Intraocular Pressure Fluctuation as Assessed by Water Drinking Test following iStent Inject Implantation in Open-Angle Glaucoma Patients

被引:0
|
作者
Khoo, Phong Yue [1 ,2 ]
Lam, Chenshen [1 ,2 ]
Tang, Seng Fai [1 ,2 ,3 ]
Perera, Shamira [4 ]
Cheng, Teck Chee [1 ,2 ]
Din, Norshamsiah Md [1 ,2 ]
机构
[1] Univ Kebangsaan Malaysia, Med Ctr, Fac Med, Dept Ophthalmol, Kuala Lumpur, Malaysia
[2] Hosp Canselor Tuanku Muhriz, Kuala Lumpur, Malaysia
[3] Optimax Eye Specialist Ctr, Kuala Lumpur, Malaysia
[4] Singapore Natl Eye Ctr, Singapore, Singapore
关键词
Intraocular pressure fluctuation; iStent; Open-angle glaucoma; VISUAL-FIELD PROGRESSION; MICROBYPASS STENT IMPLANTATION; MICRO-BYPASS STENTS; CATARACT-SURGERY; RISK-FACTOR; PHACOEMULSIFICATION; SAFETY; PEAK;
D O I
10.1159/000542081
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction:This study investigated the intraocular pres-sure (IOP)fluctuation as assessed by the water drinking test(WDT) in open-angle glaucoma (OAG) patients after com-bined cataract surgery with iStent implantation.Methods:This was a prospective non-randomized comparative study.Eyes with OAG and cataracts that were planned for eithercombined phacoemulsification and iStent implantation(iStent+CS) or phacoemulsification alone (CS) were re-cruited. The iStent inject (Model G2-M-IS) or iStent injectW(Model G2-W) trabecular micro-bypass stent (GlaukosCorporation, San Clemente, CA, USA) was implanted in theiStent+CS group. WDT was performed before and 3 monthsafter surgery. WDT-IOP parameters including peak IOP, IOPfluctuation, and area under the curve (AUC) were comparedbetween the two groups.Results:Therewere20eyesintheiStent+CS group and 16 eyes in the CS group. Both groupshad similar pre-operative baseline IOP (15.6 +/- 3.7 mm Hg vs.15.8 +/- 1.8 mm Hg in the iStent+CS and CS group, re-spectively,p= 0.883). The iStent+CS group experiencedgreater numerical reduction in peak IOP (2.6 +/- 1.9 mm Hgvs. 1.9 +/- 2.4 mm Hg;p= 0.355), IOPfluctuation (1.7 +/- 2.2 mmHg vs. 0.8 +/- 2.5 mm Hg;p= 0.289), and AUC (54.8 +/- 103.6 mm Hg x minute vs. 25.3 +/- 79.0 mm Hg x minute;p=0.355) than the CS group. There was more reduction in thenumber of anti-glaucoma medications in the iStent+CSgroup (1.4 +/- 1.2) than the CS group (0.3 +/- 0.9;p=0.005).Conclusion:Both combined phacoemulsification with iS-tent inject implantation and phacoemulsification alonereduced peak IOP, IOPfluctuation, and AUC, and none ofthese parameters showed statistically significant difference.Greater reduction in anti-glaucoma medications was seen inthe combined group.(c) 2024 The Author(s).Published by S. Karger AG, Basel
引用
收藏
页码:635 / 643
页数:9
相关论文
共 50 条
  • [21] Combined iStent® Inject Trabecular Micro-Bypass and Phacoemulsification in Australian Patients with Open-Angle Glaucoma
    Salby, Alon M.
    Skalicky, Simon E.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 985 - 993
  • [22] COMBINED ISTENT® INJECT TRABECULAR MICRO-BYPASS AND PHACOEMULSIFICATION IN AUSTRALIAN PATIENTS WITH OPEN-ANGLE GLAUCOMA
    Salby, Alon
    Skalicky, Simon
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 102 - 102
  • [23] Posture-Induced Intraocular Pressure Changes after iStent Inject W Combined with Phacoemulsification in Open Angle Glaucoma Patients
    Iwasaki, Kentaro
    Arimura, Shogo
    Orii, Yusuke
    Inatani, Masaru
    MEDICINA-LITHUANIA, 2023, 59 (03):
  • [24] Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma
    Chen, Yu-Yen
    Lai, Yun-Ju
    Yen, Yung-Feng
    Huang, Li-Ying
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [25] Minimally invasive glaucoma surgery: comparison of Hydrus microstent with iStent inject in primary open-angle glaucoma
    Komzak, Krishna
    Allen, Penelope L.
    Toh, Tze'Yo
    BMJ OPEN OPHTHALMOLOGY, 2025, 10 (01):
  • [26] Seasonal fluctuation in intraocular pressure and its associated factors in primary open-angle glaucoma
    Ryo Terauchi
    Shumpei Ogawa
    Akiko Sotozono
    Takahiko Noro
    Masayuki Tatemichi
    Tadashi Nakano
    Eye, 2021, 35 : 3325 - 3332
  • [27] Seasonal fluctuation in intraocular pressure and its associated factors in primary open-angle glaucoma
    Terauchi, Ryo
    Ogawa, Shumpei
    Sotozono, Akiko
    Noro, Takahiko
    Tatemichi, Masayuki
    Nakano, Tadashi
    EYE, 2021, 35 (12) : 3325 - 3332
  • [28] Intraocular Pressure Fluctuation in Primary Open-Angle Glaucoma with Canaloplasty and Microcatheter Assisted Trabeculotomy
    Xin, Chen
    Wang, Ningli
    Wang, Huaizhou
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [29] Effect of Trabeculectomy on Intraocular Pressure Fluctuation With Postural Change in Eyes With Open-angle Glaucoma
    Hirooka, Kazuyuki
    Takenaka, Hirokazu
    Baba, Tetsuya
    Takagishi, Mai
    Mizote, Masanori
    Shiraga, Fumio
    JOURNAL OF GLAUCOMA, 2009, 18 (09) : 689 - 691