The effect of sampling window size on topographical maps of foveal cone density

被引:0
|
作者
Warr, Emma [1 ]
Grieshop, Jenna [1 ,2 ,3 ]
Cooper, Robert F. [1 ,2 ,3 ]
Carroll, Joseph [1 ,2 ,3 ,4 ]
机构
[1] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[2] Marquette Univ, Joint Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
来源
关键词
fovea; cone density; cone spacing; adaptive optics; retina; PHOTORECEPTOR PACKING DENSITY; VARIABILITY; ROD; ECCENTRICITY; FIXATION; METRICS; IMAGES;
D O I
10.3389/fopht.2024.1348950
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300 mu m) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56<mu>m(2) (compared to 844.10 mu m(2) for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Foveal cone mosaic and visual pigment density in dichromats
    Berendschot, TTJM
    vandeKraats, J
    vanNorren, D
    JOURNAL OF PHYSIOLOGY-LONDON, 1996, 492 (01): : 307 - 314
  • [12] Reproducibility in peak foveal cone density characterization in AOSLO images
    Wynne., Niamh
    Cava, Jenna
    Gaffney, Mina
    Heitkotter, Heather
    Schedit, Abigail
    Cooper, Robert F.
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [13] Reduced foveal cone density in early idiopathic macular telangiectasia
    Song, Hongxin
    Rossi, Ethan A.
    Williams, David R.
    BMJ OPEN OPHTHALMOLOGY, 2021, 6 (01):
  • [14] FOVEAL CONE OPTICAL-DENSITY IN RETINITIS-PIGMENTOSA
    ELSNER, AE
    BURNS, SA
    LOBES, LA
    APPLIED OPTICS, 1987, 26 (08): : 1378 - 1384
  • [15] Foveal cone spacing and cone photopigment density difference: Objective measurements in the same subjects
    Marcos, S
    Tornow, RP
    Elsner, AE
    Navarro, R
    VISION RESEARCH, 1997, 37 (14) : 1909 - 1915
  • [16] Effect of sampling array irregularity and window size on the discrimination of sampled gratings
    Evans, David W.
    Wang, Yizhong
    Haggerty, Kevin M.
    Thibos, Larry N.
    VISION RESEARCH, 2010, 50 (01) : 20 - 30
  • [17] Estimation of Fracture Size and Probability Density Function by Setting Scanlines in Rectangular Sampling Window
    Gu, Feifan
    Chen, Jianping
    Zhang, Qi
    Tan, Chun
    Zhang, Yansong
    Wang, Qing
    LITHOSPHERE, 2023, 2023 (01)
  • [18] FOVEAL CONE PIGMENT DENSITY DIFFERENCE AND REFLECTANCE IN RETINITIS-PIGMENTOSA
    KILBRIDE, PE
    FISHMAN, M
    FISHMAN, GA
    HUTMAN, LP
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (02) : 220 - 224
  • [19] In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
    Mirhajianmoghadam, Hanieh
    Jnawali, Ashutosh
    Musial, Gwen
    Queener, Hope M.
    Patel, Nimesh B.
    Ostrin, Lisa A.
    Porter, Jason
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [20] Senescence of foveal and parafoveal cone sensitivities and their relations to macular pigment density
    Werner, John S.
    Bieber, Michelle L.
    Schefrin, Brooke E.