Challenges of preanalytical variables in erythrocyte sedimentation rate: a CUBE 30 touch evaluation

被引:0
|
作者
Tomassetti, Flaminia [1 ,2 ]
Guerranti, Roberto [3 ]
Leoncini, Roberto [3 ]
Pieroni, Carolina [4 ]
Diamanti, Daniela [4 ]
Cirianni, Michele [3 ]
Silvestrini, Caterina [3 ]
Galasso, Lucrezia [3 ]
Pelagalli, Martina [1 ,2 ]
Nicolai, Eleonora [1 ]
Giovannelli, Alfredo [1 ,2 ]
Pieri, Massimo [1 ,2 ]
Bernardini, Sergio [1 ,2 ]
机构
[1] Univ Roma Tor Vergata, Dept Expt Med, via Montpellier 1, I-00133 Rome, Italy
[2] Tor Vergata Univ Hosp, Dept Lab Med, Rome, Italy
[3] Univ Hosp S Maria Alle Scotte Siena, Innovat Experimentat & Clin & Translat Res Dept, Clin Pathol Unit, Siena, Italy
[4] DIESSE Diagnost Senese SpA, Res & Dev Dept, Monteriggioni, Italy
关键词
ESR; Westergren; interference; methods comparison; stability; INTERFERENCE; VALIDATION; PHASE;
D O I
10.1080/00365513.2024.2422397
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The erythrocyte sedimentation rate (ESR) is a widely used diagnostic test, influenced by all physiological and pathological conditions that can bias blood rheology by interfering factors. This study aimed to evaluate the performance of the CUBE 30 touch ESR analyzer in samples with preanalytical variables, as lipemia, hemolysis, and icterus or in presence of fibrinogen., Moreover we focused to define the maximum time limits to ensure a reliable ESR measure. Accuracy, intra-run and inter-run precision, and stability studies were performed. Moreover, hemolytic, jaundiced, lipemic samples and fibrinogen sensitivity were analyzed for interference study. Statistical analyses were performed. CUBE 30 touch and Westergren method comparison showed no statistical differences (Spearman Coefficient, R2=0,95). In the intra-run precision, the CV% mean obtained on samples with normal ESR level was 8,9%; with middle ESR level was 5,9% and with high ESR level the CV% was 4,3%. Inter-run precision test showed CV% of for single samples and overall samples in the range (12,3% for normal level and 4,8% for abnormal level). The samples stored at 4 degrees C showed good stability up to 3 h from collecting time. ESR samples showing lipemia, hemolysis or jaundice showed good correlations with the gold standard method (R2 0,901, 0,940, 0,911; p < 0,0001), however, Westergren tests were more sensitive than CUBE 30 touch to fibrinogen additions. The high comparability with the Westergren method, both in normal and interfering samples, and the good precision, support the usefulness of CUBE 30 touch in the clinical routine laboratory.
引用
收藏
页码:477 / 485
页数:9
相关论文
共 50 条
  • [1] Analytical validation of the modified Westergren method on the automated erythrocyte sedimentation rate analyzer CUBE 30 touch
    Lapic, Ivana
    Rade, Anamarija
    Kraljevic, Andela
    Milos, Marija
    Herak, Desiree Coen
    Daskijevic, Lucija
    Cerovac, Paula
    Rogic, Dunja
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (08) : 1463 - 1469
  • [2] ISED, CUBE 30 touch and westergren: Comparison of different methodologies for measuring erythrocyte sedimentation rate (ESR)
    Miletic, M.
    Barberic, M.
    CLINICA CHIMICA ACTA, 2024, 558
  • [3] The Role of Erythrocyte Sedimentation Rate (ESR) in Myeloproliferative and Lymphoproliferative Diseases: Comparison between DIESSE CUBE 30 TOUCH and Alifax Test 1
    Pelagalli, Martina
    Tomassetti, Flaminia
    Nicolai, Eleonora
    Giovannelli, Alfredo
    Codella, Silvia
    Iozzo, Mariannina
    Massoud, Renato
    Secchi, Roberto
    Venditti, Adriano
    Pieri, Massimo
    Bernardini, Sergio
    Hatzimichael, Eleftheria
    DISEASES, 2023, 11 (04)
  • [4] Evaluation of Ves-Matic Cube 200 For Erythrocyte Sedimentation Rate Determination
    Sezer, Sevilay
    Yilmaz, Fatma Meric
    Kaya, Oguzhan
    Uysal, Sema
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2013, 27 (05) : 367 - 372
  • [5] Evaluation of the Diesse Cube 30 touch erythrocyte sedimentation method in comparison with Alifax test 1 and the manual Westergren gold standard method
    Pieri, Massimo
    Pignalosa, Stefano
    Perrone, Marco Alfonso
    Russo, Carmelo
    Noce, Gianluca
    Perrone, Andrea
    Terrinoni, Alessandro
    Massoud, Renato
    Bernardini, Sergio
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (03): : 181 - 186
  • [6] MEASUREMENT OF ERYTHROCYTE SEDIMENTATION RATE (ESR) IN EDTA AND CITRATE BLOOD - COMPARISON OF VESMATIC 30, VESMATIC CUBE 30 AND VESMATIC CUBE 80 ANALYZERS
    Perovic, E.
    Sambunjak, J.
    Coza, M.
    Valcic, A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S481 - S481
  • [7] Method Verification of the Caretium XC-A30 Automated Erythrocyte Sedimentation Rate Analyser for Erythrocyte Sedimentation Rate
    Khongwichit, Soemwit
    Saelim, Menapha
    Na Songkhla, Yanisa
    Buncherd, Hansuk
    Nopparatana, Chawadee
    Srinoun, Kanitta
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2022, 29 (05): : 39 - 47
  • [8] Evaluation of Ves-Matic Cube 200-an automated system for the measurement of the erythrocyte sedimentation rate
    Perovic, E.
    Bakovic, L.
    Valcic, A.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (01) : 88 - 94
  • [9] Validation of the New MINI-CUBE for Clinic Determination of Erythrocyte Sedimentation Rate
    Tomassetti, Flaminia
    Pelagalli, Martina
    Nicolai, Eleonora
    Sarubbi, Serena
    Calabrese, Cinzia
    Giovannelli, Alfredo
    Codella, Silvia
    Viola, Gemma
    Diamanti, Daniela
    Massoud, Renato
    Bernardini, Sergio
    Pieri, Massimo
    JOURNAL OF HEMATOLOGY, 2023, 12 (05) : 208 - 214
  • [10] Evaluation of an automated erythrocyte sedimentation rate analyzer as compared to the Westergren manual method in measurement of erythrocyte sedimentation rate
    Subramanian, Arulselvi
    Rangarajan, Kanchana
    Pandey, Ravindra Mohan
    Gandhi, Jatin S.
    Sharma, Vijay
    Bhoi, Sanjeev Kumar
    INDIAN JOURNAL OF PATHOLOGY AND MICROBIOLOGY, 2011, 54 (01) : 70 - 74