Indoor tests on the mechanical response of tunnel lining under the influence of pipeline leakage

被引:0
|
作者
Zhang, Sulei [1 ]
Li, Linghui [1 ]
Chen, Xiaofei [1 ]
Liu, Chang [1 ]
Du, Mingqing [1 ]
Zhang, Yongjun [1 ]
机构
[1] Qingdao Univ Technol, Sch Civil Engn, Qingdao 266033, Peoples R China
基金
中国国家自然科学基金;
关键词
Subway tunnel; Pipeline leakage; Indoor test; Mechanical response; Lining structure; UNDERGROUND CAVITIES; CITY;
D O I
10.1016/j.engfailanal.2025.109501
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pipeline leakage is a common issue encountered in urban areas, significantly contributing to the deterioration of tunnel structures and even posing a risk of ground collapse. This study investigates the mechanical response of tunnel structures influenced by adjacent pipeline leakages through indoor tests. A scaled tunnel model with a simulated lining system was constructed, and pipeline leakage scenarios were replicated by introducing controlled water pressures at the predefined location. The deformation and stress redistribution in the lining under varying leakage locations and durations were monitored. Experimental results reveal that the location of the pipeline leakage concerning the tunnel had a great impact on the distribution of the leakage zone. The presence of the tunnel affected the expansion of seepage water from the pipeline in the strata. The pipe leakage above the tunnel resulted in a maximum surface settlement of 2.66 mm, whereas the horizontal movement of the pipe leakage location reduced the surface settlement by 10-15 %. Change in location of pipeline leakage induced uneven deformation of the strata, and the settlement progression behavior exhibited an initial gradual development stage (0-2 h), accelerated subsidence stage (2-10 h), and stabilization stage (10-14 h). Uniform settlement of the strata due to pipeline leakage led to a dynamic mechanical response of the lining structure, and the internal forces of the lining structure also manifested obvious asymmetric features. Lining leakage resulted in a 41.9 % and 22.1 % increase in bending moment and axial force of the lining structure, respectively. The lining structure bias caused by pipeline leakage will deteriorate the mechanical behavior of the tunnel structure. The findings of this paper can provide a reference for the prevention and control of leakage of adjacent pipelines in subway tunnels.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Laboratory tests on mechanical characteristics of fully and partially wrapped waterproof systems for tunnel lining
    Wang, Xiu-Ying
    Tan, Zhong-Sheng
    Li, Jian
    Du, Chao-Wei
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2012, 34 (04): : 654 - 659
  • [22] Experimental Research on the Pipeline - soil Deformation Caused by Shield under the Influence of Pipeline Leakage
    Shi, Xin
    Rong, Chuanxin
    Wang, Houliang
    Sun, Xuejun
    Cui, Linzhao
    Cheng, Hua
    Cai, Haibing
    Journal of Railway Engineering Society, 2023, 40 (05) : 110 - 115
  • [23] Response Characteristics of Cross Tunnel Lining under Dynamic Train Load
    Wang, Ang
    Shi, Cheng-hua
    Zhao, Chenyang
    Deng, E.
    Yang, Weichao
    He, Hong
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [24] Response analysis of tunnel lining structure under impact and fire loading
    Zhang, Qian
    Wang, Wen-yu
    Bai, Song-song
    Tan, Ying-hua
    ADVANCES IN MECHANICAL ENGINEERING, 2019, 11 (03)
  • [25] Analysis of Mechanical Characteristics of Karst Tunnel Lining Structure Under Heavy Rainfall
    Wan F.
    Li K.-J.
    Wang H.-L.
    Zhang X.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2023, 36 (11): : 312 - 322
  • [26] Study on the Influence of Crystal Plugging on the Mechanical Behavior of Karst Tunnel Lining Structure
    Wang, Yehao
    Liu, Shiyang
    Zhang, Li
    Guan, Shaojie
    Li, Zongzhi
    Cheng, Liang
    Liu, Jie
    Chen, Jie
    PROCESSES, 2025, 13 (02)
  • [27] Experimental study on mechanical behaviors of tunnel lining under and after fire scenarios
    Yan, Z. G.
    Zhu, H. H.
    UNDERGROUND SPACE - THE 4TH DIMENSION OF METROPOLISES, VOLS 1-3, 2007, : 1805 - 1809
  • [28] Research on Deterioration of Mechanical Properties of Tunnel Lining Structure under Reinforcement Corrosion
    Li Y.
    Liu X.
    Zhu X.
    Tang X.
    Zhang Z.
    Tiedao Xuebao/Journal of the China Railway Society, 2024, 46 (01): : 156 - 163
  • [29] Influence of novel polymer waterproofing membrane on mechanical properties of tunnel lining structure
    Jiang, Yajun
    He, Bin
    Zhao, Jumei
    Pei, Huqiang
    Liu, Jitai
    Wang, Huqun
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 360
  • [30] Analysis of the influence of the thickness insufficiency in secondary lining on the mechanical properties of Double-layer lining of shield tunnel
    Wang, Shimin
    Wang, Ya
    Lin, Zhiyu
    Song, Zihan
    Wang, Xianming
    Peng, Xiaoyu
    ENGINEERING FAILURE ANALYSIS, 2022, 141