Diagnostic accuracy of a new point-of-care screening assay for celiac disease

被引:33
|
作者
Benkebil, Faiza [1 ]
Combescure, Christophe [2 ,3 ]
Anghel, Silvia I. [4 ]
Duvanel, Cecile Besson [5 ]
Schaeppi, Michela G. [6 ]
机构
[1] Vidymed, CH-1007 Lausanne, Switzerland
[2] Univ Geneva, Dept Hlth & Community Med, Div Clin Epidemiol, CH-1007 Geneva, Switzerland
[3] Univ Hosp Geneva, CH-1007 Geneva, Switzerland
[4] BioArk, R&D Dept, Augurix, CH-1870 Monthey, Switzerland
[5] BioArk, Augurix, CH-1870 Monthey, Switzerland
[6] Univ Hosp Geneva, Dept Pediat, Pediat Gastroenterol Unit, CH-1211 Geneva, Switzerland
关键词
Celiac disease; Deamidated gliadin; Total immunoglobulin A; Screening; Point-of-care assay; DEAMIDATED GLIADIN PEPTIDES; TISSUE TRANSGLUTAMINASE; EARLY-CHILDHOOD; ANTIBODIES; ANTIGLIADIN; ENDOMYSIUM; PREVALENCE; PREDICTORS; TESTS;
D O I
10.3748/wjg.v19.i31.5111
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To determine the diagnostic accuracy of a new point-of-care assay detecting anti-deamidated gliadin peptides in celiac disease (CD) patients. METHODS: One-hundred-and-twelve patients (age range: 1.8-79.2 years old) with clinical symptoms suggestive of CD and/or first-degree relatives (FDR) of CD patients (n = 66), and confirmed CD on a gluten-free diet (GFD) (n = 46), were prospectively enrolled in the study at Gastroenterology outpatient clinics for adult patients and from the Gastroenterology Consultation Ward at the Pediatric Department of the University Hospital of Geneva. Written informed consent was obtained from all subjects enrolled. The study received approval from the local ethics committee. The original CD diagnosis had been based on serum-positive IgA anti-tissue transglutaminase enzyme-linked immunosorbent assay (ELISA) (QuantaLite T, Inova Diagnostics, San Diego, CA, United States) and on biopsy results. Serum samples from all study participants were tested by the new CD lateral flow immunochromatographic assay (CD-LFIA) device, Simtomax (R) Blood Drop (Augurix SA, BioArk, Monthey, Switzerland) to detect immunoglobulin (Ig) A and IgG antibodies against de-amidated gliadin peptides. The diagnostic performance was evaluated using receiver operating characteristic curves with 95% CIs. A cut-off of 2 on the Rann colorimetric scale was used to calculate the device's sensitivity and specificity. RESULTS: CD-LFIA was highly accurate in detecting untreated celiac patients. In the group of patients with CD symptoms and/or FDR, eight new cases of CD were detected by ELISA and biopsy. All of these new cases were also correctly identified by CD-LFIA. The test yielded four false positive and four false negative results. The false positive results were all within the groups with clinical symptoms suggestive of CD and/or FDR, whereas the false negative results were all within the GFD group. The test yeld a sensitivity of 78.9% (95% CI: 54.4-93.9) and specificity of 95.7% (95% CI: 89.4-98.8), and the area under the curve reached 0.893 (95% CI: 0.798-0.988). The Kappa coefficient, calculated according to the values obtained by two readers from the same device, was of 0.96 (SE: 0.06). When the GFD patients were excluded from the analysis, the area under the curve reached 0.989 (95% CI: 0.971-1.000) and the Kappa coefficient, calculated according to the values obtained by two readers from the same device, became 0.96 (SE: 0.07). Furthermore, using the Rann scale cut-off of 2 without the GFD pa- tients, sensitivity was 100% and specificity was 93.1% (95% CI: 83.3-98.1). CONCLUSION: The new CD-LFIA rapid screening test shows good diagnostic accuracy, sensitivity and specificity, and may rule out CD in patients with CD-related symptoms. (C) 2013 Baishideng. All rights reserved.
引用
收藏
页码:5111 / 5117
页数:7
相关论文
共 50 条
  • [1] Diagnostic accuracy of a new point-of-care screening assay for celiac disease
    Faiza Benkebil
    Christophe Combescure
    Silvia I Anghel
    Cécile Besson Duvanel
    Michela G Schppi
    [J]. World Journal of Gastroenterology, 2013, (31) : 5111 - 5117
  • [2] Diagnostic Accuracy Among 4 Point-of-Care Tests for the Screening of HIV Infection
    Flores, Karina
    Leon, Segundo R.
    [J]. LABMEDICINE, 2013, 44 (02): : 172 - 175
  • [3] Diagnostic Accuracy of Point-of-Care Gastric Ultrasound
    Kruisselbrink, Richelle
    Gharapetian, Angineh
    Chaparro, Luis E.
    Ami, Noam
    Richler, Dustin
    Chan, Vincent W. S.
    Perlas, Anahi
    [J]. ANESTHESIA AND ANALGESIA, 2019, 128 (01): : 89 - 95
  • [4] Rapid Diagnostic for Point-of-Care Malaria Screening
    McBirney, Samantha E.
    Chen, Dongyu
    Scholtz, Alexis
    Ameri, Hossein
    Armani, Andrea M.
    [J]. ACS SENSORS, 2018, 3 (07): : 1264 - 1270
  • [5] Diagnostic Accuracy of Point-of-Care Tests for Detecting Albuminuria
    McTaggart, Malcolm P.
    Newall, Ronald G.
    Hirst, Jennifer A.
    Bankhead, Clare R.
    Lamb, Edmund J.
    Roberts, Nia W.
    Price, Christopher P.
    [J]. ANNALS OF INTERNAL MEDICINE, 2014, 160 (08) : 550 - +
  • [6] Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay
    Body, Richard
    Almashali, Malak
    Morris, Niall
    Moss, Phil
    Jarman, Heather
    Appelboam, Andrew
    Parris, Richard
    Chan, Louisa
    Walker, Alison
    Harrison, Mark
    Wootten, Andrea
    McDowell, Garry
    [J]. HEART, 2019, 105 (10) : 768 - +
  • [7] ADOPTABILITY AND ACCURACY OF POINT-OF-CARE ULTRASOUND IN SCREENING FOR VALVULAR HEART DISEASE IN THE PRIMARY CARE SETTING
    Lohese, Opema
    Garberich, Ross
    Stanberry, Larissa
    Sorajja, Paul
    Cavalcante, Joao
    Gossl, Mario
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1711 - 1711
  • [8] Adoptability and accuracy of point-of-care ultrasound in screening for valvular heart disease in the primary care setting
    Chugh, Yashasvi
    Lohese, Opema
    Sorajja, Paul
    Garberich, Ross
    Stanberry, Larissa
    Cavalcante, Joao
    Gossl, Mario
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (02) : 265 - 270
  • [9] Point-of-care diagnostic tests for tuberculosis disease
    Hong, Jia Mei
    Lee, Hyeyoung
    Menon, Nishanth, V
    Lim, Chwee Teck
    Lee, Luke P.
    Ong, Catherine W. M.
    [J]. SCIENCE TRANSLATIONAL MEDICINE, 2022, 14 (639)
  • [10] Can a point-of-care proteomic assay increase the accuracy of cystoscopy?
    Kelly, JD
    Westwood, ME
    Neal, DE
    [J]. NATURE CLINICAL PRACTICE UROLOGY, 2005, 2 (07): : 320 - 321