Collision Cross Section Measurements in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS) Based on the Flipping-Filtering Method

被引:0
|
作者
Li, Dayu [1 ,2 ]
Wang, Zhiwei [1 ,2 ]
Fan, Yanying [1 ,2 ]
Xu, Wei [3 ]
机构
[1] Northeastern Univ, Sch Comp Sci & Engn, Shenyang, Peoples R China
[2] Northeastern Univ, Key Lab Intelligent Comp Med Image, Minist Educ, Shenyang, Peoples R China
[3] Beijing Inst Technol, Sch Med Technol, Beijing, Peoples R China
来源
JOURNAL OF MASS SPECTROMETRY | 2025年 / 60卷 / 05期
关键词
RESOLUTION; BIOMOLECULES;
D O I
10.1002/jms.5136
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The ion collision cross section (CCS) is closely related to the structural and physical conformation of compounds, making it an ideal parameter for constructing databases. In recent years, Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) has gained widespread application in CCS measurements thanks to its ultra-high mass resolution and accuracy. Due to the collisions between ions and neutral molecules within the FT-ICR MS cell, the image current decays. Based on this feature, the ion CCS can be precisely calculated by applying corresponding collision models and algorithms. A new time-frequency analysis method is introduced: the flipping-filtering method based on the Levenberg-Marquardt algorithm. Before filtering, the data undergoes flipping and extension, effectively mitigating the issue of signal point waste commonly associated with traditional filtering techniques. This approach ensures a smooth and uninterrupted envelope of the image current signal while significantly enhancing the accuracy of decay factor and ion CCS measurements. Compared to the linewidth correction method and the line shape fitting method, this method exhibits superior noise resistance and resolution capabilities, serving as a valuable adjunct to ion CCS measurement techniques.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Publisher Correction: Effect of endogenous microbiota on the molecular composition of cloud water: a study by Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS)
    Angelica Bianco
    Laurent Deguillaume
    Nadine Chaumerliac
    Mickaël Vaïtilingom
    Miao Wang
    Anne-Marie Delort
    Maxime C. Bridoux
    Scientific Reports, 9
  • [22] Molecular-level insights into environmental organic contaminants by high resolution fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry
    Rodgers, Ryan
    Rowland, Steven
    Chen, Huan
    McKenna, Amy
    Zito, Phoebe
    Corilo, Yuri E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [23] Characterization and Comparison of Nitrogen Compounds in Hydrotreated and Untreated Shale Oil by Electrospray Ionization (ESI) Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS)
    Chen, Xiaobo
    Shen, Benxian
    Sun, Jinpeng
    Wang, Chengxiu
    Shan, Honghong
    Yang, Chaohe
    Li, Chunyi
    ENERGY & FUELS, 2012, 26 (03) : 1707 - 1714
  • [24] A tandem mass spectrometry and Fourier transform ion cyclotron resonance (FT-ICR) study of RMn(+)(crown-ether) complexes in the gas phase
    Zagorevskii, DV
    Holmes, JL
    Watson, CH
    Eyler, JR
    EUROPEAN MASS SPECTROMETRY, 1997, 3 (01): : 27 - 36
  • [25] Platination of superoxide dismutase with cisplatin: tracking the ammonia ligands using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) (pg 1719, 2007)
    Weidt, Stefan K.
    Mackay, C. Logan
    Langridge-Smith, Pat R. R.
    Sadler, Peter J.
    CHEMICAL COMMUNICATIONS, 2007, (24) : 2542 - 2542
  • [26] Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) peak intensity normalization for complex mixture analyses
    Thompson, Allison M.
    Stratton, Kelly G.
    Bramer, Lisa M.
    Zavoshy, Nicole S.
    McCue, Lee Ann
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (09)
  • [27] Method and Applications of Ion Collision Cross Section Measurement Based on Fourier Transform-Ion Cyclotron Resonance
    Zhang K.-L.
    Xu S.-Y.
    Jiao L.-Y.
    Du M.-Y.
    Yan H.
    Mao G.-G.
    Li S.-Q.
    Kong X.-L.
    Journal of Chinese Mass Spectrometry Society, 2022, 43 (05) : 623 - 634
  • [28] Collision cross section (CCS) measurement by ion cyclotron resonance mass spectrometry with short-time Fourier transform
    Hu, Miao
    Zhang, Linzhou
    He, Shan
    Xu, Chunming
    Shi, Quan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (09) : 751 - 761
  • [29] Proton transfer reactions of halogenated compounds: Using gas chromatography/Fourier transform ion cyclotron resonance mass spectrometry (GC/FT-ICR MS) and ab initio calculations
    Silwal, Indira K. C.
    Rasaiah, Jayendran C.
    Szulejko, Jan E.
    Solouki, Touradj
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 293 (1-3) : 1 - 11
  • [30] Identification of Delta(9)-Tetrahydrocannabinol (Delta(9)-THC) in Cannabis Seeds by Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (ESI(-)FT-ICR MS)
    dos Santos, Nayara A.
    Ortiz, Rafael S.
    Limberger, Renata P.
    Lacerda Junior, Valdemar
    Romao, Wanderson
    ORBITAL-THE ELECTRONIC JOURNAL OF CHEMISTRY, 2018, 10 (05): : 381 - 385