Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

被引:0
|
作者
Alabau-Dasi, Raquel [1 ]
Dominguez-Maldonado, Gabriel [2 ,3 ]
Ortega-Avila, Ana Belen [1 ,4 ]
Gordillo-Fernandez, Luis M. [3 ]
Ortiz-Romero, Mercedes [3 ]
Melchor-Rodriguez, Juan Manuel [5 ,6 ]
Gijon-Nogueron, Gabriel [1 ,4 ]
机构
[1] Univ Malaga, Fac Ciencias Salud, Dept Enfermeria & Podol, Malaga 29071, Spain
[2] Univ Malaga, Fac Ciencias Salud, Programa Doctorado, Malaga 29071, Spain
[3] Univ Seville, Dept Podol, Seville 41092, Spain
[4] Inst Invest Biomed Malaga & Plataforma Nanomed IBI, Malaga 29590, Spain
[5] Univ Granada, Fac Med, Dept Stat & Operat Res, Biostat Teaching Unit, Granada 18016, Spain
[6] Biomed Res Inst ibs GRANADA, Granada 18012, Spain
关键词
Achilles; reliability; tendon; ultrasonography; validation; SONOGRAPHIC EVALUATION; ULTRASOUND; DOMINANCE; EXERCISE;
D O I
10.3390/diagnostics14192221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. Method: Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon's thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. Results: The measurements at 6 cm from the calcaneal insertion showed alpha = 0.996, alpha = 0.998 for measurements at 4 cm using manual acquisition, and alpha = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (alpha = 0.999 and alpha = 1.000). Conclusions: The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon's thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound's applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon's thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] The interrater reliability of ultrasonography for Achilles tendon structure
    Paantjens, Marc
    Leeuw, Marco
    Helmhout, Pieter
    Isaac, Amanda
    De Maeseneer, Michel
    JOURNAL OF ULTRASONOGRAPHY, 2020, 20 (80) : E6 - E11
  • [2] Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies
    Filippucci, E.
    Aydin, S. Zehra
    Karadag, O.
    Salaffi, F.
    Gutierrez, M.
    Direskeneli, H.
    Grassi, W.
    ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (12) : 1850 - 1855
  • [3] Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies
    Aydin, S.
    Filippucci, E.
    Karadag, O.
    Salaffi, F.
    Gutierrez, M.
    Direskeneli, H.
    Grassi, W.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2008, 26 (04) : 734 - 734
  • [4] Ultrasonography of the Achilles tendon
    Grechenig, W
    Clement, H
    Bratschitsch, G
    Fankhauser, F
    Peicha, G
    ORTHOPADE, 2002, 31 (03): : 319 - 325
  • [5] Reliability and Accuracy of a Time-Efficient Method for the Assessment of Achilles Tendon Mechanical Properties by Ultrasonography
    Hunter, Steve
    Werth, Julian
    James, Darren
    Lambrianides, Yiannis
    Smith, Kenton
    Karamanidis, Kiros
    Epro, Gaspar
    SENSORS, 2022, 22 (07)
  • [6] Reliability and validation of the German Achilles tendon Total Rupture Score
    Arbab, Dorothe
    Lichte, Philip
    Gutteck, Natalia
    Bouillon, Bertil
    Arbab, Dariusch
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (02) : 454 - 460
  • [7] Reliability and validation of the Dutch Achilles tendon Total Rupture Score
    K. T. M. Opdam
    R. Zwiers
    J. I. Wiegerinck
    A. E. B. Kleipool
    R. Haverlag
    J. C. Goslings
    C. N. van Dijk
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 862 - 868
  • [8] Reliability and validation of the Dutch Achilles tendon Total Rupture Score
    Opdam, K. T. M.
    Zwiers, R.
    Wiegerinck, J. I.
    Kleipool, A. E. B.
    Haverlag, R.
    Goslings, J. C.
    van Dijk, C. N.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (03) : 862 - 868
  • [9] The value of ultrasonography of the Achilles tendon in traumatology
    Grechenig, W
    Clement, HG
    Fellinger, M
    Seggl, W
    RADIOLOGE, 1997, 37 (04): : 322 - 329
  • [10] The value of ultrasonography of the Achilles tendon in traumatology
    W. Grechenig
    H.-G. Clement
    M. Fellinger
    W. Seggl
    Der Radiologe, 1997, 37 : 322 - 329