Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

被引:0
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Severia, Nadya Maya [1 ]
Oktaviana, Citra Marantika Nur [1 ]
Puspitasari, Evrillia [1 ]
Ummah, Naftalia Wirdatul [1 ]
Alviani, Ziana [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Dept Chem, Campus C,Jl Dr Ir H Soekarno MERR, Surabaya 60115, Indonesia
关键词
cholesterol detection; electrometry; imprinted zeolite X; carbon paste electrode; health risk;
D O I
10.22146/ijc.99700
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10(-6)-10(-3) M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 x 10(-6) M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 mu M), precision of 96-99%, accuracy of 74-114%, sensitivity of 7.1 nA.L/mg/cm(2), and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.
引用
收藏
页码:482 / 496
页数:15
相关论文
共 50 条
  • [21] Voltammetric Determination of Uric Acid Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Motghare, Ramani V.
    Tadi, Kiran Kumar
    Dhawale, Payal
    Deotare, Samiksha
    Kawadkar, Aruna K.
    Chillawar, Rakesh
    Khan, Shirinaz
    ELECTROANALYSIS, 2015, 27 (03) : 825 - 832
  • [22] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Dehdashtian, Sara
    Hashemi, Beshare
    CHEMICAL PAPERS, 2020, 74 (01): : 157 - 165
  • [23] Voltammetric sensing of minoxidil using a molecularly imprinted polymer (MIP)-modified carbon paste electrode
    Sara Dehdashtian
    Beshare Hashemi
    Chemical Papers, 2020, 74 : 157 - 165
  • [24] Voltammetric determination of cysteine using carbon paste electrode modified with Co(II)-Y zeolite
    Nezamzadeh-Ejhieh, Alireza
    Hashemi, Habibeh-Sadat
    TALANTA, 2012, 88 : 201 - 208
  • [25] Novel Zeolite Modified Carbon Paste Electrode for Differential Pulse Voltammetric Assay of Cyclopentolate hydrochloride
    Al-Qahtani, Salhah D.
    Hameed, Ahmed
    Aljuhani, Enas
    Sayqal, Ali
    Shah, Reem
    Saad, Fawaz
    El-Metwaly, Nashwa M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (06): : 1 - 14
  • [26] Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions
    Pouretedal, HR
    Keshavarz, MH
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (01) : 28 - 31
  • [27] Iron Oxide Modified Carbon Paste Electrode Sensor for Guanine and Dopamine: A Voltammetric Technique
    Vishwanath, M. Shruthi
    Swamy, B. E. Kumara
    Vishnumurthy, K. A.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (06): : 444 - 457
  • [28] Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Kolbadinezhad, Mansureh
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (09) : 1411 - 1416
  • [29] Cadmium oxide nanoparticle modified carbon paste electrode sensor for sulfadiazine: A voltammetric study
    Manjunatha, L. S.
    Swamy, B. E. Kumara
    Manjunatha, K. G.
    INORGANIC CHEMISTRY COMMUNICATIONS, 2023, 150
  • [30] Carbon paste electrode modified with a binuclear manganese complex as a sensitive voltammetric sensor for tryptophan
    Xu, Jinsheng
    Yuan, Yali
    Li, Wei
    Deng, Peihong
    Deng, Jian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 239 - 245