Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients

被引:0
|
作者
Khoo, Phong Yue [1 ,2 ]
Lam, Chenshen [1 ,2 ]
Tang, Seng Fai [1 ,2 ,3 ]
Perera, Shamira [4 ]
Cheng, Teck Chee [1 ,2 ]
Din, Norshamsiah Md [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Fac Med, Dept Ophthalmol, Kuala Lumpur, Malaysia
[2] Hosp Canselor Tuanku Muhriz, Kuala Lumpur, Malaysia
[3] Optimax Eye Specialist Ctr, Kuala Lumpur, Malaysia
[4] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
Intraocular pressure fluctuation; iStent; Open-angle glaucoma; VISUAL-FIELD PROGRESSION; MICROBYPASS STENT IMPLANTATION; MICRO-BYPASS STENTS; CATARACT-SURGERY; RISK-FACTOR; PHACOEMULSIFICATION; SAFETY; PEAK;
D O I
10.1159/000542081
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction:This study investigated the intraocular pres-sure (IOP)fluctuation as assessed by the water drinking test(WDT) in open-angle glaucoma (OAG) patients after com-bined cataract surgery with iStent implantation.Methods:This was a prospective non-randomized comparative study.Eyes with OAG and cataracts that were planned for eithercombined phacoemulsification and iStent implantation(iStent+CS) or phacoemulsification alone (CS) were re-cruited. The iStent inject (Model G2-M-IS) or iStent injectW(Model G2-W) trabecular micro-bypass stent (GlaukosCorporation, San Clemente, CA, USA) was implanted in theiStent+CS group. WDT was performed before and 3 monthsafter surgery. WDT-IOP parameters including peak IOP, IOPfluctuation, and area under the curve (AUC) were comparedbetween the two groups.Results:Therewere20eyesintheiStent+CS group and 16 eyes in the CS group. Both groupshad similar pre-operative baseline IOP (15.6 +/- 3.7 mm Hg vs.15.8 +/- 1.8 mm Hg in the iStent+CS and CS group, re-spectively,p= 0.883). The iStent+CS group experiencedgreater numerical reduction in peak IOP (2.6 +/- 1.9 mm Hgvs. 1.9 +/- 2.4 mm Hg;p= 0.355), IOPfluctuation (1.7 +/- 2.2 mmHg vs. 0.8 +/- 2.5 mm Hg;p= 0.289), and AUC (54.8 +/- 103.6 mm Hg x minute vs. 25.3 +/- 79.0 mm Hg x minute;p=0.355) than the CS group. There was more reduction in thenumber of anti-glaucoma medications in the iStent+CSgroup (1.4 +/- 1.2) than the CS group (0.3 +/- 0.9;p=0.005).Conclusion:Both combined phacoemulsification with iS-tent inject implantation and phacoemulsification alonereduced peak IOP, IOPfluctuation, and AUC, and none ofthese parameters showed statistically significant difference.Greater reduction in anti-glaucoma medications was seen inthe combined group.(c) 2024 The Author(s).Published by S. Karger AG, Basel
引用
收藏
页码:635 / 643
页数:9
相关论文
共 50 条
  • [31] Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma
    S Srinivasan
    N S Choudhari
    M Baskaran
    R J George
    B Shantha
    L Vijaya
    Eye, 2016, 30 : 362 - 368
  • [32] Diurnal intraocular pressure fluctuation and its risk factors in angle-closure and open-angle glaucoma
    Srinivasan, S.
    Choudhari, N. S.
    Baskaran, M.
    George, R. J.
    Shantha, B.
    Vijaya, L.
    EYE, 2016, 30 (03) : 362 - 368
  • [33] The dynamics of the cornea, intraocular pressure, and open-angle glaucoma
    de Vries, Victor
    Klaver, Caroline C. W.
    Ramdas, Wishal D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [34] Phacoemulsification and intraocular lens implantation in eyes with open-angle glaucoma
    Pohjalainen, T
    Vesti, E
    Uusitalo, RJ
    Laatikainen, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (03): : 313 - 316
  • [35] Intraocular pressure after phacoemulsification with posterior chamber lens implantation in open-angle glaucoma
    Hudovernik, M
    Pahor, D
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (12) : 835 - 839
  • [36] Dampening of Diurnal Intraocular Pressure Fluctuation by Combined Trabeculotomy and Sinusotomy in Eyes With Open-angle Glaucoma
    Matsuoka, Masato
    Ando, Akira
    Minamino, Keizo
    Matsuyama, Kayako
    Shima, Chieko
    Matsumura, Miyo
    Nishimura, Tetsuya
    JOURNAL OF GLAUCOMA, 2013, 22 (04) : 290 - 293
  • [37] Evaluation of the Efficacy and Safety of Canaloplasty and iStent Bypass Implantation in Patients with Open-Angle Glaucoma: A Review of the Literature
    Golaszewska, Kinga
    Konopinska, Joanna
    Obuchowska, Iwona
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (21)
  • [38] Efficacy of Selective Laser Trabeculoplasty after iStent Implantation in Primary Open-Angle Glaucoma
    Siedlecki, Adam R.
    Hicks, Patrice M.
    Haaland, Benjamin
    DeAngelis, Margaret M.
    Sieminski, Sandra F.
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (08):
  • [39] Treatment of Open-Angle Glaucoma with iStent Implantation Combined with Phacoemulsification in Polish Caucasian Population
    Kozera, Milena
    Konopinska, Joanna
    Mariak, Zofia
    Rekas, Marek
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 473 - 480
  • [40] Kahook Dual Blade Goniotomy vs iStent inject: Long-Term Results in Patients with Open-Angle Glaucoma
    Arnljots, Thorsteinn S.
    Economou, Mario A.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 541 - 550