Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

被引:0
|
作者
Alabau-Dasi, Raquel [1 ]
Dominguez-Maldonado, Gabriel [2 ,3 ]
Ortega-Avila, Ana Belen [1 ,4 ]
Gordillo-Fernandez, Luis M. [3 ]
Ortiz-Romero, Mercedes [3 ]
Melchor-Rodriguez, Juan Manuel [5 ,6 ]
Gijon-Nogueron, Gabriel [1 ,4 ]
机构
[1] Univ Malaga, Fac Ciencias Salud, Dept Enfermeria & Podol, Malaga 29071, Spain
[2] Univ Malaga, Fac Ciencias Salud, Programa Doctorado, Malaga 29071, Spain
[3] Univ Seville, Dept Podol, Seville 41092, Spain
[4] Inst Invest Biomed Malaga & Plataforma Nanomed IBI, Malaga 29590, Spain
[5] Univ Granada, Fac Med, Dept Stat & Operat Res, Biostat Teaching Unit, Granada 18016, Spain
[6] Biomed Res Inst ibs GRANADA, Granada 18012, Spain
关键词
Achilles; reliability; tendon; ultrasonography; validation; SONOGRAPHIC EVALUATION; ULTRASOUND; DOMINANCE; EXERCISE;
D O I
10.3390/diagnostics14192221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. Method: Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon's thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. Results: The measurements at 6 cm from the calcaneal insertion showed alpha = 0.996, alpha = 0.998 for measurements at 4 cm using manual acquisition, and alpha = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (alpha = 0.999 and alpha = 1.000). Conclusions: The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon's thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound's applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon's thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ultrasonography in evaluation of Achilles and patella tendon thickness
    Fredberg, U.
    Bolvig, L.
    Andersen, N. T.
    Stengaard-Pedersen, K.
    ULTRASCHALL IN DER MEDIZIN, 2008, 29 (01): : 60 - 65
  • [22] Achilles Tendon Ultrasonography for Diagnosis of Familial Hypercholesterolemia
    Junyent, M.
    Ros, E.
    CLINICA E INVESTIGACION EN ARTERIOSCLEROSIS, 2006, 18 (02): : 69 - 69
  • [23] Development and reliability of the Achilles Tendon Length Measure and comparison with the Achilles Tendon Resting Angle on patients with an Achilles tendon rupture
    Hansen, Maria Swennergren
    Barfod, Kristoffer Weisskirchner
    Kristensen, Morten Tange
    FOOT AND ANKLE SURGERY, 2017, 23 (04) : 275 - 280
  • [24] QUANTIFICATION OF MECHANICAL PROPERTIES IN HEALTHY ACHILLES TENDON USING CONTINUOUS SHEAR WAVE ELASTOGRAPHY: A RELIABILITY AND VALIDATION STUDY
    Corrigan, Patrick
    Zellers, Jennifer A.
    Balascio, Phoebe
    Silbernagel, Karin Gravare
    Cortes, Daniel H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (07): : 1574 - 1585
  • [25] Intraoperative Ultrasonography During Percutaneous Achilles Tendon Repair
    Soubeyrand, Marc
    Serra-Tosio, Geraldine
    Campagna, Raphael
    Molina, Veronique
    Sitbon, Philippe
    Biau, David J.
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (12) : 1069 - 1074
  • [26] The use of Achilles tendon ultrasonography for the diagnosis of familial hypercholesterolemia
    Descamps, OS
    Leysen, X
    Van Leuven, F
    Heller, FR
    ATHEROSCLEROSIS, 2001, 157 (02) : 514 - 518
  • [27] Achilles tendon pain and related pathologies: Diagnosis by ultrasonography
    Blankstein, A
    Cohen, I
    Diamant, L
    Heim, M
    Dudkiewicz, I
    Israeli, A
    Ganel, A
    Chechick, A
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2001, 3 (08): : 575 - 578
  • [28] Value of ultrasonography as a diagnostic tool of the Achilles tendon.
    Mahlfeld, K
    Kayser, R
    Mahlfeld, A
    Grasshoff, H
    Franke, J
    ULTRASCHALL IN DER MEDIZIN, 2001, 22 (02): : 87 - 90
  • [29] New Method for Measuring the Achilles Tendon Length by Ultrasonography
    Fukutani, Atsuki
    CURRENT MEDICAL IMAGING REVIEWS, 2014, 10 (04) : 259 - 265
  • [30] The reliability, reproducibility and utilization of the radiographic Achilles Tendon Loading Angle in the management of Achilles Tendon rupture
    Carmont, Michael R.
    Brorsson, Annelie
    Barfod, Kristoffer Weisskirchner
    Ginder, Laurence
    Littlehales, Julie
    Karlsson, Jon
    Nilsson-Helander, Katarina
    FOOT AND ANKLE SURGERY, 2021, 27 (07) : 760 - 766