Biomechanical analysis of step-up and step-down tasks in knee osteoarthritis: Insights from leading and trailing limbs

被引:1
|
作者
Roberts, Oliver [1 ]
Wu, Tsung-Lin [1 ]
Teng, Phillis [2 ]
Lau, Jun Liang [3 ]
Pua, Yong Hao [4 ]
Clark, Ross A. [5 ]
Hu, Yi [6 ]
Tan, Bryan Yijia [1 ,7 ]
机构
[1] Nanyang Technol Univ, Rehabil Res Inst Singapore, 11 Mandalay Rd, 14-03 Clin Sci Bldg, Singapore 308232, Singapore
[2] Nanyang Technol Univ, Natl Inst Educ, Phys Educ & Sports Sci Acad Grp, 1 Nanyang Walk, Singapore 637616, Singapore
[3] Singapore Gen Hosp, Orthopaed Dept, 20 Coll Rd, Singapore 169856, Singapore
[4] Singapore Gen Hosp, Dept Physiotherapy, Outram Rd, Singapore 169608, Singapore
[5] Univ Sunshine Coast, Sch Hlth & Sports Sci, 90 Sippy Downs Dr, Sippy Downs, Qld 4556, Australia
[6] Nanyang Technol Univ, Lee Kong Chian Sch Med, 11 Mandalay Rd,17-01, Singapore 308232, Singapore
[7] Woodlands Hlth, Natl Healthcare Grp, Dept Orthopaed Surg, Singapore 737628, Singapore
关键词
Knee osteoarthritis; Motion analysis; Biomechanics; Step-up; Step-down; Statistical parametric mapping; JOINT COORDINATE SYSTEM; STANDING BALANCE; STAIR DESCENT; GLOBAL BURDEN; DEFINITION; DISEASE; HIP; RELIABILITY; ADAPTATIONS; INDIVIDUALS;
D O I
10.1016/j.clinbiomech.2025.106436
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Stair climbing tests are pivotal when assessing physical performance in knee osteoarthritis patients, yet the biomechanical strategies that underpin poor stair climbing ability are heterogeneously reported. Single step tasks emulate a step-by-step gait pattern, an approach associated with knee pain when stair climbing. The objective of this study is to analyse the biomechanics and electromyography activity of both the leading and trailing limbs during single Step-up and Down tasks in knee osteoarthritis patients. Methods: Three-dimensional motion analysis captured biomechanical data of twenty participants with knee osteoarthritis (n = 20) and twenty four (n = 24) age matched controls completing isolated Step-Up and Step-Down tasks. Data was collected from both the leading and trailing limbs and analysed continuously using One-dimensional Statistical Parametric Mapping (alpha = 0.05). Findings: During Step-Up, knee osteoarthritis participants demonstrated kinematic (p < 0.001), kinetic (p = 0.045), and electromyography (p < 0.001) variance compared to control participants, whilst Step-Down induced elevated external knee adduction moments (p = 0.042). Across both tasks, knee osteoarthritis participants stood with increased lower limb flexion in quiet standing and spent a proportionally elevated time in transitional double stance during Step-Up (p = 0.02). Interpretation: Our study reveals that knee osteoarthritis patients display distinctive biomechanical strategies during single Step-Up and Down tasks, that deviate depending on whether the osteoarthritic knee is leading or trailing. Single-step tasks are a safer and practical alternative to other stair climbing tests. We hope that clinicians can use these findings to guide treatments that promote less effortful step and stair ambulation in knee osteoarthritis patients with advanced disease.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] An interleaved step-up/step-down converter for fuel cell vehicle applications
    Gao, Dawei
    Jin, Zhenhua
    Liu, Jiexun
    Ouyang, Minggao
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (47) : 22422 - 22432
  • [22] Principles of antibiotic application in children with lobar pneumonia: Step-up or step-down
    Li, Yan
    Han, Feng
    Yang, Yan
    Chu, Jianwei
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 13 (06) : 2681 - 2684
  • [23] Step-up and step-down methods for testing multiple hypotheses in sequential experiments
    De, Shyamal K.
    Baron, Michael
    JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2012, 142 (07) : 2059 - 2070
  • [24] Effects of step-down and step-up heating combined with radiation in vivo system
    Hiraoka, M.
    Abe, M.
    Jo, S.
    Takahashi, M.
    Miyakoshi, J.
    Heki, S.
    Proceedings of the International Congress of Radiation Research, 1984, : 6 - 20
  • [25] Step-up and Step-down Asymmetrical 24-Pulse Autotransformer Rectifier
    Zhang, Lu
    Ge, Hong-juan
    Jiang, Fan
    Yang, Guang
    Lin, Yi
    JOURNAL OF POWER ELECTRONICS, 2018, 18 (05) : 1536 - 1544
  • [26] COMPUTATIONALLY EFFICIENT STEP-UP AND STEP-DOWN PROCEDURES FOR REAL PREDICTOR COEFFICIENTS
    KRISHNA, H
    MORGERA, SD
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1988, 36 (08): : 1353 - 1355
  • [27] American step-up and step-down default swaps under Levy models
    Leung, Tim
    Yamazaki, Kazutoshi
    QUANTITATIVE FINANCE, 2013, 13 (01) : 137 - 157
  • [28] High step-up high step-down bidirectional DC/DC converter
    Babaei, Ebrahim
    Saadatizadeh, Zahra
    Cecati, Carlo
    IET POWER ELECTRONICS, 2017, 10 (12) : 1556 - 1571
  • [29] Two Switches Common Grounded Transformerless Step-Up and Step-Down Inverter
    dos Santos, Ion Leandro
    Lazzarin, Telles Brunelli
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 600 - 605
  • [30] Step-up and step-down approaches to treatment of gastroesophageal reflux disease in children
    Hassall E.
    Current Gastroenterology Reports, 2008, 10 (3) : 324 - 331