Biomechanical analysis of step-up and step-down tasks in knee osteoarthritis: Insights from leading and trailing limbs

被引:1
|
作者
Roberts, Oliver [1 ]
Wu, Tsung-Lin [1 ]
Teng, Phillis [2 ]
Lau, Jun Liang [3 ]
Pua, Yong Hao [4 ]
Clark, Ross A. [5 ]
Hu, Yi [6 ]
Tan, Bryan Yijia [1 ,7 ]
机构
[1] Nanyang Technol Univ, Rehabil Res Inst Singapore, 11 Mandalay Rd, 14-03 Clin Sci Bldg, Singapore 308232, Singapore
[2] Nanyang Technol Univ, Natl Inst Educ, Phys Educ & Sports Sci Acad Grp, 1 Nanyang Walk, Singapore 637616, Singapore
[3] Singapore Gen Hosp, Orthopaed Dept, 20 Coll Rd, Singapore 169856, Singapore
[4] Singapore Gen Hosp, Dept Physiotherapy, Outram Rd, Singapore 169608, Singapore
[5] Univ Sunshine Coast, Sch Hlth & Sports Sci, 90 Sippy Downs Dr, Sippy Downs, Qld 4556, Australia
[6] Nanyang Technol Univ, Lee Kong Chian Sch Med, 11 Mandalay Rd,17-01, Singapore 308232, Singapore
[7] Woodlands Hlth, Natl Healthcare Grp, Dept Orthopaed Surg, Singapore 737628, Singapore
关键词
Knee osteoarthritis; Motion analysis; Biomechanics; Step-up; Step-down; Statistical parametric mapping; JOINT COORDINATE SYSTEM; STANDING BALANCE; STAIR DESCENT; GLOBAL BURDEN; DEFINITION; DISEASE; HIP; RELIABILITY; ADAPTATIONS; INDIVIDUALS;
D O I
10.1016/j.clinbiomech.2025.106436
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Stair climbing tests are pivotal when assessing physical performance in knee osteoarthritis patients, yet the biomechanical strategies that underpin poor stair climbing ability are heterogeneously reported. Single step tasks emulate a step-by-step gait pattern, an approach associated with knee pain when stair climbing. The objective of this study is to analyse the biomechanics and electromyography activity of both the leading and trailing limbs during single Step-up and Down tasks in knee osteoarthritis patients. Methods: Three-dimensional motion analysis captured biomechanical data of twenty participants with knee osteoarthritis (n = 20) and twenty four (n = 24) age matched controls completing isolated Step-Up and Step-Down tasks. Data was collected from both the leading and trailing limbs and analysed continuously using One-dimensional Statistical Parametric Mapping (alpha = 0.05). Findings: During Step-Up, knee osteoarthritis participants demonstrated kinematic (p < 0.001), kinetic (p = 0.045), and electromyography (p < 0.001) variance compared to control participants, whilst Step-Down induced elevated external knee adduction moments (p = 0.042). Across both tasks, knee osteoarthritis participants stood with increased lower limb flexion in quiet standing and spent a proportionally elevated time in transitional double stance during Step-Up (p = 0.02). Interpretation: Our study reveals that knee osteoarthritis patients display distinctive biomechanical strategies during single Step-Up and Down tasks, that deviate depending on whether the osteoarthritic knee is leading or trailing. Single-step tasks are a safer and practical alternative to other stair climbing tests. We hope that clinicians can use these findings to guide treatments that promote less effortful step and stair ambulation in knee osteoarthritis patients with advanced disease.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Step-up and step-down treatments for optimal asthma control in children and adolescents
    Bernstein, Jonathan A.
    Mansfield, Lyndon
    JOURNAL OF ASTHMA, 2019, 56 (07) : 758 - 770
  • [32] Step-up and step-down procedures controlling the number and proportion of false positives
    Somerville, Paul N.
    Hemmelmann, Claudia
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2008, 52 (03) : 1323 - 1334
  • [33] Step-Up and Step-Down Converter Integrated With Motor Inverter for Powertrain Applications
    Ruiz Erni, Ivan
    Vidal-Idiarte, Enric
    Calvente, Javier
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2022, 10 (01) : 285 - 296
  • [34] Analysis and Control Design of a Step-Up/Step-Down Converter for Battery-Discharge Voltage Regulation
    Villanueva-Loredo, Juan A.
    Martinez-Rodriguez, Panfilo R.
    Rodriguez-Cortes, Christopher J.
    Langarica-Cordoba, Diego
    Hernandez-Gomez, Angel
    Guilbert, Damien
    ELECTRONICS, 2025, 14 (05):
  • [35] Step-Up/Step-Down Switched Capacitor Direct AC-AC Converter
    de Souza, Alencar Franco
    Tofoli, Fernando Lessa
    Ribeiro, Enio Roberto
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (05) : 4427 - 4436
  • [36] Asymptotic comparison of the critical values of step-down and step-up multiple comparison procedures
    Finner, H
    Roters, M
    JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 1999, 79 (01) : 11 - 30
  • [37] CONTROL-ORIENTED MODELS OF STEP-UP AND STEP-DOWN PHOTOVOLTAIC POWER SYSTEMS
    Velasquez-Vasquez, Juan C.
    Yarce-De los Rios, Sara
    Ramos-Paja, Carlos Andres
    Arango Zuluaga, Eliana Isabel
    Gonzalez, Daniel
    DYNA-COLOMBIA, 2012, 79 (172): : 67 - 76
  • [38] Hochbergs step-up method: Cutting corners off holms step-down method
    Huang, Yifan
    Hsu, Jason C.
    BIOMETRIKA, 2007, 94 (04) : 965 - 975
  • [39] Step-up/step-down converter takes 2 to 16V inputs
    Bordogna, L
    Vasalli, L
    EDN, 1998, 43 (15) : 99 - 99
  • [40] Step-Up and Step-Down Treatment Approaches for COPD: A Holistic View of Progressive Therapies
    Lopez-Campos, Jose Luis
    Hernandez, Laura Carrasco
    Ruiz-Duque, Borja
    Reinoso-Arija, Rocio
    Caballero-Eraso, Candelaria
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2021, 16 : 2065 - 2076