Reliability of running gait variability measures calculated from inertial measurement units

被引:0
|
作者
Jones, Ben. D. M. [1 ,2 ]
Wheat, Jon [3 ]
Middleton, Kane [2 ]
Carey, David L. [2 ]
Heller, Ben [1 ]
机构
[1] Sheffield Hallam Univ, Sport & Phys Act Res Ctr, Olymp Legacy Pk,2 Old Hall Rd, Sheffield S9 3TY, England
[2] La Trobe Univ, Sch Allied Hlth Human Serv & Sport, Sport Performance & Nutr Res Grp, Melbourne, Vic 3086, Australia
[3] Nottingham Trent Univ, Sport & Human Performance Enhancement Res Ctr, Clifton Campus, Nottingham NG11 8NS, England
关键词
Running gait; Complexity; Regularity; Between-day reliability; Inertial measurement unit; LONG-RANGE CORRELATIONS; TIME; RUNNERS; BALANCE; INJURY; ADULTS; SPEED; STYLE; RUN;
D O I
10.1016/j.jbiomech.2025.112515
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-alpha displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (>= 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r , although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Extraction of canine gait characteristics using a mobile gait analysis system based on inertial measurement units
    Altermatt, M.
    Kalt, D.
    Blattler, P.
    Schkommodau, E.
    VETERINARY AND ANIMAL SCIENCE, 2023, 21
  • [32] Reliability testing of inertial measurement units in the analysis of physiological variables in archery
    Taha, Z.
    Musa, R. M.
    Abdullah, M. R.
    Hassan, M. H. A.
    Razman, M. A. M.
    Majeed, A. P. P. Abdul
    PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2017 (MERD), 2017, : 140 - 141
  • [33] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [34] The Effect of Footwear, Running Speed, and Location on the Validity of Two Commercially Available Inertial Measurement Units During Running
    Napier, Christopher
    Willy, Richard W.
    Hannigan, Brett C.
    McCann, Ryan
    Menon, Carlo
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 3
  • [35] Estimation of horizontal running power using foot-worn inertial measurement units
    Apte, Salil
    Falbriard, Mathieu
    Meyer, Frederic
    Millet, Gregoire P.
    Gremeaux, Vincent
    Aminian, Kamiar
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [36] Lower Limb Gait Activity Recognition Using Inertial Measurement Units for rehabilitation robotics
    Hamdi, Mohammed M.
    Awad, Mohammed I.
    Abdelhameed, Magdy M.
    Tolbah, Farid A.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2015, : 316 - 322
  • [37] Inertial Measurement Units Based Wireless Sensor Network for Real Time Gait Analysis
    Lihinikaduarachchi, Imesh
    Rajapaksha, Sajith Asanka
    Saumya, Charitha
    Senevirathne, Viraj
    Silva, Pujitha
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [38] Gait Phase Recognition Using Deep Convolutional Neural Network with Inertial Measurement Units
    Su, Binbin
    Smith, Christian
    Farewik, Elena Gutierrez
    BIOSENSORS-BASEL, 2020, 10 (09):
  • [39] BETWEEN DAY WAVEFORM RELIABILITY OF WEARABLE INERTIAL MEASUREMENT UNITS IN A CLINICAL POPULATION
    Ruder, M.
    Masood, Z.
    Kobsar, D.
    OSTEOARTHRITIS AND CARTILAGE, 2022, 30 : S145 - S145
  • [40] VALIDITY AND RELIABILITY OF INERTIAL MEASUREMENT UNITS FOR JUMP HEIGHT ESTIMATIONS: A SYSTEMATIC REVIEW
    Clemente, Filipe Manuel
    Badicu, Georgian
    Hasan, Uday Ch.
    Akyildiz, Zeki
    Pino-Ortega, Jose
    Silva, Rui
    Rico-Gonzalez, Markel
    HUMAN MOVEMENT, 2022, 23 (04) : 1 - 20