Indoor tests on the mechanical response of tunnel lining under the influence of pipeline leakage

被引:0
|
作者
Zhang, Sulei [1 ]
Li, Linghui [1 ]
Chen, Xiaofei [1 ]
Liu, Chang [1 ]
Du, Mingqing [1 ]
Zhang, Yongjun [1 ]
机构
[1] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
基金
中国国家自然科学基金;
关键词
Subway tunnel; Pipeline leakage; Indoor test; Mechanical response; Lining structure; UNDERGROUND CAVITIES; CITY;
D O I
10.1016/j.engfailanal.2025.109501
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pipeline leakage is a common issue encountered in urban areas, significantly contributing to the deterioration of tunnel structures and even posing a risk of ground collapse. This study investigates the mechanical response of tunnel structures influenced by adjacent pipeline leakages through indoor tests. A scaled tunnel model with a simulated lining system was constructed, and pipeline leakage scenarios were replicated by introducing controlled water pressures at the predefined location. The deformation and stress redistribution in the lining under varying leakage locations and durations were monitored. Experimental results reveal that the location of the pipeline leakage concerning the tunnel had a great impact on the distribution of the leakage zone. The presence of the tunnel affected the expansion of seepage water from the pipeline in the strata. The pipe leakage above the tunnel resulted in a maximum surface settlement of 2.66 mm, whereas the horizontal movement of the pipe leakage location reduced the surface settlement by 10-15 %. Change in location of pipeline leakage induced uneven deformation of the strata, and the settlement progression behavior exhibited an initial gradual development stage (0-2 h), accelerated subsidence stage (2-10 h), and stabilization stage (10-14 h). Uniform settlement of the strata due to pipeline leakage led to a dynamic mechanical response of the lining structure, and the internal forces of the lining structure also manifested obvious asymmetric features. Lining leakage resulted in a 41.9 % and 22.1 % increase in bending moment and axial force of the lining structure, respectively. The lining structure bias caused by pipeline leakage will deteriorate the mechanical behavior of the tunnel structure. The findings of this paper can provide a reference for the prevention and control of leakage of adjacent pipelines in subway tunnels.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Evaluation of reverse faulting effects on the mechanical response of tunnel lining using centrifuge tests and numerical analysis
    Baziar, Mohammad Hassan
    Nabizadeh, Ali
    Khalafian, Nader
    Lee, Chung Jung
    Hung, Wen Yi
    GEOTECHNIQUE, 2020, 70 (06): : 490 - 502
  • [12] Study on the Response of Tunnel Lining under Fault Dislocation
    Bao, Liangliang
    Wei, Feng
    SUSTAINABILITY, 2023, 15 (06)
  • [13] Mechanical response of shield tunnel lining under nonlinear wave and current action in sloping seabed
    Zhang, Zhiguo
    Han, Yangyang
    Lv, Xilin
    Chen, Jinpeng
    Pan, Yutao
    Ni, Yin
    INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS, 2024, 48 (02) : 419 - 462
  • [14] Shaking Table Tests on Seismic Response of Tunnel with Longitudinal Cracking Lining
    Li B.
    Qiu W.
    Qi X.
    Deng Z.
    Hu H.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2021, 56 (01): : 20 - 27and55
  • [15] Study on the Mechanical Response Mechanism and Damage Behavior of a Tunnel Lining Structure under Reverse Fault Dislocation
    Su, Huifeng
    Zhao, Zhongxiao
    Meng, Kun
    Zhao, Shuo
    BUILDINGS, 2022, 12 (10)
  • [16] Research on dynamic response of orthogonal tunnel lining under earthquake
    Yang, Chen
    Lu, Zelin
    Wang, Yinwen
    EARTHQUAKES AND STRUCTURES, 2024, 27 (06) : 517 - 528
  • [17] Influence of voids behind lining on the mechanical behavior of lining structure of highway tunnel in watery strata
    Fang Y.
    Guo J.
    Kang H.
    Xu C.
    1648, Academia Sinica (35): : 1648 - 1658
  • [18] Model test study on the mechanical response of the deep buried tunnel lining
    Duan, Longyan
    Feng, Jimeng
    Song, Jiadai
    Yao, Shiyu
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [19] Influence of Pipeline Leakage on the Ground Settlement around the Tunnel during Shield Tunneling
    Shi, Xin
    Cao, Yi
    Rong, Chuanxin
    An, Gangjian
    Wang, Houliang
    Cui, Linzhao
    SUSTAINABILITY, 2022, 14 (24)
  • [20] Study on the Mechanical Response of a Dense Pipeline Adjacent to the Shallow Tunnel
    Wu B.
    Zheng W.
    Guo F.
    Xu S.
    Zhu W.
    Xu B.
    Zhang Y.
    Advances in Materials Science and Engineering, 2023, 2023