Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

被引:0
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Severia, Nadya Maya [1 ]
Oktaviana, Citra Marantika Nur [1 ]
Puspitasari, Evrillia [1 ]
Ummah, Naftalia Wirdatul [1 ]
Alviani, Ziana [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Dept Chem, Campus C,Jl Dr Ir H Soekarno MERR, Surabaya 60115, Indonesia
关键词
cholesterol detection; electrometry; imprinted zeolite X; carbon paste electrode; health risk;
D O I
10.22146/ijc.99700
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10(-6)-10(-3) M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 x 10(-6) M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 mu M), precision of 96-99%, accuracy of 74-114%, sensitivity of 7.1 nA.L/mg/cm(2), and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.
引用
收藏
页码:482 / 496
页数:15
相关论文
共 50 条
  • [31] Carbon paste electrode modified with a binuclear manganese complex as a sensitive voltammetric sensor for tryptophan
    Jinsheng Xu
    Yali Yuan
    Wei Li
    Peihong Deng
    Jian Deng
    Microchimica Acta, 2011, 174 : 239 - 245
  • [32] Alumina nanoparticles modified carbon paste electrode as a new voltammetric sensor for determination of dopamine
    Pourghobadi, Roghiyeh
    Baezzat, Mohammad Reza
    IRANIAN CHEMICAL COMMUNICATION, 2018, 6 (04) : 359 - 368
  • [33] RETRACTION: Development of electrode carbon paste modified by molecularly imprinted polymer as sensor for analysis of creatinine by potentiometric (Retraction of Vol 19, Pg 1808, 2017)
    Khasanah, Miratul
    Darmokoesoemo, Handoko
    Sari, Nunung Mareta
    Kadmi, Yassine
    Elmsellem, Hicham
    Kusuma, Heri Septya
    RESULTS IN PHYSICS, 2020, 19
  • [34] Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
    Jahan Bakhsh Raoof
    Reza Ojani
    Mansureh Kolbadinezhad
    Journal of Solid State Electrochemistry, 2009, 13
  • [35] Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine
    Amini, MK
    Khorasani, JH
    Khaloo, SS
    Tangestaninejad, S
    ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) : 32 - 38
  • [36] The Performance of Molecularly Imprinted Polymers (MIPs)- Modified Carbon Paste Electrode and Its Application in Detecting Phenol
    Setiyanto, Henry
    Rahmadhani, Sri
    Sukandar, Sukandar
    Saraswaty, Vienna
    Zulfikar, Muhammad Ali
    Mufti, Nandang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (06): : 5477 - 5486
  • [37] A ferrocene/imprinted polymer nanomaterial-modified carbon paste electrode as a new generation of gate effect-based voltammetric sensor
    Alizadeh, Taher
    Akhoundian, Maedeh
    Ganjali, Mohammad Reza
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (06) : 4719 - 4727
  • [38] Studies on Zeolite Modified Electrode(Ⅰ)─Ascorbic Acid Sensor Based on Carbon Paste Electrode Containing Fe(Ⅲ)Y Zeolite
    Ming Zhu ZOU
    Hong Ding XU
    Jie LU
    Qin Hua Ru (a Department of Chemistry
    ChineseChemicalLetters, 1997, (03) : 247 - 250
  • [39] Nickel-Zeolite modified carbon paste electrode as electrochemical sensor for hydrogen peroxide
    Banafsheh Norouzi
    Ali Malekan
    Majid Moradian
    Russian Journal of Electrochemistry, 2016, 52 : 330 - 339
  • [40] Nickel-Zeolite modified carbon paste electrode as electrochemical sensor for hydrogen peroxide
    Norouzi, Banafsheh
    Malekan, Ali
    Moradian, Majid
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2016, 52 (04) : 330 - 339