Foveal cone spacing and cone photopigment density difference: Objective measurements in the same subjects

被引:26
|
作者
Marcos, S
Tornow, RP
Elsner, AE
Navarro, R
机构
[1] CSIC,INST OPT,E-28006 MADRID,SPAIN
[2] UNIV TUBINGEN,DEPT PATHOPHYSIOL VIS & NEUROOPHTHALMOL,D-72076 TUBINGEN,GERMANY
[3] HARVARD UNIV,BOSTON,MA 02114
关键词
cone photoreceptor; photopigment; physiological optics; retina; imaging;
D O I
10.1016/S0042-6989(96)00295-7
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Foveal cone spacing was measured in vivo using an objective technique: ocular speckle interferometry. Cone packing density was computed from cone spacing data. Foveal cone photopigment density difference was measured in the same subjects using retinal densitometry with a scanning laser ophthalmoscope. Both the cone packing density and cone photopigment density difference decreased sharply with increasing retinal eccentricity. From the comparison of both sets of measurements, the computed amounts of photopigment per cone increased slightly with increasing retinal eccentricity. Consistent with previous results, decreases in cone outer segment length are over-compensated by an increase in the outer segment area, at least in retinal eccentricities up to 1 deg. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1909 / 1915
页数:7
相关论文
共 50 条
  • [1] Kinetics of foveal cone photopigment in idiopathic epiretinal membrane
    Okamoto, Y
    Horio, N
    Terasaki, H
    Miyake, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S711 - S711
  • [2] FOVEAL CONE PHOTOPIGMENT BLEACHING IN CENTRAL SEROUS RETINOPATHY
    BURNS, SA
    ELSNER, AE
    LOBES, LA
    APPLIED OPTICS, 1988, 27 (06): : 1045 - 1049
  • [3] Mapping cone photopigment optical density
    Elsner, Ann E.
    Burns, Stephen A.
    Webb, Robert H.
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 1993, 10 (01): : 52 - 58
  • [4] CONE PHOTOPIGMENT DENSITY IN AGING AND AMD
    BURNS, SA
    ELSNER, AE
    WEITER, JJ
    KREITZ, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 690 - 690
  • [5] In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
    Mirhajianmoghadam, Hanieh
    Jnawali, Ashutosh
    Musial, Gwen
    Queener, Hope M.
    Patel, Nimesh B.
    Ostrin, Lisa A.
    Porter, Jason
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [6] In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
    Hanieh Mirhajianmoghadam
    Ashutosh Jnawali
    Gwen Musial
    Hope M. Queener
    Nimesh B. Patel
    Lisa A. Ostrin
    Jason Porter
    Scientific Reports, 10
  • [7] Kinetics of foveal cone photopigment in myopia without chorioretinal degeneration
    Horio, N
    Miyake, Y
    Horiguchi, M
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1999, 43 (01) : 44 - 47
  • [8] Repeatability of In Vivo Parafoveal Cone Density and Spacing Measurements
    Garrioch, Robert
    Langlo, Christopher
    Dubis, Adam M.
    Cooper, Robert F.
    Dubra, Alfredo
    Carroll, Joseph
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (05) : 632 - 643
  • [9] CONE PHOTOPIGMENT DENSITY AND FUNDUS APPEARANCE IN AMD
    BURNS, SA
    ELSNER, AE
    WEITER, JJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1161 - 1161
  • [10] MAPPING CONE PHOTOPIGMENT OPTICAL-DENSITY
    ELSNER, AE
    BURNS, SA
    WEBB, RH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (01): : 52 - 58