Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients

被引:0
|
作者
Khoo, Phong Yue [1 ,2 ]
Lam, Chenshen [1 ,2 ]
Tang, Seng Fai [1 ,2 ,3 ]
Perera, Shamira [4 ]
Cheng, Teck Chee [1 ,2 ]
Din, Norshamsiah Md [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Fac Med, Dept Ophthalmol, Kuala Lumpur, Malaysia
[2] Hosp Canselor Tuanku Muhriz, Kuala Lumpur, Malaysia
[3] Optimax Eye Specialist Ctr, Kuala Lumpur, Malaysia
[4] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
Intraocular pressure fluctuation; iStent; Open-angle glaucoma; VISUAL-FIELD PROGRESSION; MICROBYPASS STENT IMPLANTATION; MICRO-BYPASS STENTS; CATARACT-SURGERY; RISK-FACTOR; PHACOEMULSIFICATION; SAFETY; PEAK;
D O I
10.1159/000542081
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction:This study investigated the intraocular pres-sure (IOP)fluctuation as assessed by the water drinking test(WDT) in open-angle glaucoma (OAG) patients after com-bined cataract surgery with iStent implantation.Methods:This was a prospective non-randomized comparative study.Eyes with OAG and cataracts that were planned for eithercombined phacoemulsification and iStent implantation(iStent+CS) or phacoemulsification alone (CS) were re-cruited. The iStent inject (Model G2-M-IS) or iStent injectW(Model G2-W) trabecular micro-bypass stent (GlaukosCorporation, San Clemente, CA, USA) was implanted in theiStent+CS group. WDT was performed before and 3 monthsafter surgery. WDT-IOP parameters including peak IOP, IOPfluctuation, and area under the curve (AUC) were comparedbetween the two groups.Results:Therewere20eyesintheiStent+CS group and 16 eyes in the CS group. Both groupshad similar pre-operative baseline IOP (15.6 +/- 3.7 mm Hg vs.15.8 +/- 1.8 mm Hg in the iStent+CS and CS group, re-spectively,p= 0.883). The iStent+CS group experiencedgreater numerical reduction in peak IOP (2.6 +/- 1.9 mm Hgvs. 1.9 +/- 2.4 mm Hg;p= 0.355), IOPfluctuation (1.7 +/- 2.2 mmHg vs. 0.8 +/- 2.5 mm Hg;p= 0.289), and AUC (54.8 +/- 103.6 mm Hg x minute vs. 25.3 +/- 79.0 mm Hg x minute;p=0.355) than the CS group. There was more reduction in thenumber of anti-glaucoma medications in the iStent+CSgroup (1.4 +/- 1.2) than the CS group (0.3 +/- 0.9;p=0.005).Conclusion:Both combined phacoemulsification with iS-tent inject implantation and phacoemulsification alonereduced peak IOP, IOPfluctuation, and AUC, and none ofthese parameters showed statistically significant difference.Greater reduction in anti-glaucoma medications was seen inthe combined group.(c) 2024 The Author(s).Published by S. Karger AG, Basel
引用
收藏
页码:635 / 643
页数:9
相关论文
共 50 条
  • [41] Comparison of surgical outcomes between iStent inject W implantation and microhook ab interno trabeculotomy in combination with phacoemulsification in primary open-angle glaucoma patients
    Onoe, Hiromitsu
    Hirooka, Kazuyuki
    Namiguchi, Koji
    Mizoue, Shiro
    Hosokawa, Hiroko
    Mochizuki, Hideki
    Okada, Naoki
    Tokumo, Kana
    Okumichi, Hideaki
    Kiuchi, Yoshiaki
    FRONTIERS IN MEDICINE, 2023, 10
  • [42] The Effect of Phacoemulsification on Intraocular Pressure in Medically Controlled Open-Angle Glaucoma Patients
    Slabaugh, Mark A.
    Bojikian, Karine D.
    Moore, Daniel B.
    Chen, Philip P.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (01) : 26 - 31
  • [43] Effect of combined goniotomy and phacoemulsification on intraocular pressure in open-angle glaucoma patients
    Kim, Woo-Jin
    Kim, Ju-Mi
    Lee, Woo-Hyuk
    Kim, Kyoung Nam
    Kim, Chang-sik
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 (06): : 757 - 765
  • [44] THE EFFECT OF ORAL BROMOCRIPTINE ON THE INTRAOCULAR-PRESSURE OF PATIENTS WITH OPEN-ANGLE GLAUCOMA
    WAYYES, ARM
    HASSAN, S
    RUBAIY, KM
    ABOU, YZ
    IRCS MEDICAL SCIENCE-BIOCHEMISTRY, 1986, 14 (02): : 195 - 196
  • [45] POSTURAL RESPONSE OF INTRAOCULAR-PRESSURE IN CHRONIC OPEN-ANGLE GLAUCOMA FOLLOWING TRABECULECTOMY
    PARSLEY, J
    POWELL, RG
    KEIGHTLEY, SJ
    ELKINGTON, AR
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1987, 71 (07) : 494 - 496
  • [46] COST-UTILITY ANALYSIS OF ISTENT INJECT IN MILD TO MODERATE PRIMARY OPEN-ANGLE GLAUCOMA IN JAPAN
    Igarashi, A.
    Falvey, H.
    Chu, A.
    Ueyama, M.
    Zhou, J.
    Onishi, Y.
    VALUE IN HEALTH, 2019, 22 : S671 - S671
  • [47] 12-month outcomes of trabecular microbypass iStent inject W implantation combined with cataract surgery in open-angle glaucoma eyes
    El Bakkali, Ismael Bakkali
    Arias, Pablo Cisneros
    Rivases, Guillermo Perez
    Moscarda, Eva Josefina Nunez
    De Rivas, Marta Orejudo
    Fernandez, Miguel Castillo
    Claveria, Julia Aramburu
    Martinez, Marta Suner
    Garcia, Diana Perez
    Ascaso, Javier
    Ibanez, Juan
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [48] SEQUENTIAL INTRAOCULAR PRESSURE MEASUREMENTS IN SUSPECTED OPEN-ANGLE GLAUCOMA
    钟一声
    周晓晴
    刘小红
    闵颖君
    Medical Bulletin of Shanghai Jiaotong University, 2009, (02) : 108 - 116
  • [49] Intraocular pressure and visual field progression in open-angle glaucoma
    Kass, MA
    Gordon, MO
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 490 - 491
  • [50] Effect of Different Postures on Intraocular Pressure in Open-Angle Glaucoma
    Sang, Qing
    Xin, Chen
    Yang, Diya
    Mu, Dapeng
    Wang, Ningli
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (01) : 149 - 160