Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

被引:0
|
作者
Xu, Manman [1 ]
Cao, Chuqing [2 ]
Fu, Yili [3 ]
Wu, Yonghong [4 ]
Wang, Xiangdong [5 ]
Su, Yongsheng [1 ]
Xi, Lin [1 ]
Liu, Yongming [1 ]
机构
[1] Anhui Polytech Univ, Sch Mech Engn, Wuhu 241000, Peoples R China
[2] Wuhu HIT Robot Technol Res Inst Co LTD, Wuhu 241000, Peoples R China
[3] Harbin Inst Technol, Harbin 150001, Peoples R China
[4] Anhui Univ Sci & Technol, Anhui Key Lab Mine Intelligent Equipment & Technol, Huainan 232001, Peoples R China
[5] Wuhu Magnet Wheel Transmiss Technol Co LTD, Wuhu 241000, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic field mapping; Measurement accuracy; Polynomial fitting; Probe calibration; Superconducting cyclotron;
D O I
10.2478/nuka-2024-0026
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
IntroductionSuperconducting cyclotron can generate high-energy proton beams and are mainly used for radiation therapy of tumors and cancers. In the superconducting cyclotron SC200, the maximum magnetic induction intensity can typically reach up to 4.6 T, and the magnetic field accuracy is 1e-4. Hall probes are commonly used tools for measuring high-intensity magnetic fields.ObjectiveThrough comprehensive consideration, this study selects the SENIS Low-Noise Teslameter 3MH5 and Hall probe C to measure the magnetic field. When the magnetic field exceeds the range of 2 T, the measurement accuracy of the Hall probe is less than 1e-4, and the Hall probe needs to be calibrated to improve its measurement accuracy.MethodsThe Hall probes are calibrated using Swiss METROLAB PT2025 nuclear magnetic resonance (NMR) Tesla instrument and 1062 probe. Based on the calibration principle, a calibration system platform was built, test data were collected, and calibration curves were obtained. At the same time, the calibration data were analyzed through cross-validation experiments using the cubic polynomial fitting method.ResultsThe results indicate that the test deviation range is from -0.1 g to 0.1 g, and the measurement accuracy can reach 1e-4.ConclusionIn summary, the Hall probe can accurately measure the magnetic field distribution of the superconducting cyclotron. It can provide accurate and important data for the calculation and analysis of particle beam dynamics.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [21] High-precision mapping of the magnetic field utilizing the harmonic function mean value property
    Li, L
    Leigh, JS
    JOURNAL OF MAGNETIC RESONANCE, 2001, 148 (02) : 442 - 448
  • [22] High-precision measurement of magnetic penetration depth in superconducting films
    He, X.
    Gozar, A.
    Sundling, R.
    Bozovic, I.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [23] A NEW ACCELERATOR SUPERCONDUCTING DIPOLE SUITABLE FOR HIGH-PRECISION FIELD
    PATOUX, A
    PEROT, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 3205 - 3207
  • [24] A NEW ACCELERATOR SUPERCONDUCTING DIPOL SUITABLE FOR HIGH-PRECISION FIELD
    PEROT, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 153 - 153
  • [25] System Calibration of a Field Phenotyping Robot with Multiple High-Precision Profile Laser Scanners
    Esser, Felix
    Tombrink, Gereon
    Cornelissen, Andre
    Klingbeil, Lasse
    Kuhlmann, Heiner
    2024 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, ICRA 2024, 2024, : 8471 - 8477
  • [26] High-precision calibration of spectrographs
    Wilken, T.
    Lovis, C.
    Manescau, A.
    Steinmetz, T.
    Pasquini, L.
    Lo Curto, G.
    Haensch, T. W.
    Holzwarth, R.
    Udem, Th.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2010, 405 (01) : L16 - L20
  • [27] Calibration test method of high-precision accelerometer in gravitational field
    Jiang, Xiao-Xiong
    Liu, Yu
    Su, Bao-Ku
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2010, 40 (01): : 287 - 292
  • [28] Magnetic field measurement of superconducting dipolemagnets with harmonic coil and Hall probe
    Nakai, H
    Kabe, A
    Kojima, Y
    Hara, K
    Hosoyama, K
    Morita, Y
    Shintomi, T
    Terashima, A
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 389 - 396
  • [29] High-precision control of magnetic levitation system
    Jeon, JW
    Caraiani, M
    Lee, KC
    Hwang, DH
    Lee, JH
    Kim, YJ
    Nam, TK
    Kim, SS
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 2579 - 2584
  • [30] A HIGH-PRECISION MAGNETIC-FIELD MEASURING INSTRUMENT
    KANE, RW
    LEVINTHAL, EC
    RODGERS, EH
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1951, 39 (03): : 309 - 309