Reliability and Accuracy of a Time-Efficient Method for the Assessment of Achilles Tendon Mechanical Properties by Ultrasonography

被引:0
|
作者
Hunter, Steve [1 ]
Werth, Julian [1 ]
James, Darren [1 ]
Lambrianides, Yiannis [1 ]
Smith, Kenton [1 ]
Karamanidis, Kiros [1 ]
Epro, Gaspar [1 ]
机构
[1] London South Bank Univ, Sport & Exercise Sci Res Ctr, Sch Appl Sci, London SE1 0AA, England
关键词
tendon elongation; tendon strain; tendon stiffness; muscle strength; MORPHOLOGICAL PROPERTIES; GASTROCNEMIUS MEDIALIS; APONEUROSIS; EXCURSION; UNIT; ALGORITHM; STRAIN;
D O I
10.3390/s22072549
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The assessment of the force-length relationship under mechanical loading is widely used to evaluate the mechanical properties of tendons and to gain information about their adaptation, function, and injury. This study aimed to provide a time-efficient ultrasound method for assessing Achilles tendon mechanical properties. On two days, eleven healthy young non-active adults performed eight maximal voluntary isometric ankle plantarflexion contractions on a dynamometer with simultaneous ultrasonographic recording. Maximal tendon elongation was assessed by digitizing ultrasound images at rest and at maximal tendon force. Achilles tendon stiffness index was calculated from the ratio of tendon force-to-strain. No within- and between-day differences were detected between the proposed method and manual frame by frame tracking in Achilles tendon maximal force, maximal elongation, maximal strain, and stiffness index. The overall coefficient of variation between trials ranged from 3.4% to 10.3% and average difference in tendon tracking between methods was less than 0.6% strain. Furthermore, an additional assessment demonstrated significant differences between elite athletes, healthy young, and older adults in Achilles tendon force and stiffness index. Hence, the analysis has the potential to reliably and accurately monitor changes in Achilles tendon mechanical properties due to aging and altered mechanical loading in a time-efficient manner.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Are the mechanical properties of Achilles tendon altered in CrossFit athletes? Reliability and accuracy of myotonometry
    Zajkowski, Sebastians
    Pasek, Jaroslaw
    Dwornik, Michal
    Zajaczkowski, Mateusz
    Cieslar, Grzegorz
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2023, 25 (02) : 103 - 113
  • [2] Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study
    Alabau-Dasi, Raquel
    Dominguez-Maldonado, Gabriel
    Ortega-Avila, Ana Belen
    Gordillo-Fernandez, Luis M.
    Ortiz-Romero, Mercedes
    Melchor-Rodriguez, Juan Manuel
    Gijon-Nogueron, Gabriel
    DIAGNOSTICS, 2024, 14 (19)
  • [3] The interrater reliability of ultrasonography for Achilles tendon structure
    Paantjens, Marc
    Leeuw, Marco
    Helmhout, Pieter
    Isaac, Amanda
    De Maeseneer, Michel
    JOURNAL OF ULTRASONOGRAPHY, 2020, 20 (80) : E6 - E11
  • [4] Reliability Of Variables Defining Mechanical And Material Properties Of The Achilles Tendon
    Intziegianni, Konstantina
    Cassel, Michael
    Koenig, Niklas
    Mayer, Frank
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 238 - 239
  • [5] Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies
    Filippucci, E.
    Aydin, S. Zehra
    Karadag, O.
    Salaffi, F.
    Gutierrez, M.
    Direskeneli, H.
    Grassi, W.
    ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (12) : 1850 - 1855
  • [6] Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies
    Aydin, S.
    Filippucci, E.
    Karadag, O.
    Salaffi, F.
    Gutierrez, M.
    Direskeneli, H.
    Grassi, W.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2008, 26 (04) : 734 - 734
  • [7] MEASURING ACHILLES TENDON MECHANICAL PROPERTIES: A RELIABLE, NONINVASIVE METHOD
    Joseph, Michael F.
    Lillie, Kurtis R.
    Bergeron, Daniel J.
    Denegar, Craig R.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2012, 26 (08) : 2017 - 2020
  • [8] New Method for Measuring the Achilles Tendon Length by Ultrasonography
    Fukutani, Atsuki
    CURRENT MEDICAL IMAGING REVIEWS, 2014, 10 (04) : 259 - 265
  • [9] Mechanical properties of the human Achilles tendon
    Wren, TAL
    Yerby, SA
    Beaupré, GS
    Carter, DR
    CLINICAL BIOMECHANICS, 2001, 16 (03) : 245 - 251
  • [10] Myotonometry for the evaluation of Achilles tendon mechanical properties: a reliability and construct validity study
    Schneebeli, Alessandro
    Falla, Deborah
    Clijsen, Ron
    Barbero, Marco
    BMJ OPEN SPORT & EXERCISE MEDICINE, 2020, 6 (01):