Indoor tests on the mechanical response of tunnel lining under the influence of pipeline leakage

被引:0
|
作者
Zhang, Sulei [1 ]
Li, Linghui [1 ]
Chen, Xiaofei [1 ]
Liu, Chang [1 ]
Du, Mingqing [1 ]
Zhang, Yongjun [1 ]
机构
[1] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
基金
中国国家自然科学基金;
关键词
Subway tunnel; Pipeline leakage; Indoor test; Mechanical response; Lining structure; UNDERGROUND CAVITIES; CITY;
D O I
10.1016/j.engfailanal.2025.109501
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pipeline leakage is a common issue encountered in urban areas, significantly contributing to the deterioration of tunnel structures and even posing a risk of ground collapse. This study investigates the mechanical response of tunnel structures influenced by adjacent pipeline leakages through indoor tests. A scaled tunnel model with a simulated lining system was constructed, and pipeline leakage scenarios were replicated by introducing controlled water pressures at the predefined location. The deformation and stress redistribution in the lining under varying leakage locations and durations were monitored. Experimental results reveal that the location of the pipeline leakage concerning the tunnel had a great impact on the distribution of the leakage zone. The presence of the tunnel affected the expansion of seepage water from the pipeline in the strata. The pipe leakage above the tunnel resulted in a maximum surface settlement of 2.66 mm, whereas the horizontal movement of the pipe leakage location reduced the surface settlement by 10-15 %. Change in location of pipeline leakage induced uneven deformation of the strata, and the settlement progression behavior exhibited an initial gradual development stage (0-2 h), accelerated subsidence stage (2-10 h), and stabilization stage (10-14 h). Uniform settlement of the strata due to pipeline leakage led to a dynamic mechanical response of the lining structure, and the internal forces of the lining structure also manifested obvious asymmetric features. Lining leakage resulted in a 41.9 % and 22.1 % increase in bending moment and axial force of the lining structure, respectively. The lining structure bias caused by pipeline leakage will deteriorate the mechanical behavior of the tunnel structure. The findings of this paper can provide a reference for the prevention and control of leakage of adjacent pipelines in subway tunnels.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Centrifugal model tests on behavior of soil and tunnel under underground water leakage
    Tian G.
    Liu S.
    Zhang G.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2023, 45 : 226 - 229
  • [32] The influence on lining moment of tunnel under the local weakening of structural strength of loess
    Li, Rongjian
    Zheng, Wen
    Fang, Juan
    Che, Gaofeng
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3872 - 3875
  • [33] Influence of lining section type on a tunnel structure under active fault movement
    Liu, Xuezeng, 1600, Editorial By Modern Tunnelling Technology, China (51):
  • [34] Dynamical Response of Circular Tunnel with Steel Lining under the Action of Blasting Vibration
    Yi, Changping
    Lu, Wenbo
    Feng, Ling
    Wang, Gang
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4037 - +
  • [35] The Influence Law of Blasting Dynamic Response of Adjacent Existing Railway Tunnel Lining
    Guo, Yunlong
    Meng, Haili
    Sun, Cuiyuan
    Liu, Yiwei
    Xue, Li
    Deng, Nitao
    Zhongguo Tiedao Kexue/China Railway Science, 2023, 44 (06): : 103 - 112
  • [36] Dynamical response of circular tunnel with steel lining under the action of blasting vibration
    School of Resources and Environment Engineering, Wuhan University of Technology, Wuhan 430070, China
    不详
    Adv. Mater. Res., (4037-4042):
  • [37] Mechanical Response Analysis and Safety Assessment of Shallow-Buried Pipeline under the Influence of Mining
    Cao, Zhengzheng
    Zhou, Yuejin
    Xu, Ping
    Li, Jiawei
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2014, 101 (05): : 351 - 364
  • [38] Analysis of mechanical characteristic of shield tunnel segments lining and its influence during construction
    Ye Fei
    He Chuan
    Wang Shi-min
    ROCK AND SOIL MECHANICS, 2011, 32 (06) : 1801 - +
  • [39] Influence of different leakage positions of tunnel on surrounding soils and parallel tunnel under disaster environment
    Zheng, Gang
    Dai, Xuan
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2015, 34 : 3196 - 3207
  • [40] Evaluation of the Mechanical Response of Tunnel Lining Induced by Reverse Faulting Using Numerical Simulations
    Aghamolaei, Milad
    Azizkandi, Alireza Saeedi
    Khorashadizadeh, Moein
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2023, 21 (11) : 1739 - 1750