Point-of-Care Diagnostic Test for Beta-Thalassemia

被引:3
|
作者
An, Ran [1 ,2 ,3 ]
Avanaki, Alireza [4 ]
Thota, Priyaleela [4 ]
Nemade, Sai [5 ,6 ]
Mehta, Amrish [5 ,6 ]
Gurkan, Umut A. [1 ,7 ,8 ]
机构
[1] Case Western Reserve Univ, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
[2] Univ Houston, Dept Biomed Engn, Houston, TX 77004 USA
[3] Univ Houston, Dept Biomed Sci, Houston, TX 77004 USA
[4] HemexHealth Inc, Portland, OR 97239 USA
[5] Plasma Lab, Jalgaon 425001, India
[6] Apple Diagnost Lab, Mumbai 400077, India
[7] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[8] Case Western Reserve Univ, Case Comprehens Canc Ctr, Cleveland, OH 44106 USA
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 02期
关键词
hemoglobin variants; hemoglobin disorders; beta-thalassemia; anemia; point-of-care screening; microchip electrophoresis; SICKLE-CELL-DISEASE;
D O I
10.3390/bios14020083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hemoglobin (Hb) disorders are among the most common monogenic diseases affecting nearly 7% of the world population. Among various Hb disorders, approximately 1.5% of the world population carries beta-thalassemia (beta-Thal), affecting 40,000 newborns every year. Early screening and a timely diagnosis are essential for beta-thalassemia patients for the prevention and management of later clinical complications. However, in Africa, Southern Europe, the Middle East, and Southeast Asia, where beta-thalassemia is most prevalent, the diagnosis and screening for beta-thalassemia are still challenging due to the cost and logistical burden of laboratory diagnostic tests. Here, we present Gazelle, which is a paper-based microchip electrophoresis platform that enables the first point-of-care diagnostic test for beta-thalassemia. We evaluated the accuracy of Gazelle for the beta-Thal screening across 372 subjects in the age range of 4-63 years at Apple Diagnostics lab in Mumbai, India. Additionally, 30 blood samples were prepared to mimic beta-Thal intermediate and beta-Thal major samples. Gazelle-detected levels of Hb A, Hb F, and Hb A2 demonstrated high levels of correlation with the results reported through laboratory gold standard high-performance liquid chromatography (HPLC), yielding a Pearson correlation coefficient = 0.99. This ability to obtain rapid and accurate results suggests that Gazelle may be suitable for the large-scale screening and diagnosis of beta-Thal.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Paper-Based Microchip Electrophoresis Enabled First Point-of-Care Diagnostic Test for Beta-Thalassemia
    An, Ran
    Avanaki, Alireza
    Thota, Priyaleela
    Nemade, Sai
    Mehta, Amrish
    Gurkan, Umut A.
    BLOOD, 2022, 140 : 7822 - 7823
  • [2] Incidental Diagnosis of Adult Beta-Thalassemia With Point-of-Care Ultrasound in the Emergency Department: A Case Report
    Dennis, Jasmine L.
    Morrow, Dustin
    Cupp, Julia A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (12)
  • [3] LIBS as a diagnostic tool in pediatrics beta-thalassemia
    Rujittika Mungmunpuntipantip
    Viroj Wiwanitkit
    Lasers in Medical Science, 2022, 37 : 1371 - 1371
  • [4] LIBS as a diagnostic tool in pediatrics beta-thalassemia
    Mungmunpuntipantip, Rujittika
    Wiwanitkit, Viroj
    LASERS IN MEDICAL SCIENCE, 2022, 37 (02) : 1371 - 1371
  • [5] NEW CHROMOSOME TEST TO SCREEN FOR BETA-THALASSEMIA
    WINGERSON, L
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 250 (24): : 3271 - 3272
  • [6] BETA-THALASSEMIA
    BANARJEE, TK
    WILSON, SGF
    EUROPEAN JOURNAL OF PEDIATRICS, 1987, 146 (05) : 539 - 539
  • [7] BETA-THALASSEMIA
    KLEIHAUER, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1983, 108 (25) : 998 - 998
  • [8] BETA-THALASSEMIA
    THEIN, SL
    BAILLIERES CLINICAL HAEMATOLOGY, 1993, 6 (01): : 151 - 175
  • [9] BETA-THALASSEMIA
    KLEIHAUER, E
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1985, 110 (01) : 36 - 36
  • [10] Beta-thalassemia
    Renzo Galanello
    Raffaella Origa
    Orphanet Journal of Rare Diseases, 5