An Artifact in Concentric Needle EMG Recordings

被引:1
|
作者
Nandedkar, Sanjeev D. [1 ,2 ]
Barkhaus, Paul E. [2 ]
机构
[1] Natus Med Inc, Hopewell Jct, NY 12533 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53226 USA
关键词
amplitude; asymmetry; cannula potential; concentric needle; electromyography; needle electrode artifact; AUTOMATIC-ANALYSIS; MACRO EMG;
D O I
10.1002/mus.28312
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/Aims In healthy subjects, we observed high amplitude motor unit potential (MUP) waveforms that resembled the cannula potential (CP) with a positive sharp wave (PSW)-like waveform. We analyzed the source of this signal, its prevalence, and its effects on the analysis of electromyographic waveforms. Methods Three channel recordings were performed to explore the contribution of the needle core and cannula to the MUP. In 7 control subjects with no neuromuscular disease, the EMG interference pattern was quantified for the amplitude asymmetry (AASM) of its positive and negative going peaks. Results The large amplitude MUP resembling a CP with a PSW-type waveform is recorded by the needle core, not the cannula. With a slight change in needle position, its amplitude decreased and the waveform had a normal appearance. Thus, it is an artifact. Such potentials (AASM > 150%) are commonly encountered (frequency 7%) and occur in all muscles and subjects in this study. Discussion The artifact is an enigma and appears related to the interaction between the needle and muscle fiber(s) similar to that in PSW signals. Failure to recognize these waveforms may result in a false impression of abnormality. AASM calculations can help confirm this artifact in automated analysis algorithms to preclude false positive neurogenic patterns.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 50 条
  • [41] Acceleration driven adaptive filter to remove motion artifact from EMG recordings in Whole Body Vibration
    Fratini, A.
    Cesarelli, M.
    Bifulco, P.
    La Gatta, A.
    Romano, M.
    Pasquariello, G.
    11TH MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2007, VOLS 1 AND 2, 2007, 16 (1-2): : 990 - 993
  • [42] PRINCIPAL COMPONENT ANALYSIS OF THE FEATURES OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    SANDERS, DB
    MUSCLE & NERVE, 1989, 12 (04) : 288 - 293
  • [43] EMG RECORDINGS FROM ESOPHAGUS
    ARLAZOROFF, A
    RAPPOPORT, Y
    SHANON, E
    STREIFLER, M
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1971, 7 (11): : 1322 - +
  • [44] THE USE OF CONCENTRIC NEEDLE ELECTRODE (CNE) ELECTROMYOGRAPHIC (EMG) STUDIES OF THE STRIATED-MUSCLE OF THE URETHRAL SPHINCTER
    FOWLER, CJ
    HARRISON, MJG
    KIRBY, RS
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1984, 58 (01): : P19 - P19
  • [45] Needle EMG muscle identification: A systematic approach to needle EMG examination
    Menkes, Daniel L.
    Pierce, Robert
    CLINICAL NEUROPHYSIOLOGY PRACTICE, 2019, 4 : 199 - 211
  • [46] Whither needle EMG?
    Burke, David
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (09) : 1373 - 1375
  • [47] Classification of Neuromuscular Diseases in Neuromuscular Junction and Tendon Recordings with Needle EMG by Using Welch's Method
    Artug, Tugrul
    Osman, Onur
    Goker, Imran
    Baslo, Baris
    2017 MEDICAL TECHNOLOGIES NATIONAL CONGRESS (TIPTEKNO), 2017,
  • [48] NEEDLE EMG OF THE DIAPHRAGM
    SAADEH, PB
    CRISAFULLI, C
    GAROFALO, M
    MUSCLE & NERVE, 1993, 16 (03) : 323 - 324
  • [49] BIOFEEDBACK - SPECTRAL CONDITIONING OF EMG ARTIFACT
    GRISOLIA, J
    BICKFORD, R
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1977, 43 (06): : 904 - 904
  • [50] Ambulatory device for surface EMG recordings
    Airaksinen, Olavi
    Airaksinen, Kaisa
    Acupuncture and Electro-Therapeutics Research, 1998, 23 (01): : 9 - 18