摘要
Background & objectives: Timely detection of population with beta-thalassemia trait (BTT) followed by genetic counselling is an advocated method of preventing the birth of a child with beta-thalassemia major. In this study we aim to assess the diagnostic accuracy of Gazelle, a point-of-care (POC) testing device, in screening for BTT in hospital laboratory setting. Methods: Standards for Reporting Diagnostic Accuracy (STARD) guidelines were followed in developing study design, recruiting study participants and sample size calculation for the current research. A consecutive sample of 446 participants was recruited for this study and was tested for the reference test Gazelle as well as the gold standard cation exchange high performance liquid chromatography (CE-HPLC). Low serum ferritin levels are known to interfere with the production of HbA2 and in turn lead to false negative results. Hence, the study population was divided into two categories with respect to a cut off value of 15ng/dl of serum ferritin and the results were analyzed. Results: Overall diagnostic accuracy of Gazelle for detecting BTT was found to be 95.3 per cent with a confidence interval (CI) of (92.9 - 97.1) and the sensitivity was 94.5 per cent with a 95% CI of (84.8 - 98.8). When analyzed by the serum ferritin level the diagnostic accuracy was found to be 94.7 per cent (91.1% - 97.1%) and 95.7 per cent (91.8% - 98.1%) for participants with serum ferritin level as > 15 ng/ml and < 15 ng/ml, respectively. Interpretation & conclusions: This study found Gazelle to be a good screening tool for beta-thalassemia trait with high sensitivity, specificity and accuracy. However, it is recommended that the final confirmation of the diagnosis done by a diagnostic test like HPLC or Capillary Zone Electrophoresis (CZE).
引用
收藏
页码:194 / 200
页数:7
相关论文
共 50 条
  • [1] Assessment accuracy of the Afinion point-of-care device compared with central laboratory testing
    Zhou, Hui
    Li, Pengqiu
    Zhang, Xuejun
    Xian, Yang
    Wu, Jichuan
    Bao, Mingjing
    Yang, Yan
    Zhang, Lei
    Zhu, Xianjun
    Cao, Xu
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2015, 31 : 49 - 50
  • [2] Point-of-Care Testing on a Mobile Medical Unit in Northern Thailand: Screening for Hyperglycemia, Hyperlipidemia, and Thalassemia Trait
    Boonlert, Wanvisa
    Kost, Gerald J.
    Jiraviriyakul, Arunya
    Tangvarasittichai, Surapon
    POINT OF CARE, 2006, 5 (04): : 164 - 167
  • [3] EVALUATION OF A POINT-OF-CARE SCREENING DEVICE "GAZELLE" FOR CHILDREN WITH SICKLE CELL DISEASE IN GHANA
    Segbefia, Catherine
    Dei-Adomakoh, Yvonne
    Mensah, Enoch
    Rocheleau, Anne
    Thota, Priyaleela
    Odame, Isaac
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2021, 105 (05): : 21 - 21
  • [4] VALIDATION STUDY OF A NEW POINT-OF-CARE HEMOZOIN BASED MALARIA DIAGNOSTIC DEVICE GAZELLE™ IN INDIA
    Verma, Anil Kumar
    Thota, Priyaleela
    Patel, Madhav
    Shah, Digvijay
    Srivas, Shweta
    Bharti, Praveen K.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2021, 105 (05): : 200 - 201
  • [5] Accuracy of a point-of-care testing device in children with suspected respiratory allergy
    Sarratud, Teresita
    Donnanno, Simona
    Terracciano, Luigi
    Trimarco, Gemma
    Martelli, Alberto
    Petersson, Carl Johan
    Borres, Magnus P.
    Fiocchi, Alessandro
    Cavagni, Giovanni
    ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (02) : E11 - E17
  • [6] Diagnostic accuracy of a new point-of-care screening assay for celiac disease
    Benkebil, Faiza
    Combescure, Christophe
    Anghel, Silvia I.
    Duvanel, Cecile Besson
    Schaeppi, Michela G.
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (31) : 5111 - 5117
  • [7] Diagnostic accuracy of a new point-of-care screening assay for celiac disease
    Faiza Benkebil
    Christophe Combescure
    Silvia I Anghel
    Cécile Besson Duvanel
    Michela G Schppi
    World Journal of Gastroenterology, 2013, (31) : 5111 - 5117
  • [8] Point-of-Care Diagnostic Testing Markets
    Dooley, Joseph F.
    POINT OF CARE, 2009, 8 (04): : 154 - 156
  • [9] Accuracy evaluation of a point-of-care testing device for lipid levels in a primary care context
    Yu, S.
    Song, S. A.
    Jun, K. R.
    Lee, J. N.
    CLINICA CHIMICA ACTA, 2024, 558
  • [10] Point-of-Care Diagnostic Test for Beta-Thalassemia
    An, Ran
    Avanaki, Alireza
    Thota, Priyaleela
    Nemade, Sai
    Mehta, Amrish
    Gurkan, Umut A.
    BIOSENSORS-BASEL, 2024, 14 (02):