Punching shear performance of reinforced concrete slab-to-steel column connections incorporating ECC and UHPECC

被引:2
|
作者
Hamoda, Ahmed [1 ]
Abadel, Aref A. [2 ]
Ahmed, Mizan [3 ]
Wang, Vincent [4 ]
Vrcelj, Zora [4 ]
Liang, Qing Quan [4 ]
机构
[1] Kafrelsheikh Univ, Fac Engn, Dept Civil Engn, Kafrelsheikh, Egypt
[2] King Saud Univ, Coll Engn, Dept Civil Engn, Riyadh 11421, Saudi Arabia
[3] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil & Mech Engn, Kent St, Bentley, WA 6102, Australia
[4] Victoria Univ, Coll Sport Hlth & Engn, POB 14428, Melbourne, Vic 8001, Australia
关键词
Punching shear; High-performance concrete; Engineered cementitious composite; Nonlinear finite element modeling; NUMERICAL ASSESSMENT; BEHAVIOR; CFRP;
D O I
10.1016/j.engstruct.2024.119145
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unlike the conventional reinforced concrete (RC) slab-column connection, the punching shear generated at the RC slab-to-steel column connection may lead to brittle punching shear failure due to the small area around the steel column. Moreover, the unexpected moments arising from eccentric loading can also lead to the failure of the slab in punching shear mode. This paper proposes employing high-performance concrete (HPC) to fill the critical punching shear zone to improve the punching shear resistance of RC slabs to steel column joints. Experiments on eight RC slabs to steel column connections are reported. The test parameters under investigation are the type of HPC used to fill the critical punching shear zone, the distance (S) of the HPC zone measured from the flanges of the steel column and loading condition (concentric and eccentric). The types of HPC include engineered cementitious composite (ECC) and ultra-high performance ECC (UHPECC). The experimental results show that the proposed techniques can significantly improve the cracking load, elastic stiffness, energy absorption capacity, ductility, failure modes, and ultimate load of the slab-to-column connections. The ultimate load of the tested connections is increased by as much as 33 %, and 28 % for the slabs subjected to concentric and eccentric loading, respectively. However, the ultimate load and energy absorption capacity of the slab with UHPECC having a S value of 1d, where d is the effective depth are lower than those of the control slab. Three-dimensional nonlinear finite element models are developed to simulate the performance of tested slab-to-column connections and validated by experimental results. The parametric study shows that the n (=S/d) value greater than 3.5 has insignificant effects on the ultimate punching shear capacity of the slab. It is demonstrated that the proposed formulas faithfully estimate the ultimate punching shear capacity of slab-to-column connections constructed with different HPCs under concentric and eccentric loadings.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Punching Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Interior Connections
    Hussein, Ahmed H.
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2018, 115 (04) : 1075 - 1088
  • [32] Punching shear analysis of slab-column connections
    Moreno, Carlos L.
    Sarmento, Ana M.
    ENGINEERING COMPUTATIONS, 2013, 30 (06) : 802 - 814
  • [33] CONTRIBUTION OF STEEL FIBERS TO THE STRENGTH CHARACTERISTICS OF LIGHTWEIGHT CONCRETE SLAB-COLUMN CONNECTIONS FAILING IN PUNCHING SHEAR
    THEODORAKOPOULOS, DD
    SWAMY, N
    ACI STRUCTURAL JOURNAL, 1993, 90 (04) : 342 - 355
  • [34] Analysis on punching shear behavior of an innovative connection between T-shaped steel reinforced concrete column and reinforced concrete slab
    Xue J.
    Zhang W.
    Zhang C.
    Zhao F.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (06): : 1 - 13
  • [35] A design model for punching shear of FRP-reinforced slab-column connections
    Theodorakopoulos, D. D.
    Swamy, R. N.
    CEMENT & CONCRETE COMPOSITES, 2008, 30 (06): : 544 - 555
  • [36] Punching shear capacity of recycled-aggregate concrete slab-column connections
    Sahoo, Saumyaranjan
    Singh, Bhupinder
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [37] Punching of reinforced and post-tensioned concrete slab-column connections.
    Kang, Thomas H. -K.
    Wallace, John W.
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 366 - 367
  • [38] Punching shear strength of flat slab corner column connections. Part 2. Fibre-reinforced concrete connections
    Indian Inst of Science, Bangalore, India
    Proc Inst Civ Eng Struct Build, 1 (21-26):
  • [39] Reinforced concrete slab-column edge connections with shear studs
    El-Salakawy, EF
    Polak, MA
    Soliman, MH
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (02) : 338 - 348
  • [40] Performance of reinforced concrete flat slab strengthened with CFRP for punching shear
    Ghayeb, Haider Hamad
    Atea, Rafid Saeed
    Al-Kannoon, Muslim Abdul-Ameer
    Lee, Foo Wei
    Wong, Leong Sing
    Mo, Kim Hung
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 18