Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode

被引:74
|
作者
Raoof, Jahan Bakhsh [1 ]
Ojani, Reza [1 ]
Kolbadinezhad, Mansureh [1 ]
机构
[1] Mazandaran Univ, Electroanalyt Chem Res Lab, Dept Chem, Fac Basic Sci, Babol Sar, Iran
关键词
Ferrocene; Carbon paste electrode; Glutathione; Electrocatalysis; Cyclic voltammetry; Differential pulse voltammetry; OXIDIZED GLUTATHIONE; SPECTROPHOTOMETRIC DETERMINATION; REDUCED GLUTATHIONE; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; AMPEROMETRIC SENSOR; HYDROGEN-PEROXIDE; ASCORBIC-ACID; THIOLS; OXIDATION;
D O I
10.1007/s10008-008-0690-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrocatalytic oxidation of glutathione (GSH) has been studied at the surface of ferrocene-modified carbon paste electrode (FMCPE). Cyclic voltammetry (CV), double potential step chronoamperometry, and differential pulse voltammetry (DPV) techniques were used to investigate the suitability of incorporation of ferrocene into FMCPE as a mediator for the electrocatalytic oxidation of GSH in buffered aqueous solution. Results showed that pH 7.00 is the most suitable for this purpose. In the optimum condition (pH 7.00), the electrocatalytic ability of about 480 mV can be found and the heterogeneous rate constant of catalytic reaction was calculated as k(h)' = 83 x 10(-1) cm s(-1). Also, the diffusion coefficient of glutathione, D, was found to be 3.61 x 10(-5) cm(2) s(-1). The electrocatalytic oxidation peak current of glutathione at the surface of this modified electrode was linearly dependent on the GSH concentration and the linear analytical curves were obtained in the ranges of 3.2 x 10(-5) M-1.6 x 10(-3) M and 2.2 x 10(-6) M-3.5 x 10(-3) M with cyclic voltammetry and differential pulse voltammetry methods, respectively. The detection limits (3 sigma) were determined as 1.8 x 10(-5) M and 2.1 x 10(-6) M using CV and DPV, respectively. Finally, the electrocatalytic oxidation of GSH at the surface of this modified electrode can be employed as a new method for the voltammetric determination of glutathione in real samples such as human plasma.
引用
收藏
页码:1411 / 1416
页数:6
相关论文
共 50 条
  • [1] Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
    Jahan Bakhsh Raoof
    Reza Ojani
    Mansureh Kolbadinezhad
    [J]. Journal of Solid State Electrochemistry, 2009, 13
  • [2] Sensitive and selective determination of phenylhydrazine in the presence of hydrazine at a ferrocene-modified carbon nanotube paste electrode
    Dariush Afzali
    Hassan Karimi-Maleh
    Mohammad Ali Khalilzadeh
    [J]. Environmental Chemistry Letters, 2011, 9 : 375 - 381
  • [3] Sensitive and selective determination of phenylhydrazine in the presence of hydrazine at a ferrocene-modified carbon nanotube paste electrode
    Afzali, Dariush
    Karimi-Maleh, Hassan
    Khalilzadeh, Mohammad Ali
    [J]. ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (03) : 375 - 381
  • [4] Differential pulse voltammetry determination of L-cysteine with ferrocene-modified carbon paste electrode
    Raoof, JB
    Ojani, R
    Kolbadinezhad, M
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2005, 78 (05) : 818 - 826
  • [5] Electrochemical detection of carbidopa using a ferrocene-modified carbon nanotube paste electrode
    Yaghoubian, Halimeh
    Karimi-Maleh, Hassan
    Khalilzadeh, Mohammad Ali
    Karimi, Fatemeh
    [J]. JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2009, 74 (12) : 1443 - 1453
  • [6] A zeolite modified carbon paste electrode as useful sensor for voltammetric determination of acetaminophen
    Ahmadpour-Mobarakeh, Leila
    Nezamzadeh-Ejhieh, Alireza
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 493 - 499
  • [7] Voltammetric Determination of Glutathione Using a Modified Single Walled Carbon Nanotubes Paste Electrode
    Soltani, Hossein
    Beitollahi, Hadi
    Hatefi-Mehrjardi, Abdol-Hamid
    Tajik, Somayeh
    Torkzadeh-Mahani, Masoud
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (01): : 67 - 79
  • [8] Voltammetric Sensor Based on Modified Carbon Paste Electrode for Determination of Vitamin B6
    Soltani-Nejad, Hadi
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    [J]. RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2024, 60 (06) : 478 - 485
  • [9] Alumina nanoparticles modified carbon paste electrode as a new voltammetric sensor for determination of dopamine
    Pourghobadi, Roghiyeh
    Baezzat, Mohammad Reza
    [J]. IRANIAN CHEMICAL COMMUNICATION, 2018, 6 (04) : 359 - 368
  • [10] Voltammetric Determination of Hydroxylamine Using a Ferrocene Derivative and NiO/CNTs Nanocomposite Modified Carbon Paste Electrode
    Golestanifar, Fereshteh
    Karimi-Maleh, Hassan
    Atar, Necip
    Aydogdu, Ercan
    Ertan, Bengu
    Taghavi, Mehdi
    Yola, Mehmet Lutfi
    Ghaemy, Mousa
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (07): : 5456 - 5464