Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

被引:0
|
作者
Khasanah, Miratul [1 ]
Widati, Alfa Akustia [1 ]
Severia, Nadya Maya [1 ]
Oktaviana, Citra Marantika Nur [1 ]
Puspitasari, Evrillia [1 ]
Ummah, Naftalia Wirdatul [1 ]
Alviani, Ziana [1 ]
机构
[1] Univ Airlangga, Fac Sci & Technol, Dept Chem, Campus C,Jl Dr Ir H Soekarno MERR, Surabaya 60115, Indonesia
关键词
cholesterol detection; electrometry; imprinted zeolite X; carbon paste electrode; health risk;
D O I
10.22146/ijc.99700
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10(-6)-10(-3) M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 x 10(-6) M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 mu M), precision of 96-99%, accuracy of 74-114%, sensitivity of 7.1 nA.L/mg/cm(2), and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.
引用
收藏
页码:482 / 496
页数:15
相关论文
共 50 条
  • [1] Imprinted Zeolite Modified Carbon Paste Electrode as a Potentiometric Sensor for Uric Acid
    Khasanah, Miratul
    Widati, Alfa Akustia
    Fitri, Sarita Aulia
    5TH INTERNATIONAL CONFERENCE AND WORKSHOP ON BASIC AND APPLIED SCIENCES (ICOWOBAS 2015), 2016, 1718
  • [2] Imprinted Zeolite Modified Carbon Paste Electrode as A Selective Potentiometric Sensor for Blood Glucose
    Khasanah, Miratul
    Widati, Alfa Akustia
    Handajani, Usreg Sri
    Shofiyyah, Masfah Raudlotus
    Rakhma, Sabrina Aulia
    Predianto, Herwin
    14TH JOINT CONFERENCE ON CHEMISTRY 2019, 2020, 2237
  • [3] Carbon Paste Electrode Modified Imprinted Zeolite as a Selective Sensor for Creatine Analysis by Potentiometry
    Athiroh, A.
    Fadillah, T.
    Damayanti, D. F.
    Widati, A. A.
    Abdulloh, A.
    Khasanah, M.
    12TH CONGRESS OF INDONESIAN SOC. FOR BIOCHEMISTRY AND MOLECULAR BIOLOGY IN CONJUNCTION WITH THE 2ND INT. CONF COLLABORATION SEMINAR OF CHEMISTRY AND INDUSTRY (COSCI) AND ANMICRO WORKSHOP, 2018, 2019, 217
  • [4] A zeolite modified carbon paste electrode as useful sensor for voltammetric determination of acetaminophen
    Ahmadpour-Mobarakeh, Leila
    Nezamzadeh-Ejhieh, Alireza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 49 : 493 - 499
  • [5] Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry
    Khasanah, Miratul
    Widati, Alfa Akustia
    Handajani, Usreg Sri
    Harsini, Muji
    Ilmiah, Bahrotul
    Oktavia, Irene Dinda
    INDONESIAN JOURNAL OF CHEMISTRY, 2020, 20 (06) : 1301 - 1310
  • [6] Application of Carbon Paste Electrodes Modified with Imprinted Zeolite X as Potentiometric Sensors for Amitriptyline Analysis in Pharmaceuticals
    Khasanah, Miratul
    Widati, Alfa Akustia
    Wahyuni, Ade Sukma
    Bureni, Dedy Samuel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2023, 10 (03): : 339 - 352
  • [7] Voltammetric Analysis of Oxymetazoline Hydrochloride at Zeolite - Modified Carbon Paste Electrode in Micellar Medium
    Hussien, Emad M.
    Rizk, Mohamed
    Daoud, Amira M.
    El-Eryan, Rasha Th
    ELECTROANALYSIS, 2021, 33 (07) : 1771 - 1777
  • [8] RETRACTED: Development of electrode carbon paste modified by molecularly imprinted polymer as sensor for analysis of creatinine by potentiometric (Retracted Article)
    Khasanah, Miratul
    Darmokoesoemo, Handoko
    Sari, Nunung Mareta
    Kadmi, Yassine
    Elmsellem, Hicham
    Kusuma, Heri Septya
    RESULTS IN PHYSICS, 2017, 7 : 1808 - 1817
  • [9] Selective and sensitive voltammetric sensor for methocarbamol determination by molecularly imprinted polymer modified carbon paste electrode
    Payehghadr, Mahmood
    Taherkhani, Yeganeh
    Maleki, Abbas
    Nourifard, Farzaneh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (09): : 982 - 990
  • [10] CARBON-PASTE ELECTRODE AS A SENSOR IN VOLTAMMETRIC ANALYSIS
    ULAKHOVICH, NA
    MEDYANTSEVA, EP
    BUDNIKOV, GK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 48 (06) : 682 - 694