 to similar to 200 kcal mol(-1)). A kinetic model was constructed to relate the degree of reactant ion depletion to analyte concentration and proton transfer reaction efficiency. Our experimental GB estimations, based on the thermokinetic data, were in broad agreement with the GB values reported in the NIST database and primary sources (experimental and ab initio). Experimentally measured MRIM chromatogram profiles and kinetic analysis were used to estimate analyte gas-phase pressures in the ICR cell and losses to the surfaces in the ICR vacuum chamber. The MRIM approach permits GB determinations of multiple analytes in a single GC run and provides an additional dimension to improve analytical resolution in GC/FT-ICR MS. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [21] Applications of Fourier Transform Ion Cyclotron Resonance (FT-ICR) and Orbitrap Based High Resolution Mass Spectrometry in Metabolomics and Lipidomics
    Ghaste, Manoj
    Mistrik, Robert
    Shulaev, Vladimir
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (06)
  • [22] Effect of endogenous microbiota on the molecular composition of cloud water: a study by Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS)
    Bianco, Angelica
    Deguillaume, Laurent
    Chaumerliac, Nadine
    Vaitilingom, Mickael
    Wang, Miao
    Delort, Anne-Marie
    Bridoux, Maxime C.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [23] Collision Cross Section Measurements in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) Based on the Flipping-Filtering Method
    Li, Dayu
    Wang, Zhiwei
    Fan, Yanying
    Xu, Wei
    JOURNAL OF MASS SPECTROMETRY, 2025, 60 (05):
  • [24] Effect of endogenous microbiota on the molecular composition of cloud water: a study by Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS)
    Angelica Bianco
    Laurent Deguillaume
    Nadine Chaumerliac
    Mickaël Vaïtilingom
    Miao Wang
    Anne-Marie Delort
    Maxime C. Bridoux
    Scientific Reports, 9
  • [25] SEGMENTED FOURIER-TRANSFORM AND ITS APPLICATION TO FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE (FT-ICR) MASS-SPECTROMETRY - ION ABUNDANCES AND MASS MEASUREMENTS
    DEKONING, LJ
    KORT, CWF
    PINKSE, FA
    NIBBERING, NMM
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 95 (01): : 71 - 92
  • [26] Dioxin Analysis by Gas Chromatography-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (GC-FTICRMS)
    Taguchi, Vince Y.
    Nieckarz, Robert J.
    Clement, Ray E.
    Krolik, Stefan
    Williams, Robert
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (11) : 1918 - 1921
  • [27] Platination of superoxide dismutase with cisplatin: tracking the ammonia ligands using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) (pg 1719, 2007)
    Weidt, Stefan K.
    Mackay, C. Logan
    Langridge-Smith, Pat R. R.
    Sadler, Peter J.
    CHEMICAL COMMUNICATIONS, 2007, (24) : 2542 - 2542
  • [28] Exploring Compositional Changes along In Situ Combustion and Their Implications on Emulsion Stabilization via Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Rojas-Ruiz, Fernando A.
    Bottia-Ramirez, Hernando
    Rodriguez-Rodriguez, Lilia
    Orrego-Ruiz, Jorge A.
    ENERGY & FUELS, 2017, 31 (11) : 11995 - 12003
  • [29] Data processing for fennel protein characterization by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS)
    Melfi, Maria Teresa
    Kanawati, Basem
    Schmitt-Kopplin, Philippe
    Macchia, Luigi
    Centonze, Diego
    Nardiello, Donatella
    DATA IN BRIEF, 2021, 35
  • [30] Increasing Polyaromatic Hydrocarbon (PAH) Molecular Coverage during Fossil Oil Analysis by Combining Gas Chromatography and Atmospheric-Pressure Laser Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Benigni, Paolo
    DeBord, J. Daniel
    Thompson, Christopher J.
    Gardinali, Piero
    Fernandez-Lima, Francisco
    ENERGY & FUELS, 2016, 30 (01) : 196 - 203