The effect of sampling window size on topographical maps of foveal cone density

被引:0
|
作者
Warr, Emma [1 ]
Grieshop, Jenna [1 ,2 ,3 ]
Cooper, Robert F. [1 ,2 ,3 ]
Carroll, Joseph [1 ,2 ,3 ,4 ]
机构
[1] Med Coll Wisconsin, Dept Ophthalmol & Visual Sci, Milwaukee, WI 53226 USA
[2] Marquette Univ, Joint Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Cell Biol Neurobiol & Anat, Milwaukee, WI 53226 USA
来源
关键词
fovea; cone density; cone spacing; adaptive optics; retina; PHOTORECEPTOR PACKING DENSITY; VARIABILITY; ROD; ECCENTRICITY; FIXATION; METRICS; IMAGES;
D O I
10.3389/fopht.2024.1348950
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300 mu m) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56<mu>m(2) (compared to 844.10 mu m(2) for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Modeling the Relationship Between Foveal Cone Density and Outer Segment Length
    Wilk, Melissa A.
    Cooper, Robert F.
    Wilk, Brandon M.
    Langlo, Christopher S.
    Carroll, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [22] Intersubject Variability of Foveal Cone Photoreceptor Density in Relation to Eye Length
    Li, Kaccie Y.
    Tiruveedhula, Pavan
    Roorda, Austin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6858 - 6867
  • [23] FOVEAL CONE PIGMENT DENSITY DIFFERENCE IN THE AGING HUMAN-EYE
    KILBRIDE, PE
    HUTMAN, LP
    FISHMAN, M
    READ, JS
    VISION RESEARCH, 1986, 26 (02) : 321 - 325
  • [24] In vivo assessment of foveal geometry and cone photoreceptor density and spacing in children
    Hanieh Mirhajianmoghadam
    Ashutosh Jnawali
    Gwen Musial
    Hope M. Queener
    Nimesh B. Patel
    Lisa A. Ostrin
    Jason Porter
    Scientific Reports, 10
  • [25] Foveal cone density shows a rapid postnatal maturation in the marmoset monkey
    Springer, Alan D.
    Troilo, David
    Possin, Daniel
    Hendrickson, Anita E.
    VISUAL NEUROSCIENCE, 2011, 28 (06) : 473 - 484
  • [26] Senescence of foveal and parafoveal cone sensitivities and their relations to macular pigment density
    Werner, JS
    Bieber, ML
    Schefrin, BE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (11) : 1918 - 1932
  • [27] EFFECT OF LIGHT ATTENUATION ON THE FOVEAL CONE ERG IN NORMAL SUBJECTS
    MILLER, S
    REMULLA, JFC
    SANDBERG, MA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2046 - 2046
  • [28] Evaluating outer segment length as a surrogate measure of peak foveal cone density
    Wilk, Melissa A.
    Wilk, Brandon M.
    Langlo, Christopher S.
    Cooper, Robert F.
    Carroll, Joseph
    VISION RESEARCH, 2017, 130 : 57 - 66
  • [29] EFFECT OF A BACKGROUND ON FOVEAL AND PARAFOVEAL CONE DARK-ADAPTATION
    KOOIJMAN, AC
    STENEKER, FWM
    SMEETS, JLRM
    VISION RESEARCH, 1978, 18 (10) : 1381 - 1385
  • [30] VISUAL-ACUITY AND FOVEAL CONE DENSITY IN THE RETINA OF THE AGED RHESUS-MONKEY
    ORDY, JM
    BRIZZEE, KR
    HANSCHE, J
    ANATOMICAL RECORD, 1981, 199 (03): : A188 - A188