Biomechanical analysis of step-up and step-down tasks in knee osteoarthritis: Insights from leading and trailing limbs

被引:1
|
作者
Roberts, Oliver [1 ]
Wu, Tsung-Lin [1 ]
Teng, Phillis [2 ]
Lau, Jun Liang [3 ]
Pua, Yong Hao [4 ]
Clark, Ross A. [5 ]
Hu, Yi [6 ]
Tan, Bryan Yijia [1 ,7 ]
机构
[1] Nanyang Technol Univ, Rehabil Res Inst Singapore, 11 Mandalay Rd, 14-03 Clin Sci Bldg, Singapore 308232, Singapore
[2] Nanyang Technol Univ, Natl Inst Educ, Phys Educ & Sports Sci Acad Grp, 1 Nanyang Walk, Singapore 637616, Singapore
[3] Singapore Gen Hosp, Orthopaed Dept, 20 Coll Rd, Singapore 169856, Singapore
[4] Singapore Gen Hosp, Dept Physiotherapy, Outram Rd, Singapore 169608, Singapore
[5] Univ Sunshine Coast, Sch Hlth & Sports Sci, 90 Sippy Downs Dr, Sippy Downs, Qld 4556, Australia
[6] Nanyang Technol Univ, Lee Kong Chian Sch Med, 11 Mandalay Rd,17-01, Singapore 308232, Singapore
[7] Woodlands Hlth, Natl Healthcare Grp, Dept Orthopaed Surg, Singapore 737628, Singapore
关键词
Knee osteoarthritis; Motion analysis; Biomechanics; Step-up; Step-down; Statistical parametric mapping; JOINT COORDINATE SYSTEM; STANDING BALANCE; STAIR DESCENT; GLOBAL BURDEN; DEFINITION; DISEASE; HIP; RELIABILITY; ADAPTATIONS; INDIVIDUALS;
D O I
10.1016/j.clinbiomech.2025.106436
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Stair climbing tests are pivotal when assessing physical performance in knee osteoarthritis patients, yet the biomechanical strategies that underpin poor stair climbing ability are heterogeneously reported. Single step tasks emulate a step-by-step gait pattern, an approach associated with knee pain when stair climbing. The objective of this study is to analyse the biomechanics and electromyography activity of both the leading and trailing limbs during single Step-up and Down tasks in knee osteoarthritis patients. Methods: Three-dimensional motion analysis captured biomechanical data of twenty participants with knee osteoarthritis (n = 20) and twenty four (n = 24) age matched controls completing isolated Step-Up and Step-Down tasks. Data was collected from both the leading and trailing limbs and analysed continuously using One-dimensional Statistical Parametric Mapping (alpha = 0.05). Findings: During Step-Up, knee osteoarthritis participants demonstrated kinematic (p < 0.001), kinetic (p = 0.045), and electromyography (p < 0.001) variance compared to control participants, whilst Step-Down induced elevated external knee adduction moments (p = 0.042). Across both tasks, knee osteoarthritis participants stood with increased lower limb flexion in quiet standing and spent a proportionally elevated time in transitional double stance during Step-Up (p = 0.02). Interpretation: Our study reveals that knee osteoarthritis patients display distinctive biomechanical strategies during single Step-Up and Down tasks, that deviate depending on whether the osteoarthritic knee is leading or trailing. Single-step tasks are a safer and practical alternative to other stair climbing tests. We hope that clinicians can use these findings to guide treatments that promote less effortful step and stair ambulation in knee osteoarthritis patients with advanced disease.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of tumour blood flow changes induced by step-up and step-down heating
    Kozin, SV
    Borisov, MB
    Hasegawa, T
    HaKawa, SK
    Tanaka, Y
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1996, 12 (01) : 139 - 146
  • [42] Branding the hotel industry: The effect of step-up versus step-down brand extensions
    Hultman, Magnus
    Papadopoulou, Christina
    Oghazi, Pejvak
    Opoku, Robert
    JOURNAL OF BUSINESS RESEARCH, 2021, 124 : 560 - 570
  • [43] A STEP-UP AND STEP-DOWN DC VOLTAGE CONVERTER WITH THYRISTOR TIME RATIO CONTROL
    SATO, N
    MURASE, K
    ELECTRICAL ENGINEERING IN JAPAN, 1969, 89 (11) : 43 - +
  • [44] OBSERVATIONAL USTEKINUMAB DOSING PARADIGM IN PSORIASIS: EVIDENCE OF STEP-UP AND STEP-DOWN EVENTS
    Carter, C.
    Cao, Z.
    Wilson, K.
    Schenkel, B.
    VALUE IN HEALTH, 2013, 16 (03) : A179 - A179
  • [45] Anisotropic diffusion between the step-up and the step-down directions on a Si(001) surface
    Doi, T
    Ichikawa, M
    Hosoki, S
    Ninomiya, K
    PHYSICAL REVIEW B, 1996, 53 (24): : 16609 - 16614
  • [46] THE RELATIONSHIP BETWEEN STEP-UP AND STEP-DOWN PHOTOPHOBIC RESPONSES IN EUGLENA-GRACILIS
    KUZNICKI, L
    WALNE, PL
    ACTA PROTOZOOLOGICA, 1989, 28 (3-4) : 215 - 229
  • [47] STEP-DOWN AND STEP-UP LIGHTING PROGRAM ON THE LAYING PERFORMANCE OF WHITE LEGHORN FOWLS
    THYAGARAJAN, D
    KOTHANDARAMAN, P
    RAMAKRISHNA, J
    SUNDARARASU, V
    NARAHARI, D
    KALATHARAN, J
    INDIAN JOURNAL OF ANIMAL SCIENCES, 1989, 59 (04): : 479 - 481
  • [48] Effects of the step-up/step-down and step-down milk feeding procedures on the performance, structural growth, and blood metabolites of Holstein dairy calves
    Omidi-Mirzaei, H.
    Khorvash, M.
    Ghorbani, G. R.
    Moshiri, B.
    Mirzaei, M.
    Pezeshki, A.
    Ghaffari, M. H.
    JOURNAL OF DAIRY SCIENCE, 2015, 98 (11) : 7975 - 7981
  • [49] Analysis of new step-up and step-down 18-pulse direct asymmetric autotransformer-rectifiers
    Burgos, RP
    Uan-Zo-Li, A
    Lacaux, F
    Roshan, A
    Wang, F
    Boroyevich, D
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 145 - 152
  • [50] A Novel Method for Smooth Transition in Step-Up/Step-Down DC-DC Converter
    Ma, Yanzhao
    Wang, Hongyi
    Chen, Guican
    Qu, Fan
    2009 IEEE INTERNATIONAL CONFERENCE OF ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC 2009), 2009, : 95 - 98