Punching of reinforced and post-tensioned concrete slab-column connections

被引:0
|
作者
Kang, THK [1 ]
Wallace, JW [1 ]
机构
[1] Univ Calif Los Angeles, Los Angeles, CA 90024 USA
关键词
columns; reinforcement; seismic; slabs;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Data collected from shaketable tests of two, approximately 1/3-scale, two-story flat plate frames using shear reinforcement, as well as data from previous tests, were evaluated to assess the interstory drift ratios when punching failures occur for reinforced concrete and post-tensioned slab-column connections with and without shear reinforcement. The drift ratios at punching failures for the two shaketable specimens were approximately equal to values reported for quasi-static tests of isolated specimens without shear reinforcement; but substantially less than reported for quasi-static tests of connections with shear reinforcement. The review of test results indicates that the bilinear relation for lateral drift versus gravity shear ratio to assess the need for shear reinforcement at slab-column connections approved for ACI 318-05, Section 21.11, is generally conservative for typical connections of all connection types. The data also were used to assess parameters required for a simple shear-strength degrading model for slab-column. connections.
引用
收藏
页码:531 / 540
页数:10
相关论文
共 50 条
  • [1] Punching of reinforced and post-tensioned concrete slab-column connections.
    Kang, Thomas H. -K.
    Wallace, John W.
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 366 - 367
  • [2] Punching Shear Strength of Post-Tensioned Transfer Slab-Column Connections
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    Kang, Thomas H-K
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (07)
  • [3] Punching shear strength of corroded reinforced concrete slab-column connections
    Qian, Kai
    Li, Jin-Song
    Huang, Ting
    Weng, Yun-Hao
    Deng, Xiao-Fang
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [4] Punching Shear Capacity Analysis of Reinforced Concrete Slab-column Connections
    Guo, Huiyong
    Cheng, Jinjun
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ADVANCED ENGINEERING MATERIALS AND TECHNOLOGY, 2015, 38 : 244 - 248
  • [5] Seismic fragility assessment of reinforced concrete and post-tensioned slab-column connections - reliability-based formulations for storey drift limits
    Genikomsou, Aikaterini S.
    Abdelmaksoud, Ahmed M.
    Balomenos, Georgios P.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2025, 23 (01) : 241 - 273
  • [6] Seismic Performance of Bonded Post-Tensioned Slab-Column Connections with and without Drop Panels
    Prawatwong, Unnop
    Warnitchai, Pennung
    Tandian, Chondro Hidayat
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (10) : 1653 - 1672
  • [7] Numerical investigation on the structural performance of post-tensioned precast concrete two-way slab-column connections
    Zhou, Mi
    Hrynyk, Trevor D.
    STRUCTURES, 2024, 69
  • [8] Rehabilitation of reinforced concrete slab-column connections
    El-Salakawy, EF
    Polak, MA
    Soudki, KA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (04) : 602 - 611
  • [9] Punching shear strength of interior concrete slab-column connections reinforced with steel fibers
    Choi, Kyoung-Kyu
    Taha, Mahmoud M. Reda
    Park, Hong-Gun
    Maji, Arup K.
    CEMENT & CONCRETE COMPOSITES, 2007, 29 (05): : 409 - 420
  • [10] Punching shear strength of reinforced concrete transfer slab-column connections with shear reinforcement
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2021, 243