Comparison of the C-MAC D-Blade Video Laryngoscope and the McCoy Laryngoscope in Difficult Airway Patients According to Arne Multivariate Risk Classification: A Randomised Prospective Trial

被引:0
|
作者
Duran, M. [1 ]
Yilmaz, N. [1 ]
Tepe, M. [1 ]
Kaya, R. [2 ]
Dogukan, M. [1 ]
Nakir, H. [3 ]
Magac, M. S. [4 ]
机构
[1] Adiyaman Univ, Fac Med, Dept Anesthesiol & Reanimat, Adiyaman, Turkiye
[2] Private Yeni Hayat Hosp, Dept Anesthesiol & Reanimat, Osmaniye, Turkiye
[3] Nazilli State Hosp, Dept Anesthesiol & Reanimat, Aydin, Turkiye
[4] Balikesir State Hosp, Dept Anesthesiol & Reanimat, Balikesir, Turkiye
关键词
C-MAC D-blade video laryngoscope; difficult airway; McCoy laryngoscope; TRACHEAL INTUBATION; MANAGEMENT; BOUGIE;
D O I
10.4103/njcp.njcp_422_24
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Difficult intubation is an important cause of morbidity and mortality during anaesthesia. Detection of patient with difficult airway is very important. Arne multivariate risk classification score is one of the tests that is used to detect this difficult airway patients. McCoy direct laryngoscope and the C-MAC videolaryngoscope are parts of among the tools that are currently used for these patients. Aim:This study aimed to compare the intubation success and access the quality of difficult airway using the McCoy direct laryngoscope and the C-MAC video laryngoscope. Methods:Included in this study were 100 patients scheduled for elective surgery, ASA I-III, who had the Arne multivariate risk classification score >11. The patients were randomly divided into the C-MAC D-Blade video laryngoscope (n = 50) and the McCoy laryngoscope (n = 50). The Mallampati score, Arne multivariate score, intubation success, required time for intubation, number of intubation attempts, required time to visualize the glottis, need for auxiliary equipment, and complications were recorded. Results:No differences in the demographic data were observed between the two groups (P > 0.05). In addition, no differences were observed between the groups in the required time to visualize the glottis (P = 0.801) or the Arne score (P = 0.619). The rate of use of gum elastic bougies in Grup C-MAC was lower (P = 0.014), and the intubation success rate was higher during the first attempt (P = 0.016). The intubation time was longer in the McCoy group (P = 0.017). Conclusion:The C-MAC D-Blade video laryngoscope was superior to the McCoy direct laryngoscope for difficult-to-intubate patients due to the shorter required time for intubation, higher intubation success rate, and lesser need for auxiliary equipment.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [31] Comparison of propofol versus dexmedetomidine sedation for awake C-MAC® D-Blade video laryngoscopic nasotracheal intubation in patients with difficult airway: A randomised clinical study
    Vishnoi, Gunjan
    Shah, Shagun B.
    Chawla, Rajiv
    Bhardwaj, Manoj
    Patel, Anil
    Arora, Jenna
    INDIAN JOURNAL OF ANAESTHESIA, 2024, 68 (08) : 699 - 705
  • [32] Factors Influencing the Time of Intubation Using C-MAC D-Blade? Video Laryngoscope: An Observational Cross-Sectional Study
    Gayathri, Balasubramaniam
    Mani, Karthik
    Vishak, Manoj
    John, Joy
    Srinivasan, Raghul G.
    Mirunalini, Gunaseelan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [33] Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway
    Byhahn, C.
    Iber, T.
    Zacharowski, K.
    Weber, C. F.
    Ruesseler, M.
    Schalk, R.
    Meininger, D.
    MINERVA ANESTESIOLOGICA, 2010, 76 (08) : 577 - 583
  • [34] Comparison of Different Types of Stylets with No-Stylet Technique for Intubation with C-MAC D-Blade® Videolaryngoscope in Simulated Difficult Airway: A Prospective Randomised Study
    Goel, Rishika
    Anand, Lakesh Kumar
    Singh, Manpreet
    Jindal, Swati
    Rani, Mala
    Kaur, Arshdeep
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (06) : 445 - 452
  • [35] Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway
    Aziz, Michael F.
    Dillman, Dawn
    Fu, Rongwei
    Brambrink, Ansgar M.
    ANESTHESIOLOGY, 2012, 116 (03) : 629 - 636
  • [36] Comparison of the C-MAC D-Blade, Conventional C-MAC, and Macintosh Laryngoscopes in Simulated Easy and Difficult Airways
    Kilicaslan, Alper
    Topal, Ahmet
    Erol, Atilla
    Uzun, Sema Tuncer
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (04) : 182 - 189
  • [37] Comparison of aerosol box intubation with C-MAC video laryngoscope and direct laryngoscopy-A randomised controlled trial
    Puthenveettil, Nitu
    Rahman, Sajan
    Vijayaraghavan, Sundeep
    Suresh, Sneha
    Kadapamannil, Dilesh
    Paul, Jerry
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (02) : 133 - 138
  • [38] C-MAC D-Blade video laryngoscope for awake double lumen tube placement: A case report (vol 18, pg 34, 2018)
    Mittal, A. K.
    Goel, N.
    Dubey, J.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2021, 38 : 49 - 49
  • [39] Comparison of the Success of Two Techniques for the Endotracheal Intubation with C-MAC Video Laryngoscope Miller Blade in Children: A Prospective Randomized Study
    Sinha, Renu
    Sharma, Ankur
    Ray, Bikash Ranjan
    Pandey, Ravinder Kumar
    Darlong, Vanlalnghka
    Punj, Jyotsna
    Chandralekha, Chandralekha
    Upadhyay, Ashish Datt
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2016, 2016
  • [40] A comparison of King vision video laryngoscope with CMAC D-blade in obese patients with anticipated difficult airway in tertiary hospital in India - Randomized control study
    Sahajanandan, Raj
    Dhanyee, Anity Singh
    Gautam, Arun Kumar
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2019, 35 (03) : 363 - 367