Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

被引:0
|
作者
Alabau-Dasi, Raquel [1 ]
Dominguez-Maldonado, Gabriel [2 ,3 ]
Ortega-Avila, Ana Belen [1 ,4 ]
Gordillo-Fernandez, Luis M. [3 ]
Ortiz-Romero, Mercedes [3 ]
Melchor-Rodriguez, Juan Manuel [5 ,6 ]
Gijon-Nogueron, Gabriel [1 ,4 ]
机构
[1] Univ Malaga, Fac Ciencias Salud, Dept Enfermeria & Podol, Malaga 29071, Spain
[2] Univ Malaga, Fac Ciencias Salud, Programa Doctorado, Malaga 29071, Spain
[3] Univ Seville, Dept Podol, Seville 41092, Spain
[4] Inst Invest Biomed Malaga & Plataforma Nanomed IBI, Malaga 29590, Spain
[5] Univ Granada, Fac Med, Dept Stat & Operat Res, Biostat Teaching Unit, Granada 18016, Spain
[6] Biomed Res Inst ibs GRANADA, Granada 18012, Spain
关键词
Achilles; reliability; tendon; ultrasonography; validation; SONOGRAPHIC EVALUATION; ULTRASOUND; DOMINANCE; EXERCISE;
D O I
10.3390/diagnostics14192221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. Method: Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon's thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. Results: The measurements at 6 cm from the calcaneal insertion showed alpha = 0.996, alpha = 0.998 for measurements at 4 cm using manual acquisition, and alpha = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (alpha = 0.999 and alpha = 1.000). Conclusions: The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon's thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound's applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon's thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Reliability of a measurement technique for achilles tendon length
    Skypala, Jiri
    Jandacka, Daniel
    Hamill, Joseph
    JOURNAL OF SPORTS SCIENCES, 2019, 37 (20) : 2389 - 2395
  • [32] MRI Assessment of Degeneration of the Tendon in Achilles Tendon Ruptures
    Backer, Henrik C.
    Wong, Tony T.
    Vosseller, J. Turner
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (08) : 895 - 899
  • [33] Ultrasonography-guided Intervention in the Achilles Tendon and Plantar Fascia
    Martin, Silvia
    Morinigo, Javier Gomez
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2023, 27 (03) : 351 - 366
  • [34] Lesions of the Achilles tendon: Evaluation with ultrasonography and magnetic resonance imaging
    Ibrahim, Noha Mohamed AbdelMaboud
    Elsaeed, Hytham Haroun
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (03): : 581 - 587
  • [35] Musculoskeletal ultrasonography of the Achilles tendon and plantar fascia in spondyloarthritis patients
    Baccouche, Khadija
    Mani, Linda
    Elamri, Nejla
    Fathallah, Neila
    Zaghouani, Hounaida
    Belghali, Safaa
    Zeglaoui, Hela
    Bouajina, Elyes
    EGYPTIAN RHEUMATOLOGIST, 2018, 40 (04): : 249 - 253
  • [36] Measurement of Achilles tendon loading using shear wave tensiometry: A reliability study
    Schneebeli, Alessandro
    Falla, Deborah
    Cescon, Corrado
    Barbero, Marco
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2022, 62
  • [37] Myotonometry for the evaluation of Achilles tendon mechanical properties: a reliability and construct validity study
    Schneebeli, Alessandro
    Falla, Deborah
    Clijsen, Ron
    Barbero, Marco
    BMJ OPEN SPORT & EXERCISE MEDICINE, 2020, 6 (01):
  • [38] Reliability of the Copenhagen Achilles length measure (CALM) on patients with an Achilles tendon rupture
    Hansen, Maria Swennergren
    Kristensen, Morten Tange
    Budolfsen, Thomas
    Ellegaard, Karen
    Holmich, Per
    Barfod, Kristoffer Weisskirchner
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (01) : 281 - 290
  • [39] Reliability of the Copenhagen Achilles length measure (CALM) on patients with an Achilles tendon rupture
    Maria Swennergren Hansen
    Morten Tange Kristensen
    Thomas Budolfsen
    Karen Ellegaard
    Per Hölmich
    Kristoffer Weisskirchner Barfod
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 281 - 290
  • [40] A study of Achilles tendon rupture
    Mukherjee, S
    Rogers, S
    Mayeux, R
    Mukherjee, DP
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 381 - 383