Optimal screw orientation for fixation of coronal shear fractures: a biomechanical comparison

被引:0
|
作者
Lappen, Sebastian [1 ]
Siebenlist, Sebastian [1 ]
Leschinger, Tim [2 ,3 ]
Kadantsev, Pavel [1 ]
Geyer, Stephanie [1 ,4 ]
Wegmann, Kilian [2 ,3 ,5 ]
Mueller, Lars-Peter
Hackl, Michael [2 ,3 ]
机构
[1] Tech Univ Munich, Dept Sports Orthopead, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Univ Cologne, Fac Med, Ctr Orthoped & Trauma Surg, Cologne, Germany
[3] Univ Cologne, Univ Hosp, Ctr Orthoped & Trauma Surg, Cologne, Germany
[4] St Vinzenz Klin, Dept Orthoped, Pfronten, Germany
[5] OCM Orthopad Chirurg Munchen Clin, Munich, Germany
关键词
Capitellum; distal humerus; elbow; fracture fixation; humeral fracture; osteosynthesis; INTERNAL-FIXATION; OPEN REDUCTION; CAPITELLUM;
D O I
10.1016/j.jse.2024.05.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Coronal shear fractures of the capitellum are rare injuries which can be challenging to treat. The aim of this study was to compare the biomechanical properties of different internal screw fixation techniques for Dubberley type IA fractures of the capitellum. Methods: In this biomechanical study, Dubberley type IA fractures of the capitellum were created in 30 human fresh-frozen humeri. The specimens were then divided into 3 groups: fixation was either performed with 3 x 3.0 mm headless cannulated compression screws (HCCSs) in anteroposterior (AP) orientation (AP group), 3 x 3.0 mm HCCSs in posteroanterior (PA) orientation (PA group) or with 2 x 3.0 mm HCCSs in PA orientation and 1 x 3.0 mm HCCS in lateral orientation (LAT) group. Displacement under cyclic loading and ultimate load-to-failure were evaluated in all specimens. Results: There was no significant difference in fragment displacement after 2000 cycles between AP and PA groups (0.8 +/- 0.5 mm vs. 0.8 +/- 0.6 mm; P = .987) or PA and LAT groups (0.8 +/- 0.6 mm vs. 0.8 +/- 0.3 mm; P = .966). LAT group showed the highest load-to- failure (548 +/- 250 N) without reaching statistically significant difference to AP group (388 +/- 173 N; P = .101). There was also no significant difference between AP and PA groups (388 +/- 173 N vs. 422 +/- 114 N; P = .649). Conclusions: Variations in screw placement had no statistically significant influence on cyclic displacement or load-to-failure in Dubberley Type IA fractures. However, fracture fixation in 2 planes-both the coronal and the sagittal plane-by adding a screw in a lateral to medial direction may be beneficial to increase primary stability.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] Optimal Screw Orientation for Fixation of Coronoid Fractures
    Moon, Jun-Gyu
    Zobitz, Mark E.
    An, Kai-Nan
    O'Driscoll, Shawn W.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (04) : 277 - 280
  • [2] Screw fixation of radial head fractures: Compression screw versus lag screw-A biomechanical comparison
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Appelmann, Philipp
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1015 - 1019
  • [3] Comparison of lateral approach versus anterolateral approach with Herbert screw fixation for isolated coronal shear fractures of humeral capitellum
    Yu, Tengbo
    Tao, Hao
    Xu, Fenglei
    Hu, Yanling
    Zhang, Chengdong
    Zhou, Guangjie
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [4] Comparison of lateral approach versus anterolateral approach with Herbert screw fixation for isolated coronal shear fractures of humeral capitellum
    Tengbo Yu
    Hao Tao
    Fenglei Xu
    Yanling Hu
    Chengdong Zhang
    Guangjie Zhou
    Journal of Orthopaedic Surgery and Research, 14
  • [5] EXPERIMENTAL SPIRAL FRACTURES - AN INVITRO BIOMECHANICAL COMPARISON OF LAG-SCREW FIXATION TO PLATE FIXATION
    COX, LG
    DAHNERS, LE
    GILBERT, JA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (243) : 189 - 194
  • [6] Effect of different orientations of screw fixation for radial head fractures: a biomechanical comparison
    Shi, Xuchao
    Pan, Tianlong
    Wu, Dengying
    Cai, Ningyu
    Chen, Rong
    Li, Bin
    Zhang, Rui
    Zhou, Chengwei
    Pan, Jun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [7] Suture versus screw fixation of displaced tibial eminence fractures: A biomechanical comparison
    Bong, MR
    Romero, A
    Kubiak, E
    Iesaka, K
    Heywood, CS
    Kummer, F
    Rosen, J
    Jazrawi, L
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (10): : 1172 - 1176
  • [8] Effect of different orientations of screw fixation for radial head fractures: a biomechanical comparison
    Xuchao Shi
    Tianlong Pan
    Dengying Wu
    Ningyu Cai
    Rong Chen
    Bin Li
    Rui Zhang
    Chengwei Zhou
    Jun Pan
    Journal of Orthopaedic Surgery and Research, 12
  • [9] Screw fixation of scaphoid fractures: A biomechanical assessment of screw length and screw augmentation
    Dodds, SD
    Panjabi, MM
    Slade, JF
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (03): : 405 - 413
  • [10] Biomechanical comparison of screw osteosyntheses and anatomical plating for coronoid shear fractures of the ulna
    Rausch, Valentin
    Jettkant, Birger
    Lotzien, Sebastian
    Rosteius, Thomas
    Mempel, Eileen
    Schildhauer, Thomas A.
    Seybold, Dominik
    Gessmann, Jan
    Koenigshausen, Matthias
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (09) : 1509 - 1515