Reliability of running gait variability measures calculated from inertial measurement units

被引:0
|
作者
Jones, Ben. D. M. [1 ,2 ]
Wheat, Jon [3 ]
Middleton, Kane [2 ]
Carey, David L. [2 ]
Heller, Ben [1 ]
机构
[1] Sheffield Hallam Univ, Sport & Phys Act Res Ctr, Olymp Legacy Pk,2 Old Hall Rd, Sheffield S9 3TY, England
[2] La Trobe Univ, Sch Allied Hlth Human Serv & Sport, Sport Performance & Nutr Res Grp, Melbourne, Vic 3086, Australia
[3] Nottingham Trent Univ, Sport & Human Performance Enhancement Res Ctr, Clifton Campus, Nottingham NG11 8NS, England
关键词
Running gait; Complexity; Regularity; Between-day reliability; Inertial measurement unit; LONG-RANGE CORRELATIONS; TIME; RUNNERS; BALANCE; INJURY; ADULTS; SPEED; STYLE; RUN;
D O I
10.1016/j.jbiomech.2025.112515
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-alpha displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (>= 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r , although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] The Reliability and Validity of Measures of Gait Variability in Community-Dwelling Older Adults
    Brach, Jennifer S.
    Perera, Subashan
    Studenski, Stephanie
    Newman, Anne B.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (12): : 2293 - 2296
  • [42] Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball
    Luteberget, Live S.
    Holme, Benjamin R.
    Spencer, Matt
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (04) : 467 - 473
  • [43] Reliability of the step phase detection using inertial measurement units: pilot study
    Sessa, Salvatore
    Zecca, Massimiliano
    Bartolomeo, Luca
    Takashima, Takamichi
    Fujimoto, Hiroshi
    Takanishi, Atsuo
    HEALTHCARE TECHNOLOGY LETTERS, 2015, 2 (02): : 58 - 63
  • [44] Estimating Movement Smoothness From Inertial Measurement Units
    Melendez-Calderon, Alejandro
    Shirota, Camila
    Balasubramanian, Sivakumar
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 8
  • [45] Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems
    Cho, Young-Shin
    Jang, Seong-Ho
    Cho, Jae-Sung
    Kim, Mi-Jung
    Lee, Hyeok Dong
    Lee, Sung Young
    Moon, Sang-Bok
    ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (06): : 872 - 883
  • [46] Functional assessment of total hip arthroplasty using inertial measurement units: Improvement in gait kinematics and association with patient-reported outcome measures
    Kaufmann, Mara
    Nueesch, Corina
    Clauss, Martin
    Pagenstert, Geert
    Eckardt, Anke
    Ilchmann, Thomas
    Stoffel, Karl
    Muendermann, Annegret
    Ismailidis, Petros
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (04) : 759 - 770
  • [47] Associations between step duration variability and inertial measurement unit derived gait characteristics
    Rantalainen, Timo
    Hart, Nicolas H.
    Nimphius, Sophia
    Wundersitz, Daniel W.
    Journal of Applied Biomechanics, 2016, 32 (04): : 401 - 406
  • [48] Associations Between Step Duration Variability and Inertial Measurement Unit Derived Gait Characteristics
    Rantalainen, Timo
    Hart, Nicolas H.
    Nimphius, Sophia
    Wundersitz, Daniel W.
    JOURNAL OF APPLIED BIOMECHANICS, 2016, 32 (04) : 401 - 406
  • [49] DUO-GAIT: A gait dataset for walking under dual-task and fatigue conditions with inertial measurement units
    Lin Zhou
    Eric Fischer
    Clemens Markus Brahms
    Urs Granacher
    Bert Arnrich
    Scientific Data, 10
  • [50] Reliability and minimum detectable change of measures of gait in children during walking and running on an instrumented treadmill
    McSweeney, Simon C.
    Reed, Lloyd F.
    Wearing, Scott C.
    GAIT & POSTURE, 2020, 75 : 105 - 108