Reliability of running gait variability measures calculated from inertial measurement units

被引:0
|
作者
Jones, Ben. D. M. [1 ,2 ]
Wheat, Jon [3 ]
Middleton, Kane [2 ]
Carey, David L. [2 ]
Heller, Ben [1 ]
机构
[1] Sheffield Hallam Univ, Sport & Phys Act Res Ctr, Olymp Legacy Pk,2 Old Hall Rd, Sheffield S9 3TY, England
[2] La Trobe Univ, Sch Allied Hlth Human Serv & Sport, Sport Performance & Nutr Res Grp, Melbourne, Vic 3086, Australia
[3] Nottingham Trent Univ, Sport & Human Performance Enhancement Res Ctr, Clifton Campus, Nottingham NG11 8NS, England
关键词
Running gait; Complexity; Regularity; Between-day reliability; Inertial measurement unit; LONG-RANGE CORRELATIONS; TIME; RUNNERS; BALANCE; INJURY; ADULTS; SPEED; STYLE; RUN;
D O I
10.1016/j.jbiomech.2025.112515
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-alpha displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (>= 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r , although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Concurrent Validity Of Inertial Measurement Units To Measure Joint Angles During Gait
    Vargo, Brendal
    Franklin, Shannon
    Tometich, Nathan
    Chinworth, Susan
    Vallabhajosula, Srikant
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 557 - 558
  • [22] Wearable Inertial Measurement Units for Assessing Gait in Real-World Environments
    Renggli, David
    Graf, Christina
    Tachatos, Nikolaos
    Singh, Navrag
    Meboldt, Mirko
    Taylor, William R.
    Stieglitz, Lennart
    Schmid Daners, Marianne
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [23] Sarcopenia screening based on the assessment of gait with inertial measurement units: a systematic review
    Perez-Lasierra, Jose Luis
    Azpiroz-Puente, Marina
    Alfaro-Santafe, Jose-Victor
    Almenar-Arasanz, Alejandro-Jesus
    Alfaro-Santafe, Javier
    Gomez-Bernal, Antonio
    BMC GERIATRICS, 2024, 24 (01)
  • [24] Evaluation of inertial measurement units as a novel method for kinematic gait evaluation in dogs
    Duerr, Felix M.
    Pauls, Alexandra
    Kawcak, Chris
    Haussler, Kevin K.
    Bertocci, Gina
    Moorman, Valerie
    King, Melissa
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 475 - 483
  • [25] Measuring markers of aging and knee osteoarthritis gait using inertial measurement units
    Hafer, Jocelyn F.
    Provenzano, Seraphina G.
    Kern, Kathy L.
    Agresta, Cristine E.
    Grant, John A.
    Zernicke, Ronald F.
    JOURNAL OF BIOMECHANICS, 2020, 99
  • [26] Sparse Visual-Inertial Measurement Units Placement for Gait Kinematics Assessment
    Mallat, Randa
    Bonnet, Vincent
    Dumas, Raphael
    Adjel, Mohamed
    Venture, Gentiane
    Khalil, Mohamad
    Mohammed, Samer
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2021, 29 : 1300 - 1311
  • [27] Center of Mass Estimation for Impaired Gait Assessment Using Inertial Measurement Units
    Labrozzi, Gabrielle C.
    Warner, Holly
    Makowski, Nathaniel S.
    Audu, Musa L.
    Triolo, Ronald J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 12 - 22
  • [28] The use of inertial measurement units to assess gait and postural control following concussion
    Dugan, Eric L.
    Shilt, Jeffrey S.
    Masterson, Cara M.
    Ernest, Kristin M.
    GAIT & POSTURE, 2021, 83 : 262 - 267
  • [29] Gait evaluation using inertial measurement units in subjects with Parkinson's disease
    Zago, Matteo
    Sforza, Chiarella
    Pacifici, Ilaria
    Cimolin, Veronica
    Camerota, Filippo
    Celletti, Claudia
    Condoluci, Claudia
    De Pandis, Maria Francesca
    Galli, Manuela
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 42 : 44 - 48
  • [30] Gait data from 51 healthy participants with motion capture, inertial measurement units, and computer vision
    Lavikainen, Jere
    Vartiainen, Paavo
    Stenroth, Lauri
    Karjalainen, Pasi A.
    Korhonen, Rami K.
    Liukkonen, Mimmi K.
    Mononen, Mika E.
    DATA IN BRIEF, 2024, 56