Comparison of the C-MAC D-Blade Video Laryngoscope and the McCoy Laryngoscope in Difficult Airway Patients According to Arne Multivariate Risk Classification: A Randomised Prospective Trial

被引:0
|
作者
Duran, M. [1 ]
Yilmaz, N. [1 ]
Tepe, M. [1 ]
Kaya, R. [2 ]
Dogukan, M. [1 ]
Nakir, H. [3 ]
Magac, M. S. [4 ]
机构
[1] Adiyaman Univ, Fac Med, Dept Anesthesiol & Reanimat, Adiyaman, Turkiye
[2] Private Yeni Hayat Hosp, Dept Anesthesiol & Reanimat, Osmaniye, Turkiye
[3] Nazilli State Hosp, Dept Anesthesiol & Reanimat, Aydin, Turkiye
[4] Balikesir State Hosp, Dept Anesthesiol & Reanimat, Balikesir, Turkiye
关键词
C-MAC D-blade video laryngoscope; difficult airway; McCoy laryngoscope; TRACHEAL INTUBATION; MANAGEMENT; BOUGIE;
D O I
10.4103/njcp.njcp_422_24
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Difficult intubation is an important cause of morbidity and mortality during anaesthesia. Detection of patient with difficult airway is very important. Arne multivariate risk classification score is one of the tests that is used to detect this difficult airway patients. McCoy direct laryngoscope and the C-MAC videolaryngoscope are parts of among the tools that are currently used for these patients. Aim:This study aimed to compare the intubation success and access the quality of difficult airway using the McCoy direct laryngoscope and the C-MAC video laryngoscope. Methods:Included in this study were 100 patients scheduled for elective surgery, ASA I-III, who had the Arne multivariate risk classification score >11. The patients were randomly divided into the C-MAC D-Blade video laryngoscope (n = 50) and the McCoy laryngoscope (n = 50). The Mallampati score, Arne multivariate score, intubation success, required time for intubation, number of intubation attempts, required time to visualize the glottis, need for auxiliary equipment, and complications were recorded. Results:No differences in the demographic data were observed between the two groups (P > 0.05). In addition, no differences were observed between the groups in the required time to visualize the glottis (P = 0.801) or the Arne score (P = 0.619). The rate of use of gum elastic bougies in Grup C-MAC was lower (P = 0.014), and the intubation success rate was higher during the first attempt (P = 0.016). The intubation time was longer in the McCoy group (P = 0.017). Conclusion:The C-MAC D-Blade video laryngoscope was superior to the McCoy direct laryngoscope for difficult-to-intubate patients due to the shorter required time for intubation, higher intubation success rate, and lesser need for auxiliary equipment.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [21] Comparison of C-MAC Miller blade video laryngoscope with conventional Miller blade in infants undergoing elective surgery- A prospective randomised trial
    Manhas, Samriti
    Agrawal, Nidhi
    Jain, Swati
    Sharma, Ridhima
    Choudhary, Ripon
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (14) : 133 - 139
  • [22] Comparison of C-MAC Miller blade video laryngoscope with conventional Miller blade in infants undergoing elective surgery- A prospective randomised trial
    Manhas, Samriti
    Agrawal, Nidhi
    Jain, Swati
    Sharma, Ridhima
    Choudhary, Ripon
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 : S133 - S139
  • [23] Randomised Comparative Study between C-MAC D Blade and McCoy Blade Laryngoscope for Intubation with Manual Inline Axial Stabilisation
    Mohan, Athmanathan
    Venkatatesh, Ranjan R.
    George, Sagiev Koshy
    Paul, Anju Annie
    Alfred, Vinu Mervick
    Ninan, Leenu Grace
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (01) : UC06 - UC9
  • [24] Learning curve and performance in simulated difficult airway for the novel C-MAC® video-stylet and C-MAC® Macintosh video laryngoscope: A prospective randomized manikin trial
    Pius, James
    Noppens, Ruediger R.
    PLOS ONE, 2020, 15 (11):
  • [25] C-MAC (R) video laryngoscope with D-BLADE (TM) and Frova introducer for awake intubation in a patient with parapharyngeal mass
    Vinayagam, S.
    Dhanger, S.
    Tilak, P.
    Gnanasekar, R.
    SAUDI JOURNAL OF ANAESTHESIA, 2016, 10 (04) : 471 - 473
  • [26] Comparison of the C-MAC video laryngoscope to the Macintosh laryngoscope for intubation of blunt trauma patients in the ED
    Goksu, Erkan
    Kilic, Taylan
    Yildiz, Gunay
    Unal, Aslihan
    Kartal, Mutlu
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2016, 16 (02) : 53 - 56
  • [27] Management of a Difficult Airway Scenario in a Case of Hurler's Syndrome with a D-Blade Video Laryngoscope
    Thakkar, Keta D.
    Hrishi, Ajay P.
    Sethuraman, Manikandan
    Vimala, Smita
    JOURNAL OF NEUROANAESTHESIOLOGY AND CRITICAL CARE, 2021, 08 (03) : 214 - 216
  • [28] Comparison of the C-MAC video laryngoscope size 2 Macintosh blade with size 2 C-MAC D-Blade for laryngoscopy and endotracheal intubation in children with simulated cervical spine injury: A prospective randomized crossover study
    Sinha, Renu
    Ray, Bikash Ranjan
    Sharma, Ankur
    Pandey, Ravinder Kumar
    Punj, Jyotsna
    Darlong, Vanlalnghaka
    Trikha, Anjan
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (04) : 509 - 514
  • [29] A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope
    Choi, Hyun Young
    Oh, Young Min
    Kang, Gu Hyun
    Kang, Hyunggoo
    Jang, Yong Soo
    Kim, Wonhee
    Kim, Euichung
    Cho, Young Soon
    Choi, Hyukjoong
    Kim, Hyunjong
    Kim, Gyoung Yong
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [30] Prospective Trial to Compare Direct and Indirect Laryngoscopy Using C-MAC PM® with Macintosh Blade and D-Blade® in a Simulated Difficult Airway
    Raimann, Florian Juergen
    Dietze, Philipp Edmund
    Cuca, Colleen Elizabeth
    Meininger, Dirk
    Kessler, Paul
    Byhahn, Christian
    Gill-Schuster, Daniel
    Zacharowski, Kai
    Mutlak, Haitham
    EMERGENCY MEDICINE INTERNATIONAL, 2019, 2019