Reliability and Accuracy of a Time-Efficient Method for the Assessment of Achilles Tendon Mechanical Properties by Ultrasonography

被引:0
|
作者
Hunter, Steve [1 ]
Werth, Julian [1 ]
James, Darren [1 ]
Lambrianides, Yiannis [1 ]
Smith, Kenton [1 ]
Karamanidis, Kiros [1 ]
Epro, Gaspar [1 ]
机构
[1] London South Bank Univ, Sport & Exercise Sci Res Ctr, Sch Appl Sci, London SE1 0AA, England
关键词
tendon elongation; tendon strain; tendon stiffness; muscle strength; MORPHOLOGICAL PROPERTIES; GASTROCNEMIUS MEDIALIS; APONEUROSIS; EXCURSION; UNIT; ALGORITHM; STRAIN;
D O I
10.3390/s22072549
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The assessment of the force-length relationship under mechanical loading is widely used to evaluate the mechanical properties of tendons and to gain information about their adaptation, function, and injury. This study aimed to provide a time-efficient ultrasound method for assessing Achilles tendon mechanical properties. On two days, eleven healthy young non-active adults performed eight maximal voluntary isometric ankle plantarflexion contractions on a dynamometer with simultaneous ultrasonographic recording. Maximal tendon elongation was assessed by digitizing ultrasound images at rest and at maximal tendon force. Achilles tendon stiffness index was calculated from the ratio of tendon force-to-strain. No within- and between-day differences were detected between the proposed method and manual frame by frame tracking in Achilles tendon maximal force, maximal elongation, maximal strain, and stiffness index. The overall coefficient of variation between trials ranged from 3.4% to 10.3% and average difference in tendon tracking between methods was less than 0.6% strain. Furthermore, an additional assessment demonstrated significant differences between elite athletes, healthy young, and older adults in Achilles tendon force and stiffness index. Hence, the analysis has the potential to reliably and accurately monitor changes in Achilles tendon mechanical properties due to aging and altered mechanical loading in a time-efficient manner.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A Simplified Method for Considering Achilles Tendon Curvature in the Assessment of Tendon Elongation
    Kharazi, Mohamadreza
    Theodorakis, Christos
    Mersmann, Falk
    Arampatzis, Adamantios
    Bohm, Sebastian
    SENSORS, 2021, 21 (21)
  • [22] Reliability in the assessment of tendon volume and intratendinous signal of the Achilles tendon on MRI: a methodological description
    Shalabi, A
    Movin, T
    Kristoffersen-Wiberg, M
    Aspelin, P
    Svensson, L
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (06) : 492 - 498
  • [23] Reliability in the assessment of tendon volume and intratendinous signal of the Achilles tendon on MRI: a methodological description
    Adel Shalabi
    Tomas Movin
    Maria Kristoffersen-Wiberg
    Peter Aspelin
    Leif Svensson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 492 - 498
  • [24] DEGENERATIVE ACHILLES-TENDON DISEASE - ASSESSMENT BY MAGNETIC-RESONANCE AND ULTRASONOGRAPHY
    NEUHOLD, A
    STISKAL, M
    KAINBERGER, F
    SCHWAIGHOFER, B
    EUROPEAN JOURNAL OF RADIOLOGY, 1992, 14 (03) : 213 - 220
  • [25] Simple, reliable, and time-efficient colorimetric method for the assessment of mitochondrial function and toxicity
    Ahmad, Faraz
    Alamoudi, Widyan
    Haque, Shafiul
    Salahuddin, Mohammad
    Alsamman, Khaldoon
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2018, 18 (04) : 367 - 374
  • [26] A Time-Efficient Automatic Circuit Approximation Method
    Zhang, Ziji
    He, Yajuan
    Zhang, Bo
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2020, 67 (09) : 3047 - 3055
  • [27] Do mechanical properties of Achilles tendon influence torque steadiness?
    Johannsson, J.
    Jakobi, J.
    Duchateau, J.
    Baudry, S.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 : 1958 - 1959
  • [28] Mechanical Properties of Achilles Tendon in Rats Induced to Experimental Diabetes
    de Oliveira, Rodrigo Ribeiro
    Santos de Lira, Kamilla Dinah
    de Castro Silveira, Patricia Vercoza
    Galdino Coutinho, Marcos Paulo
    Medeiros, Marcela Nicacio
    Barboza Inacio Teixeira, Magno Felipe Holanda
    Arruda de Moraes, Silvia Regina
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (05) : 1528 - 1534
  • [29] The mechanical properties of the gibbon Achilles tendon and its role in locomotion
    Vereecke, E.
    Channon, A.
    Ker, R.
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2008, 150 (03): : S75 - S75
  • [30] Application of a thermodynamic model to mechanical properties of rabbit Achilles tendon
    Kahn, C. J. F.
    Wang, X.
    Rahouadj, R.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 : 127 - 128