Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

被引:0
|
作者
Xu, Manman [1 ]
Cao, Chuqing [2 ]
Fu, Yili [3 ]
Wu, Yonghong [4 ]
Wang, Xiangdong [5 ]
Su, Yongsheng [1 ]
Xi, Lin [1 ]
Liu, Yongming [1 ]
机构
[1] Anhui Polytech Univ, Sch Mech Engn, Wuhu 241000, Peoples R China
[2] Wuhu HIT Robot Technol Res Inst Co LTD, Wuhu 241000, Peoples R China
[3] Harbin Inst Technol, Harbin 150001, Peoples R China
[4] Anhui Univ Sci & Technol, Anhui Key Lab Mine Intelligent Equipment & Technol, Huainan 232001, Peoples R China
[5] Wuhu Magnet Wheel Transmiss Technol Co LTD, Wuhu 241000, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic field mapping; Measurement accuracy; Polynomial fitting; Probe calibration; Superconducting cyclotron;
D O I
10.2478/nuka-2024-0026
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
IntroductionSuperconducting cyclotron can generate high-energy proton beams and are mainly used for radiation therapy of tumors and cancers. In the superconducting cyclotron SC200, the maximum magnetic induction intensity can typically reach up to 4.6 T, and the magnetic field accuracy is 1e-4. Hall probes are commonly used tools for measuring high-intensity magnetic fields.ObjectiveThrough comprehensive consideration, this study selects the SENIS Low-Noise Teslameter 3MH5 and Hall probe C to measure the magnetic field. When the magnetic field exceeds the range of 2 T, the measurement accuracy of the Hall probe is less than 1e-4, and the Hall probe needs to be calibrated to improve its measurement accuracy.MethodsThe Hall probes are calibrated using Swiss METROLAB PT2025 nuclear magnetic resonance (NMR) Tesla instrument and 1062 probe. Based on the calibration principle, a calibration system platform was built, test data were collected, and calibration curves were obtained. At the same time, the calibration data were analyzed through cross-validation experiments using the cubic polynomial fitting method.ResultsThe results indicate that the test deviation range is from -0.1 g to 0.1 g, and the measurement accuracy can reach 1e-4.ConclusionIn summary, the Hall probe can accurately measure the magnetic field distribution of the superconducting cyclotron. It can provide accurate and important data for the calculation and analysis of particle beam dynamics.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [41] High-Stability and High-Precision Power Supply for Superconducting Coils of SC200 Cyclotron
    Pan, Sheng Min
    Huang, Yi Yun
    Wang, Denghui
    Ruan, Jiu Fu
    2023 IEEE BELGRADE POWERTECH, 2023,
  • [42] Light source system for high-precision flat-field correction and the calibration of an array detector
    杨福桂
    王秋实
    李明
    Chinese Optics Letters, 2015, 13 (04) : 10 - 14
  • [43] High accuracy magnetic field measurements with a Hall probe
    Schott, C
    Popovic, RS
    Alberti, S
    Tran, MQ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (06): : 2703 - 2707
  • [44] High accuracy magnetic field measurements with a Hall probe
    Schott, C.
    Popovic, R.S.
    Alberti, S.
    Tran, M.Q.
    Review of Scientific Instruments, 70 (06):
  • [45] An Integrated High-Precision Probe System in 0.18-μm CMOS for Near-Field Magnetic Measurements on Cryptographic LSIs
    Nguyen Ngoc Mai-Khanh
    Iizuka, Tetsuya
    Yamada, Makoto
    Morita, Osamu
    Asada, Kunihiro
    IEEE SENSORS JOURNAL, 2013, 13 (07) : 2675 - 2682
  • [46] TEST OF NEW ACCELERATOR SUPERCONDUCTING DIPOLES SUITABLE FOR HIGH-PRECISION FIELD
    PATOUX, A
    PEROT, J
    RIFFLET, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (04) : 3681 - 3683
  • [47] Field Mapping System Design for the Superconducting Cyclotron CYCIAE-230
    Li, Ming
    Lv, Yinlong
    Cao, Lei
    Zhang, Tianjue
    Xing, Jiansheng
    Tinembart, Jacques
    Cui, Tao
    Wang, Chuan
    Wang, Fei
    Guan, Leilei
    Yin, Zhiguo
    Gong, Pengfei
    Yang, Guang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
  • [48] High-precision calibration method for position and attitude angle of magnetic beacon
    Zheng Y.
    Li Q.
    Wang C.
    Yu W.
    Sun Q.
    Zhongguo Guanxing Jishu Xuebao/Journal of Chinese Inertial Technology, 2020, 28 (03): : 353 - 359
  • [49] Positional calibration of Hall probes for magnetic field measurement of a superconducting undulator in SHINE
    Wu Z.
    Zhang J.
    Chen J.
    Zhou Q.
    He Jishu/Nuclear Techniques, 2023, 46 (09):
  • [50] A High-Precision Calibration Method for Spectrometers
    Perret, Edith
    Balmer, Tobias E.
    AMERICAN LABORATORY, 2011, 43 (05) : 44 - 45