An Artifact in Concentric Needle EMG Recordings

被引:1
|
作者
Nandedkar, Sanjeev D. [1 ,2 ]
Barkhaus, Paul E. [2 ]
机构
[1] Natus Med Inc, Hopewell Jct, NY 12533 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53226 USA
关键词
amplitude; asymmetry; cannula potential; concentric needle; electromyography; needle electrode artifact; AUTOMATIC-ANALYSIS; MACRO EMG;
D O I
10.1002/mus.28312
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/Aims In healthy subjects, we observed high amplitude motor unit potential (MUP) waveforms that resembled the cannula potential (CP) with a positive sharp wave (PSW)-like waveform. We analyzed the source of this signal, its prevalence, and its effects on the analysis of electromyographic waveforms. Methods Three channel recordings were performed to explore the contribution of the needle core and cannula to the MUP. In 7 control subjects with no neuromuscular disease, the EMG interference pattern was quantified for the amplitude asymmetry (AASM) of its positive and negative going peaks. Results The large amplitude MUP resembling a CP with a PSW-type waveform is recorded by the needle core, not the cannula. With a slight change in needle position, its amplitude decreased and the waveform had a normal appearance. Thus, it is an artifact. Such potentials (AASM > 150%) are commonly encountered (frequency 7%) and occur in all muscles and subjects in this study. Discussion The artifact is an enigma and appears related to the interaction between the needle and muscle fiber(s) similar to that in PSW signals. Failure to recognize these waveforms may result in a false impression of abnormality. AASM calculations can help confirm this artifact in automated analysis algorithms to preclude false positive neurogenic patterns.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 50 条
  • [31] THE TIME COURSE OF CREATINE-KINASE ELEVATION FOLLOWING CONCENTRIC NEEDLE EMG
    LEVIN, R
    PASCUZZI, RM
    BRUNS, DE
    BOYD, JC
    TOLY, TM
    PHILLIPS, LH
    MUSCLE & NERVE, 1987, 10 (03) : 242 - 245
  • [32] Jitter patterns in conventional concentric needle electromyography recordings of regenerating motor units
    Posa, Andreas
    Temneanu, Andrej
    Emmer, Alexander
    Langer, Thomas
    Kornhuber, Malte
    MUSCLE & NERVE, 2020, 62 (05) : 593 - 596
  • [33] ECG Artifact Removal from EMG Recordings using Independent Component Analysis and Adapted Filter
    Li, Yun
    Chen, Xiang
    Zhang, Xu
    Zhou, Ping
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 347 - 350
  • [34] A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings
    Íñigo Corera
    Adrián Eciolaza
    Oliver Rubio
    Armando Malanda
    Javier Rodríguez-Falces
    Javier Navallas
    Medical & Biological Engineering & Computing, 2018, 56 : 1391 - 1402
  • [35] A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings
    Corera, Inigo
    Eciolaza, Adrian
    Rubio, Oliver
    Malanda, Armando
    Rodriguez-Falces, Javier
    Navallas, Javier
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (08) : 1391 - 1402
  • [36] Quantitative EMG and motor unit recruitment threshold using a concentric needle with quadrifilar electrode
    Akaboshi, K
    Masakado, Y
    Chino, N
    MUSCLE & NERVE, 2000, 23 (03) : 361 - 367
  • [37] Single Fibre EMG with a Concentric Needle Electrode: An Alternative Method for the Diagnosis of Myasthenia Gravis
    Bischoff, C.
    KLINISCHE NEUROPHYSIOLOGIE, 2011, 42 (04) : 212 - 214
  • [38] ANALYSIS OF AMPLITUDE AND AREA OF CONCENTRIC NEEDLE EMG MOTOR UNIT ACTION-POTENTIALS
    NANDEDKAR, SD
    BARKHAUS, PE
    SANDERS, DB
    STALBERG, EV
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 69 (06): : 561 - 567
  • [39] Concentric-needle versus macro EMG II. Detection of neuromuscular disorders
    Finsterer, J
    Fuglsang-Frederiksen, A
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (05) : 853 - 860
  • [40] COMPUTERIZED EMG RECORDINGS
    SALKOWSKA, ES
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1982, 12 (02) : 41 - 41