An Artifact in Concentric Needle EMG Recordings

被引:1
|
作者
Nandedkar, Sanjeev D. [1 ,2 ]
Barkhaus, Paul E. [2 ]
机构
[1] Natus Med Inc, Hopewell Jct, NY 12533 USA
[2] Med Coll Wisconsin, Milwaukee, WI 53226 USA
关键词
amplitude; asymmetry; cannula potential; concentric needle; electromyography; needle electrode artifact; AUTOMATIC-ANALYSIS; MACRO EMG;
D O I
10.1002/mus.28312
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/Aims In healthy subjects, we observed high amplitude motor unit potential (MUP) waveforms that resembled the cannula potential (CP) with a positive sharp wave (PSW)-like waveform. We analyzed the source of this signal, its prevalence, and its effects on the analysis of electromyographic waveforms. Methods Three channel recordings were performed to explore the contribution of the needle core and cannula to the MUP. In 7 control subjects with no neuromuscular disease, the EMG interference pattern was quantified for the amplitude asymmetry (AASM) of its positive and negative going peaks. Results The large amplitude MUP resembling a CP with a PSW-type waveform is recorded by the needle core, not the cannula. With a slight change in needle position, its amplitude decreased and the waveform had a normal appearance. Thus, it is an artifact. Such potentials (AASM > 150%) are commonly encountered (frequency 7%) and occur in all muscles and subjects in this study. Discussion The artifact is an enigma and appears related to the interaction between the needle and muscle fiber(s) similar to that in PSW signals. Failure to recognize these waveforms may result in a false impression of abnormality. AASM calculations can help confirm this artifact in automated analysis algorithms to preclude false positive neurogenic patterns.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 50 条
  • [1] JITTER RECORDINGS WITH CONCENTRIC NEEDLE ELECTRODES
    Stalberg, Erik V.
    Sanders, Donald B.
    MUSCLE & NERVE, 2009, 40 (03) : 331 - 339
  • [2] CONCENTRIC NEEDLE EMG IN REINNERVATING AND DENERVATING MOTOR UNITS
    NANDEDKAR, SD
    SANDERS, DB
    STALBERG, EV
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 61 (03): : S243 - S243
  • [3] Comparison between concentric needle EMG and macro EMG in patients with a history of polio
    Sandberg, A
    Hansson, B
    Stålberg, E
    CLINICAL NEUROPHYSIOLOGY, 1999, 110 (11) : 1900 - 1908
  • [4] Comparison of sensitivities of macro EMG and concentric needle EMG in L4 radiculopathy
    U. H. Ulas
    B. Cengiz
    E. Alanoglu
    M. F. Ozdag
    Z. Odabasi
    O. Vural
    Neurological Sciences, 2003, 24 : 258 - 260
  • [5] Comparison of sensitivities of macro EMG and concentric needle EMG in L4 radiculopathy
    Ulas, UH
    Cengiz, B
    Alanoglu, E
    Ozdag, MF
    Odabasi, Z
    Vural, O
    NEUROLOGICAL SCIENCES, 2003, 24 (04) : 258 - 260
  • [6] Concentric needle EMG versus macro EMG - I. Relation in healthy subjects
    Finsterer, J
    Fuglsang-Frederiksen, A
    CLINICAL NEUROPHYSIOLOGY, 2000, 111 (07) : 1211 - 1215
  • [7] Single fiber EMG and measuring jitter with concentric needle electrodes
    Sanders, Donald B.
    Kouyoumdjian, Joao A.
    Stalberg, Erik V.
    MUSCLE & NERVE, 2022,
  • [8] RECORDING AND PHYSICAL CHARACTERISTICS OF DISPOSABLE CONCENTRIC NEEDLE EMG ELECTRODES
    NANDEDKAR, SD
    TEDMAN, B
    SANDERS, DB
    MUSCLE & NERVE, 1990, 13 (10) : 909 - 914
  • [9] AUTOMATIC-ANALYSIS CONCENTRIC NEEDLE EMG DURING RECRUITMENT
    BARBIERI, S
    ETZION, N
    FIGINI, MM
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1987, 66 (03): : P35 - P35
  • [10] Comparison of standard and pediatric size concentric needle EMG electrodes
    Brownell, Alexander A.
    Bromberg, Mark B.
    CLINICAL NEUROPHYSIOLOGY, 2007, 118 (05) : 1162 - 1165