Simultaneous determination of analyte concentrations, gas-phase basicities, and proton transfer kinetics using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS)

被引:12
|
作者
Szulejko, Jan E. [1 ]
Luo, Zhaohui [1 ]
Solouki, Touradj [1 ]
机构
[1] Univ Maine, Dept Chem, Orono, ME 04469 USA
基金
美国国家科学基金会;
关键词
gas-phase basicity (GB); GC/FT-ICR MS; multiplexed reactant ion monitoring (MRIM); proton affinity (PA); thermokinetic;
D O I
10.1016/j.ijms.2006.05.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Details on using analyte gas-phase basicity (GB) or proton affinity (PA) as an additional analysis dimension in GC/FT-ICR MS are reported. Ion-molecule reactions of chemical ionization (CI) reagent ions with the GC separated C-1, C-2, and C-3 aromatic neutral (viz., toluene, m-xylene, and mesitylene) and ketone (acetone, 3-pentanone, and 4-heptanone) molecules were monitored. A suite of Cl reagent ions was generated by self-chemical ionization (SCI) of ethanol in an ICR cell. Multiplexed reactant ion monitoring (MRIM) of the CI reagent ions (RiH+) was used for GB bracketing of the neutral analytes eluting from the GC column. The PAs of the conjugate bases (R-i) of the reagent/reactant ions spanned a wide range (similar to 170 to similar to 200 kcal mol(-1)). A kinetic model was constructed to relate the degree of reactant ion depletion to analyte concentration and proton transfer reaction efficiency. Our experimental GB estimations, based on the thermokinetic data, were in broad agreement with the GB values reported in the NIST database and primary sources (experimental and ab initio). Experimentally measured MRIM chromatogram profiles and kinetic analysis were used to estimate analyte gas-phase pressures in the ICR cell and losses to the surfaces in the ICR vacuum chamber. The MRIM approach permits GB determinations of multiple analytes in a single GC run and provides an additional dimension to improve analytical resolution in GC/FT-ICR MS. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [31] Publisher Correction: Effect of endogenous microbiota on the molecular composition of cloud water: a study by Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS)
    Angelica Bianco
    Laurent Deguillaume
    Nadine Chaumerliac
    Mickaël Vaïtilingom
    Miao Wang
    Anne-Marie Delort
    Maxime C. Bridoux
    Scientific Reports, 9
  • [32] Characterization of Naphthenic Acids by Gas Chromatography-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Ortiz, Xavier
    Jobst, Karl J.
    Reiner, Eric J.
    Backus, Sean M.
    Peru, Kerry M.
    McMartin, Dena W.
    O'Sullivan, Gwen
    Taguchi, Vince Y.
    Headley, John V.
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7666 - 7673
  • [33] Molecular-level insights into environmental organic contaminants by high resolution fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry
    Rodgers, Ryan
    Rowland, Steven
    Chen, Huan
    McKenna, Amy
    Zito, Phoebe
    Corilo, Yuri E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [34] Characterization and Comparison of Nitrogen Compounds in Hydrotreated and Untreated Shale Oil by Electrospray Ionization (ESI) Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Chen, Xiaobo
    Shen, Benxian
    Sun, Jinpeng
    Wang, Chengxiu
    Shan, Honghong
    Yang, Chaohe
    Li, Chunyi
    ENERGY & FUELS, 2012, 26 (03) : 1707 - 1714
  • [35] Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses
    Thompson, Allison M.
    Stratton, Kelly G.
    Bramer, Lisa M.
    Zavoshy, Nicole S.
    McCue, Lee Ann
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (09)
  • [36] GAS-PHASE BASICITIES OF CUBANE, DODECAHEDRANE, AND METHYLDODECAHEDRANE AND 1,16-DIMETHYLDODECAHEDRANE AS MEASURED BY FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    SANTOS, I
    BALOGH, DW
    DOECKE, CW
    MARSHALL, AG
    PAQUETTE, LA
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1986, 108 (26) : 8183 - 8185
  • [37] Identification of Delta(9)-Tetrahydrocannabinol (Delta(9)-THC) in Cannabis Seeds by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (ESI(-)FT-ICR MS)
    dos Santos, Nayara A.
    Ortiz, Rafael S.
    Limberger, Renata P.
    Lacerda Junior, Valdemar
    Romao, Wanderson
    ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, 2018, 10 (05): : 381 - 385
  • [38] High-field Fourier transform ion cyclotron resonance mass spectrometry for simultaneous trapping and gas-phase hydrogen/deuterium exchange of peptide ions
    Freitas, MA
    Hendrickson, CL
    Emmett, MR
    Marshall, AG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (10) : 1012 - 1019
  • [40] Gas-phase oxidation reactions of neptunium and plutonium ions investigated via Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
    Santos, M
    Marçalo, J
    de Matos, AP
    Gibson, JK
    Haire, RG
    JOURNAL OF PHYSICAL CHEMISTRY A, 2002, 106 (31): : 7190 - 7194