Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

被引:0
|
作者
Xu, Manman [1 ]
Cao, Chuqing [2 ]
Fu, Yili [3 ]
Wu, Yonghong [4 ]
Wang, Xiangdong [5 ]
Su, Yongsheng [1 ]
Xi, Lin [1 ]
Liu, Yongming [1 ]
机构
[1] Anhui Polytech Univ, Sch Mech Engn, Wuhu 241000, Peoples R China
[2] Wuhu HIT Robot Technol Res Inst Co LTD, Wuhu 241000, Peoples R China
[3] Harbin Inst Technol, Harbin 150001, Peoples R China
[4] Anhui Univ Sci & Technol, Anhui Key Lab Mine Intelligent Equipment & Technol, Huainan 232001, Peoples R China
[5] Wuhu Magnet Wheel Transmiss Technol Co LTD, Wuhu 241000, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic field mapping; Measurement accuracy; Polynomial fitting; Probe calibration; Superconducting cyclotron;
D O I
10.2478/nuka-2024-0026
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
IntroductionSuperconducting cyclotron can generate high-energy proton beams and are mainly used for radiation therapy of tumors and cancers. In the superconducting cyclotron SC200, the maximum magnetic induction intensity can typically reach up to 4.6 T, and the magnetic field accuracy is 1e-4. Hall probes are commonly used tools for measuring high-intensity magnetic fields.ObjectiveThrough comprehensive consideration, this study selects the SENIS Low-Noise Teslameter 3MH5 and Hall probe C to measure the magnetic field. When the magnetic field exceeds the range of 2 T, the measurement accuracy of the Hall probe is less than 1e-4, and the Hall probe needs to be calibrated to improve its measurement accuracy.MethodsThe Hall probes are calibrated using Swiss METROLAB PT2025 nuclear magnetic resonance (NMR) Tesla instrument and 1062 probe. Based on the calibration principle, a calibration system platform was built, test data were collected, and calibration curves were obtained. At the same time, the calibration data were analyzed through cross-validation experiments using the cubic polynomial fitting method.ResultsThe results indicate that the test deviation range is from -0.1 g to 0.1 g, and the measurement accuracy can reach 1e-4.ConclusionIn summary, the Hall probe can accurately measure the magnetic field distribution of the superconducting cyclotron. It can provide accurate and important data for the calculation and analysis of particle beam dynamics.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [31] High-Precision Magnetic Field Reconstruction and Anomaly Classification
    Chang, Qing
    Liu, Ruiping
    Wang, Yaoli
    Wang, Lipo
    IEEE SENSORS JOURNAL, 2023, 23 (17) : 19163 - 19175
  • [32] A LabVIEW based cyclotron magnetic field mapping system
    Marti, F
    Johnson, P
    CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 268 - 271
  • [33] High-Resolution Magnetic Field Mapping System With an NMR Probe
    Li, Frank X.
    Voccio, John P.
    Sammartino, Michael
    Jalali, Jalal
    Ahn, Min Cheol
    Hahn, Seungyong
    Bascunan, Juan
    Iwasa, Yukikazu
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [34] A high-precision calibration and optimization method for stereo vision system
    Zhou, Chuan
    Tan, Dalong
    Gao, Hongwei
    2006 9TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1- 5, 2006, : 388 - +
  • [35] Ground Calibration System Design of High-precision Star Sensor
    Duan, Jie
    An, Zhiyong
    Sun, Xiangyang
    MANUFACTURING PROCESS AND EQUIPMENT, PTS 1-4, 2013, 694-697 : 1068 - +
  • [36] Development and experiment of high-precision temperature and pressure calibration system
    Li, Jinyang
    Meng, Xiaofeng
    Yin, Kerong
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2013, 29 (SUPPL1): : 38 - 45
  • [37] A high-precision system level calibration method for spaceborne magnetometers
    Meng Lifei
    Xu Chaoqun
    Xiao Qi
    Liu Chaobo
    Geng Xiaolei
    Chen Dexiang
    Yi Zhong
    Zhang Tielong
    CHINESE SPACE SCIENCE AND TECHNOLOGY, 2024, 44 (03) : 174 - 179
  • [38] High-Precision Calibration Based on Multi-Camera System
    Xiao Yifan
    Hu Wei
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (20)
  • [39] A laser measurement system for the high-precision calibration of displacement transducers
    Brand, U
    Herrmann, K
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (06) : 911 - 917
  • [40] Light source system for high-precision flat-field correction and the calibration of an array detector
    Yang, Fugui
    Wang, Qiushi
    Li, Ming
    CHINESE OPTICS LETTERS, 2015, 13 (04)