Punching shear performance of reinforced concrete slab-to-steel column connections incorporating ECC and UHPECC

被引:2
|
作者
Hamoda, Ahmed [1 ]
Abadel, Aref A. [2 ]
Ahmed, Mizan [3 ]
Wang, Vincent [4 ]
Vrcelj, Zora [4 ]
Liang, Qing Quan [4 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Dept Civil Engn, Kafrelsheikh, Egypt
[2] King Saud Univ, Coll Engn, Dept Civil Engn, Riyadh 11421, Saudi Arabia
[3] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[4] Victoria Univ, Coll Sport Hlth & Engn, POB 14428, Melbourne, Vic 8001, Australia
关键词
Punching shear; High-performance concrete; Engineered cementitious composite; Nonlinear finite element modeling; NUMERICAL ASSESSMENT; BEHAVIOR; CFRP;
D O I
10.1016/j.engstruct.2024.119145
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unlike the conventional reinforced concrete (RC) slab-column connection, the punching shear generated at the RC slab-to-steel column connection may lead to brittle punching shear failure due to the small area around the steel column. Moreover, the unexpected moments arising from eccentric loading can also lead to the failure of the slab in punching shear mode. This paper proposes employing high-performance concrete (HPC) to fill the critical punching shear zone to improve the punching shear resistance of RC slabs to steel column joints. Experiments on eight RC slabs to steel column connections are reported. The test parameters under investigation are the type of HPC used to fill the critical punching shear zone, the distance (S) of the HPC zone measured from the flanges of the steel column and loading condition (concentric and eccentric). The types of HPC include engineered cementitious composite (ECC) and ultra-high performance ECC (UHPECC). The experimental results show that the proposed techniques can significantly improve the cracking load, elastic stiffness, energy absorption capacity, ductility, failure modes, and ultimate load of the slab-to-column connections. The ultimate load of the tested connections is increased by as much as 33 %, and 28 % for the slabs subjected to concentric and eccentric loading, respectively. However, the ultimate load and energy absorption capacity of the slab with UHPECC having a S value of 1d, where d is the effective depth are lower than those of the control slab. Three-dimensional nonlinear finite element models are developed to simulate the performance of tested slab-to-column connections and validated by experimental results. The parametric study shows that the n (=S/d) value greater than 3.5 has insignificant effects on the ultimate punching shear capacity of the slab. It is demonstrated that the proposed formulas faithfully estimate the ultimate punching shear capacity of slab-to-column connections constructed with different HPCs under concentric and eccentric loadings.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections
    Long Nguyen-Minh
    Rovnak, Marian
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) : 2 - 13
  • [22] Punching of reinforced and post-tensioned concrete slab-column connections
    Kang, THK
    Wallace, JW
    ACI STRUCTURAL JOURNAL, 2006, 103 (04) : 531 - 540
  • [23] Application of FRP for Punching Shear Retrofit of Concrete Slab-Column Connections
    Polak, Maria Anna
    Lawler, Nicholas
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 854 - +
  • [24] Punching shear behavior of RC slab-column connections enhanced with ECC in core area
    Su, Yanli
    Wang, Xinru
    Wu, Chang
    Xu, Mingwen
    Ma, Lai
    Jin, Chenhua
    STRUCTURES, 2025, 74
  • [25] Punching shear behavior of slab-column connections embedded with steel skeletons
    Zhou, Li
    Huang, Yong
    Chen, Bo
    STRUCTURES, 2021, 33 : 2879 - 2892
  • [26] Punching shear behaviour of steel-concrete composite slab-column connections with spatial steel drop panel
    Chen, Jianwei
    Zhang, Rui
    Wang, Zhanwen
    Wu, Shan
    ENGINEERING STRUCTURES, 2023, 283
  • [27] Numerical Modelling of the Punching Shear Response of Shearhead Connections between a CFT Column and a Flat Reinforced Concrete Slab
    Nguyen-The, Danh
    Thai, Son
    Nguyen-Van, Hieu
    Ngo-Huu, Cuong
    STRUCTURAL ENGINEERING INTERNATIONAL, 2024,
  • [28] Punching shear strength of ultra-high-performance fibre concrete slab-column connections
    Shoukry, Mohie E.
    Tarabia, Ahmed M.
    Yassin, Ahmed M.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2022, 175 (08) : 644 - 656
  • [29] Punching shear behavior and corrosion resistance of composite slab-column connections reinforced by BFRP and steel rebar
    Qian, Kai
    Weng, Yun-Hao
    Liang, Shi-Lin
    Fu, Feng
    ENGINEERING STRUCTURES, 2024, 304
  • [30] PUNCHING SHEAR ANALYSIS OF SLAB-COLUMN CONNECTIONS
    Moreno, Carlos L.
    Sarmento, Ana M.
    CORAN 2011: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN NONLINEAR MODELS - STRUCTURAL CONCRETE APPLICATIONS, 2011, : 267 - 279